| Literature DB >> 35742650 |
Chengju Wang1, Juan Wang1, Dan Norbäck1.
Abstract
Energy use in buildings can influence the indoor environment. Studies on green buildings, energy saving measures, energy use, fuel poverty, and ventilation have been reviewed, following the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The database PubMed was searched for articles published up to 1 October 2020. In total, 68 relevant peer-reviewed epidemiological or exposure studies on radon, biological agents, and chemicals were included. The main aim was to assess current knowledge on how energy saving measures and energy use can influence health. The included studies concluded that buildings classified as green buildings can improve health. More efficient heating and increased thermal insulation can improve health in homes experiencing fuel poverty. However, energy-saving measures in airtight buildings and thermal insulation without installation of mechanical ventilation can impair health. Energy efficiency retrofits can increase indoor radon which can cause lung cancer. Installation of a mechanical ventilation systems can solve many of the negative effects linked to airtight buildings and energy efficiency retrofits. However, higher ventilation flow can increase the indoor exposure to outdoor air pollutants in areas with high levels of outdoor air pollution. Finally, future research needs concerning energy aspects of buildings and health were identified.Entities:
Keywords: asthma; built environment; energy efficiency buildings; energy use; green buildings; health; indoor air quality; respiratory
Mesh:
Substances:
Year: 2022 PMID: 35742650 PMCID: PMC9223700 DOI: 10.3390/ijerph19127393
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 4.614
Figure 1PRISMA flow diagram of literature research.
Associations between energy-related building factors and pollutants among the 23 included exposure studies.
| No. | References | Country | Pollutant Groups | Improved Ventilation | Thermal Retrofit | Draught Proofing | Green Retrofits | Fuel Poverty | Energy Carrier |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Collignan et al. 2016 [ | France | Radon | ||||||
| 2 | Symonds et al. 2019 [ | United Kingdom | Radon | ↑ | |||||
| 3 | Meyer et al. 2019 [ | Germany | Radon | ↑ | ↑ | ||||
| 4 | Pressyanov et al. 2015 [ | Bulgaria | Radon | ↑ | ↑ | ||||
| 5 | Vasilyev et al. 2017 [ | Russia | Radon | ↑ | |||||
| 6 | Yarmoshenko et al. 2014 [ | Russia | Radon | ↑ | |||||
| 7 | Vasilyev et al. 2015 [ | Russia | Radon | ↑ | |||||
| 8 | Burghele et al. 2020 [ | Romania | Radon | ↓ | |||||
| 9 | Pigg et al. 2018 [ | United States | Radon 1, | ↓ | ↑1, ↓3 | ↑1, ↓3 | |||
| 10 | Wallner et al. 2015 [ | Austria | Radon 1, | ↓1, ↓2, ↓3 | |||||
| 11 | Du et al. 2019 [ | Finland Lithuania | Radon 1, | ↓2, ↑↓3 | ↑1 | ||||
| 12 | Hirsch et al. 2020 [ | Germany | biological agents | ↑ | |||||
| 13 | Sharpe et al. 2015 [ | United Kingdom | biological agents | ↑ | |||||
| 14 | Sharpe et al. 2016 [ | United Kingdom | biological agents | ↓ | |||||
| 15 | Spertini et al. 2010 [ | Switzerland | biological agents | ↓ | |||||
| 16 | Niculita-Hirzel et al. 2000 [ | Switzerland | biological agents | ↓ | |||||
| 17 | Coombs et al. 2018 [ | United States | biological agents | 0 | |||||
| 18 | Derbez et al. 2018 [ | France | Chemicals | ↑ | |||||
| 19 | Leivo et al. 2018 [ | Finland Lithuania | Chemicals | ↓ | ↑ | ||||
| 20 | Coombs et al. 2016 [ | United States | Chemicals | ↑↓ | |||||
| 21 | Yang et al. 2020 [ | Switzerland | Chemicals | ↑ | |||||
| 22 | Verriele et al. 2016 [ | France | Chemicals | ↓ | |||||
| 23 | Baumgartner et al. 2019 [ | China | Chemicals | ↑↓ |
↑ means increase, ↓ means decrease, ↑↓ means mixed results, 0 means no associations. 1 represents radon, 2 represents biological agents, 3 represents chemicals.
Exposure Field Studies on Radon.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Measured Exposure | Changes of Measured Exposure | Number of Households or Buildings | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Collignan et al. [ | 2016 | France | Improved insulation, ventilation and window replacement | One time measurement | Residential | Radon | 21% increase (median 147 Bq/m3) | 3233 households or 3233 buildings | Energy efficiency thermal retrofit (linked to reduced air permeability of the building envelope) can increase indoor radon concentration. |
| Symonds et al. [ | 2019 | United Kingdom | Insulation in loft and wall, double glazing | Longitudinal | Residential | Radon | Arith. Mean > 132–159.3 Bq/m3− | 470,689 households | Energy efficiency retrofit by improving insulation in loft and wall, and/or double glazing can increase radon concentrations, possibly due to increased airtightness. |
| Du et al. [ | 2019 | Finland and Lithuania | Improved insulation in wall, roof, windows or balconies | Intervention | Residential | Radon | Mean increase of 13.8 Bq/m3 (<100 Bq/m3) | 336 households or 65 buildings | In homes in Lithuania, energy efficiency retrofits without installation of mechanical ventilation increased indoor radon concentrations. |
| Pigg et al. [ | 2018 | United States | Weatherization services | Intervention | Residential | Radon | Increased by 0.14 ± 0.13 pCi/L (>100 Bq/m3 in high zone) | 514 households | Energy efficiency weatherization services (retrofits) can increase radon concentration. However, energy efficiency weatherization services with improved ventilation or ground covers can reduce radon concentration. |
| Meyer et al. [ | 2019 | Germany | Air tightness windows and insulation of outer walls | One time measurement | Residential | Radon | 40 Bq/m3 in non-refurbished vs. 69 Bq/m3 in refurbished | 150 households | Energy efficiency refurbishments of existing buildings without installation of ventilation systems can increase radon concentration, as compared to non-refurbished conventional buildings. |
| Pressyanov et al. [ | 2015 | Bulgaria | New energy-efficient windows with plastic joinery | Intervention | Residential | Radon | Rooms with radon increase was 193 Bq/m3 and rooms with no change was 45 Bq/m3 | 20 rooms or 16 buildings | Energy-efficient reconstructions with installation of new energy-efficient windows (linked to air tightness) can increase radon levels. |
| Vasilyev et al. [ | 2017 | Russia | Energy efficiency insulation | One time measurement | Residential | Radon | Arithmetic mean 38 Bq/m3 in conventional vs. 93 Bq/m3 in modern buildings | 81 buildings | Energy efficiency measures in buildings (linked to low indoor air exchange rate) can increase indoor radon concentration. |
| Yarmoshenko et al. [ | 2014 | Russia | Energy efficiency insulation | Before-after | Residential | Radon | Arithmetic mean 42 Bq/m3 in conventional vs. 133 Bq/m3 in modern buildings | 7 households or 7 buildings | Energy efficiency measures in buildings (linked to low indoor air exchange rate) can increase indoor radon concentration. |
| Vasilyev et al. [ | 2015 | Russia | Energy efficiency insulation | Before-after | Residential | Radon | Arithmetic mean 42 Bq/m3 in conventional vs. 166 Bq/m3 in modern buildings | 5 rooms or 5 buildings | Energy efficiency measures in buildings (linked to low indoor air exchange rate) can increase indoor radon concentration. |
| Burghele et al. [ | 2020 | Romania | Installation of centralized and decentralized mechanical ventilation with heat recovery | Intervention | Residential | Radon | Reduction was between 25% to 95% (Before >100 Bq/m3) | 10 households or 10 buildings | Sub-slab and sump depressurization, installation of centralized and decentralized mechanical ventilation with heat recovery can reduce radon concentrations. |
| Wallner et al. [ | 2015 | Austria | Existing mechanical ventilation and natural ventilation | Before-after | Residential | Radon | 17 Bq/m3 mechanical ventilation vs. 31 Bq/m3 natural ventilation | 123 households | Energy-efficient buildings with existing mechanical ventilation can reduce radon concentrations, as compared to conventional buildings without installation of mechanical ventilation, especially for radon. |
Exposure Field Studies on Mould Bacteria and House Dust Mites.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Measured Exposure | Changes of Measured Exposure | Number of Households | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Hirsch et al. [ | 2000 | Germany | Installation of insulated windows and central heating systems | Intervention | Residential | House dust mite Der f 1 and mould | Der f 1 in carpets 0.65 vs. 1.28, mattresses 1.56 vs. 2.40 μg/g; Aspergillus fumigatus 20 vs. 60 units/g | 98 households | Installation of insulated windows and central heating systems (linked to reduced ventilation) increased the concentration of the house dust mite allergen Der f 1 and the mould species Aspergillus fumigatus. |
| Sharpe et al. [ | 2015 | United Kingdom | Fuel poverty | Cross-sectional | Social Residential | Self-reported dampness and mould | No data | 671 households | Fuel poverty (linked to ineffective heating and ventilation practices) can increase indoor dampness and mould, regardless of the use of extractor fans. |
| Sharpe et al. [ | 2016 | United Kingdom | Type of heating, glazing, insulation levels, energy efficiency ratings | Cross-sectional | Social Residential | Self-reported allergenic mould | No data | 41 households | Energy efficiency improvement combined with increased ventilation flow rate reduced fungal contamination with Aspergillus/Penicillium mould species and |
| Spertini et al. [ | 2010 | Switzerland | Improved insulation, ventilation system with heat recovery and natural ventilation | One time measurement | Residential | Self-reported house dust mites Der f 1 | Median 67 vs. 954 ng/g in mattresses and 20 vs. 174 ng/g in carpets | 289 households or 11 buildings | Buildings designed for low energy use with installation of mechanical ventilation reduced indoor relative air humidity as well as house dust mite allergen concentration both in mattresses and in carpets, as compared to control buildings. |
| Niculita-Hirzel et al. [ | 2020 | Switzerland | Type of ventilation and energy consumption | One time measurement | Residential | Fungal | Penicillium CFUs was lower | 149 households | Installation of mechanical ventilation in buildings reduced the infiltration of outdoor fungal particles, as compared to buildings with natural ventilation only. |
| Coombs et al. [ | 2018 | United States | Green renovation with bathroom fans | Before-after | Residential | Mould | 521,826 reads from green homes vs. 726,690 fungal reads from non-green homes | 52 households | The concentration of mould in air samples and door dust samples did not differ between green and non-green homes. However, green homes had a lower concentration of mould in bed samples. |
| Du et al. [ | 2019 | Finland and Lithuania | Replacing windows and/or installation of heat recovery to the existing exhaust ventilation system | Intervention | Residential | Airborne mould and bacterial | Fungal 0.6-log; Bacterial 0.6-log in gram-positive and 0.9-log in gram-negative bacterial (reduction in cells/m2) | 336 households or 65 buildings | In homes in Finland, energy efficiency retrofits with installation of mechanical ventilation reduced indoor concentrations of airborne mould and bacterial. |
| Wallner et al. [ | 2015 | Austria | Mechanical ventilation and natural ventilation | Before-after | Residential | Mould | 84% of rooms vs. 35% rooms | 123 households | Energy-efficient buildings with installation of mechanical ventilation reduced indoor mold spore concentration, as compared to conventional buildings without installation of mechanical ventilation. |
Exposure Field Studies on Chemicals.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Measured Exposure | Changes of Measured Exposure | Number of Households or Buildings | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Derbez et al. [ | 2018 | France | Installation of ventilation system or passive stack/hybrid ventilation | Before-after | Residential | VOCs, aldehyde | Hexaldehyde: 37 vs. 17 µg/m3 in dwellings with/without flooring products | 72 households or 43 buildings | Low energy retrofit can increase the air concentration of alpha-pinene and hexaldehyde, possibly caused by the use of wood or wood-based products for the construction and insulation. |
| Du et al. [ | 2019 | Finland and Lithuania | Replacing windows and/or installation of heat recovery to the existing exhaust ventilation system | Intervention | Residential | BTEX and formaldehyde | Mean increase of 2.5 µg/m3 in BTEX | 336 households or 65 buildings | In homes in Finland, energy efficiency retrofits with existing mechanical ventilation increased indoor air concentrations of benzene, toluene, ethyl benzene and xylene (BTEX) but reduced indoor formaldehyde concentrations. |
| Leivo et al. [ | 2018 | Finland and Lithuania | Installation of heat recovery to the existing exhaust ventilation system. Improved thermal insulation in wall, roof, windows or balconies | Intervention | Residential | CO2 | Median: 775 vs. 956 PPM (1st); Median: 730 vs. 840 PPM (2nd) | 290 households or 66 buildings | In homes in Finland, energy efficiency retrofits with existing mechanical ventilation reduced CO2 concentration as compared to natural ventilation. In homes in Lithuania, improved insulation without installation of mechanical ventilation increased measured CO2 levels. |
| Coombs et al. [ | 2016 | United States | Green renovation | Intervention | Residential | Black carbon, formaldehyde | Black carbon averaging 682 vs. 2364 ng/m3; Formaldehyde 0.03 vs. 0.01 ppm | 42 households | Energy efficiency green renovation (linked to reduced ventilation) decreased indoor black carbon level in air from outdoor sources and increased indoor formaldehyde concentration. |
| Yang et al. [ | 2020 | Switzerland | Thermal retrofit of roof, walls and floors, replacement of heating system, installation of mechanical ventilation system | One time measurement | Residential | Aldehydes, VOCs | Formaldehyde 13 vs. 15; Toluene 16 vs. 26; Xylenes 1.4 vs. 5.8; Acrolein 0.4 vs. 0.6; D-limonene 7.9 vs. 11; Isobutane 3.4 vs. 10; Butane 8.8 vs. 2 (µg/m3) | 169 households | Energy efficiency thermal retrofit without installation of mechanical ventilation increased formaldehyde, aromatics, alkane, and levels of certain volatile organic compounds, as compared to new homes built with installed mechanical ventilation. |
| Verriele et al. [ | 2016 | France | Controlled ventilation systems | Before-after | School buildings | CO2 | Peak Level 1000 ppm vs. 3800–5000 ppm | 10 school buildings | Low energy school buildings combined controlled mechanical ventilation systems and an adapted ventilation schedule can reduce CO2 levels. |
| Pigg et al. [ | 2018 | United States | Weatherization services | Intervention | Residential | CO | Peak Level 35 ppm vs. 13–20 ppm | 514 households | Energy efficiency weatherization services in homes without improved ventilation or ground covers can reduce exposure to CO. |
| Wallner et al. [ | 2015 | Austria | Mechanical ventilation and natural ventilation | Before-after | Residential | CO2, TVOC, aldehydes | CO2: 1360 vs. 1830 ppm and 1280 vs. 1740 ppm; TVOC: 300 vs. 560 µg/m3; aldehydes: 32 vs. 53 µg/m3 and 18 vs. 33 µg/m3 | 123 households | Energy efficient buildings with installation of mechanical ventilation reduced indoor concentrations of CO2, TVOC, aldehydes, and improved the measured indoor air quality in homes, as compared to conventional buildings without installation of mechanical ventilation. |
| Baumgartner et al. [ | 2019 | China | Low-polluting semi gasifier cook stove with chimney, water heater and pelletized biomass fuel | Intervention | Residential | PM2.5, black carbon | PM2.5 (46%), black carbon (55%) | 205 households | An energy intervention replacing low-polluting semi gasifier cook stove in rural buildings was associated with decreased exposures to PM2.5 and black carbon in winter but higher exposures to PM2.5 and black carbon in summer, as compared to untreated homes with traditional stoves. The negative effect could be caused by increased use of semi gasifier cook stove. |
Associations between one kind of fuel poverty, improved ventilation, and energy efficiency improvements and health in all 45 selected health studies.
| No. | Reference | Thematic Group | Respiratory Health | General Health | Mental Health | Performance | Satisfaction | Cold-Related Mortality | SBS Symptoms | |
|---|---|---|---|---|---|---|---|---|---|---|
| Asthma | Other Respiratory Illnesses | |||||||||
| 1 | Garland et al. 2013 [ | Green Buildings | + | |||||||
| 2 | Singh et al. 2010 [ | Green Buildings | + | + | + | + | ||||
| 3 | Breysse et al. 2011 [ | Green Buildings | + | + | + | |||||
| 4 | Breysse et al. 2015 [ | Green Buildings | + | + | ||||||
| 5 | Hedge et al. 2013 [ | Green Buildings | + | + | + | |||||
| 6 | Hedge et al. 2014 [ | Green Buildings | + | + | + | |||||
| 7 | Gawande et al. 2020 [ | Green Buildings | 0 | |||||||
| 8 | Rudge et al. 2005 [ | Fuel Poverty | # | |||||||
| 9 | Webb et al. 2013 [ | Fuel Poverty | # | |||||||
| 10 | Sharpe et al. 2015 [ | Fuel Poverty | # | |||||||
| 11 | Poortinga et al. 2017 [ | Fuel Poverty | + | +/− | + | +/− | ||||
| 12 | Carlton et al. 2019 [ | Fuel Poverty | − | − | ||||||
| 13 | Howden-Chapman et al. 2011 [ | Fuel Poverty | + | + | + | |||||
| 14 | Howden-Chapman et al. 2007 [ | Fuel Poverty | + | + | ||||||
| 15 | Humphrey et al. 2020 [ | Fuel Poverty | + | |||||||
| 16 | Thomson et al. 2017 [ | Fuel Poverty | # | # | ||||||
| 17 | Ahrentzen et al. 2016 [ | Fuel Poverty | + | + | ||||||
| 18 | Shortt et al. 2007 [ | Fuel Poverty | + | + | ||||||
| 19 | Chapman et al. 2009 [ | Fuel Poverty | + | |||||||
| 20 | Grey et al. 2017 [ | Fuel Poverty | + | + | ||||||
| 21 | Poortinga et al. 2018 [ | Fuel Poverty | + | + | ||||||
| 22 | Pollard et al. 2019 [ | Fuel Poverty | # | |||||||
| 23 | Angelini et al. 2019 [ | Fuel Poverty | # | |||||||
| 24 | Sartini et al. 2018 [ | Fuel Poverty | + | |||||||
| 25 | Peralta et al. 2017 [ | Fuel Poverty | +/− | |||||||
| 26 | Umishio et al. 2019 [ | Fuel Poverty | # | |||||||
| 27 | López-Bueno et al. 2020 [ | Fuel Poverty | + | |||||||
| 28 | Engvall et al. 2003 [ | Cross sectional | − | |||||||
| 29 | Smedje et al. 2017 [ | Cross sectional | + | |||||||
| 30 | Norback et al. 2014 [ | Cross sectional | +/− | |||||||
| 31 | Wang et al. 2017 [ | Cross sectional | + | |||||||
| 32 | Sharpe et al. 2019 [ | Cross sectional | + | |||||||
| 33 | Sobottka et al. 1996 [ | Cross sectional | − | |||||||
| 34 | Bakke et al. 2008 [ | Cross sectional | # | |||||||
| 35 | Kennard et al. 2020 [ | Cross sectional | # | |||||||
| 36 | Wallner et al. 2017 [ | Longitudinal | + | |||||||
| 37 | Somerville et al. 2000 [ | Intervention | + | + | ||||||
| 38 | Barton et al. 2007 [ | Intervention | + | + | ||||||
| 39 | Osman et al. 2010 [ | Intervention | + | |||||||
| 40 | Wilson et al. 2013 [ | Intervention | + | + | + | |||||
| 41 | Haverinen-Shaughnessy et al. 2018 [ | Intervention | + | + | ||||||
| 42 | Wargocki et al. 2000 [ | Intervention | + | + | ||||||
| 43 | Engvall et al. 2005 [ | Intervention | 0 | |||||||
| 44 | Francisco et al. 2017 [ | Intervention | + | |||||||
| 45 | Umishio et al. 2020 [ | Intervention | + | |||||||
Remark: + mean positive result, − means negative result, +/− means mixed results, 0 means no associations, # means fuel poverty issues. SBS: sick building syndrome.
Green Building Health Studies.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Buildings | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Garland et al. [ | 2013 | United States | Green buildings with LEED Credits | Intervention | Residential | Self-reported asthma | 1 building | 18 children and adults | Green home buildings can reduce self-reported asthma symptoms. |
| Singh et al. [ | 2010 | United States | Green buildings with LEED Credits | Longitudinal | Office buildings | Absenteeism due to self-reported asthma, respiratory allergies, depression and stress, and work productivity | 2 office buildings | 263 employees | Green office buildings can improve indoor environment quality and reduce absenteeism due to self-reported asthma, respiratory allergies, depression and stress, and moreover improve work productivity. |
| Breysse et al. [ | 2011 | United States | Green efficiency renovation | Longitudinal | Residential | Self-reported asthma, and non-asthma respiratory problems, overall health | 1 building | 80 children and adults | Among adults, green efficiency renovation in homes can reduce self-reported asthma. Green efficiency renovation in homes can improve self-reported overall health and reduce non-asthmatic respiratory symptoms in adults as well as in children. |
| Breysse et al. [ | 2015 | United States | Green efficiency renovation | Intervention | Residential | Self-reported mental and general physical health | 1 building | 612 older adults | Green efficiency renovation in homes can improve mental and general physical health. |
| Hedge et al. [ | 2013 | United States | Green buildings with LEED Credits | Longitudinal | University buildings | Overall health, performance and work satisfaction | 2 university buildings | 44 employees | Green office buildings in a college campus improved health, performance and work satisfaction. |
| Hedge et al. [ | 2014 | Canada | Green buildings with LEED Credits | Longitudinal | University buildings | Overall health, performance and study satisfaction | 3 university buildings | 319 employees | Green classrooms in an university campus improved health, performance and work satisfaction. |
| Gawande et al. [ | 2020 | India | Green Office Buildings | cross-sectional | Office Buildings | SBS | 10 office buildings | 148 employees | No significant association between green buildings and sick building syndrome symptoms (SBS), compared with conventional buildings. |
Fuel Poverty Health Studies on Respiratory Symptoms.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Households | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Rudge et al. [ | 2005 | United Kingdom | Fuel poverty | Longitudinal | Residential | Winter | 220 households | 460 older adults | Fuel poverty in low-income homes can increase winter respiratory disease. |
| Webb et al. [ | 2013 | United Kingdom | Fuel poverty | Cross-sectional | Residential | Measured respiratory disease | 3763 households | 3763 older adults | Fuel poverty in low-income homes increase respiratory disease. |
| Sharpe et al. [ | 2015 | United Kingdom | Type of heating, glazing, insulation, energy efficiency ratings | Cross-sectional | Social residential | Doctor diagnosed asthma | 706 households | 944 adults | Energy efficiency improvement in social housing might increase current adult asthma. This may be due to increased exposure to physical, biological and chemical contaminants linked to inadequate heating, ventilation (fuel poverty behavior). |
| Poortinga et al. [ | 2017 | United Kingdom | Loft insulation, cavity-wall insulation, external wall insulation | Repeated cross-sectional | Social residential | General health, mental health, and social outcomes | Around 9200 households | 10,009 individuals | Energy efficiency improvements in social housing can improve respiratory symptoms. |
| Carlton et al. [ | 2019 | United States | Home ventilation rate | Cross-sectional | Residential | Respiratory symptoms | 216 households | 302 children and adults | High ventilation rates in low-income urban homes may increase chronic cough, asthma and asthma-like symptoms, probably caused by infiltration of outdoor air pollutants. |
| Howden-Chapman et al. [ | 2011 | New Zealand | Improved insulation into existing houses; more effective heating in insulated houses | Intervention | Residential | Respiratory symptoms | 1350 households; 409 households | 4407 children and adults; 409 children | Energy saving by using more effective heating in insulated low-income homes can improve health status and respiratory symptoms in children with asthma diagnosis. |
| Howden-Chapman et al. [ | 2007 | New Zealand | Installation of a standard retrofit insulation package | Intervention | Residential | Hospital admissions for respiratory conditions | 1350 households | 4407 children and adults | Energy saving by insulating existing houses in low-income communities can improve indoor environment and reduce hospital admissions for respiratory conditions. |
| Humphrey et al. [ | 2020 | United States | Home ventilation rate | Cross-sectional | Residential | Measured lung | 187 households | 253 children and adults | High infiltration rate in low-income, urban, non-smoking homes can improve lung health. |
Fuel Poverty Health Studies on General and Mental Health.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Households | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Thomson et al. [ | 2017 | 32 European Countries | Fuel poverty | Cross-sectional | Residential | General health and well-being | No data | 41,560 adults | Fuel poverty in low-income homes can reduce general health and emotional well-being. |
| Poortinga et al. [ | 2017 | United Kingdom | Loft insulation, cavity-wall insulation, external wall insulation | Repeated cross-sectional | Social residential | General health, mental health, and social outcomes | Around 9200 households | 10,009 individuals | Energy efficiency improvements in social housing can improve general health, mental health and social outcomes. However, installation of cavity wall insulation without installation of mechanical ventilation can reduce general health outcomes and social outcomes. |
| Ahrentzen et al. [ | 2016 | United States | Insulation of roof and floor, improved thermal, air conditioner heating, cooling system, new ceiling fans, new windows | Intervention | Residential | General health, emotional distress, sleep | 53 households | 57 older adults | Energy efficiency retrofits in low-income homes can improve general health, emotional distress, and sleep among the older adults. |
| Shortt et al. [ | 2007 | United Kingdom | Installation of central heating systems or improved insulation | Intervention | Residential | General health, well being | 100 households | 100 individuals | Energy efficiency intervention in fuel poverty homes can improve general health, well-being. |
| Howden-Chapman et al. [ | 2011 | New Zealand | Improved insulation into existing houses; more effective heating in insulated houses | Intervention | Residential | General health and well being | 1350 households; 409 households | 4407 children and adults; 409 children | Energy saving by improving insulation in low-income homes can improve general health and well-being and reduce hospitalization in children and adults. Energy saving by using more effective heating in insulated low-income homes can improve general health status in children. |
| Howden-Chapman et al. [ | 2007 | New Zealand | Installation of a standard retrofit insulation package | Intervention | Residential | General health and well being | 1350 households | 4407 children and adults | Energy saving by insulating existing houses in low-income communities can improve indoor environment so that improve self-reported health, wheezing, days off school and work. |
| Chapman et al. [ | 2009 | New | Installation of a standard retrofit insulation package | Intervention | Residential | General health, well being | 1350 households | 4407 children and adults | Energy saving by insulating existing houses in low-income communities can improve general health, as well as cost-benefit of general practitioner (GP) visits, hospitalizations, reduced time off work and school. |
| Grey et al. [ | 2017 | United Kingdom | External wall insulation, central heating system, and installation of gas network | Intervention | Residential | Well-being and psychosocial outcomes | 774 households | 776 individuals | Energy efficiency intervention in low-income homes can increase residential wellbeing and psychosocial-related health. |
| Poortinga et al. [ | 2018 | United Kingdom | External wall insulation, photovoltaics, solar water heating, air source heat pumps, loft/rafter insulation | Intervention | Residential | Well-being and psychosocial outcomes | 4968 households | 25,908 individuals | Energy efficiency intervention in low-income homes can improve well-being and psychosocial outcomes. |
| Pollard et al. [ | 2019 | United Kingdom | Fuel poverty | Intervention | Residential | Psychosocial outcomes | 22 households | 22 adults | Wearable telemetry (a thermometer with a low-temperature alarm) can raise awareness of the health effects of cold home among people living in fuel poverty (linked to psychosocial outcomes). |
Fuel Poverty Health Studies on Cold-related Mortality.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Households | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Angelini et al. [ | 2019 | United Kingdom | Winter fuel payment | Longitudinal | Residential | Cold-related mortality, blood pressure, fibrinogen | 11,578 households | 18,813 adults | Low indoor air temperature in low-income homes can increase systolic and diastolic blood pressure and fibrinogen levels in blood samples (linked to cold-related mortality). |
| Sartini et al. [ | 2018 | United Kingdom | Fuel poverty, types of home insulation and heating | Longitudinal | Residential | Cold-related mortality | 1006 households | 1402 older men | Lack of insulation in low-income homes can increase cold-related mortality. |
| Peralta et al. [ | 2017 | Spain | Energy efficient façade insulation retrofit | Longitudinal | Social residential | Cold-related mortality | 2552 households | 2552 individuals | Energy efficient façade insulation retrofit in public housing can reduce cold-related mortality in women, but can increase cold-related total mortality in men. The health outcome for the gender difference is unclear. |
| Umishio et al. [ | 2019 | Japan | Low insulation in cold homes | Cross-sectional | Residential | Blood pressure | 1840 households | 2900 adults | Low indoor air temperature was higher associated with blood pressure and hypertension (linked to cold-related mortality). |
| López-Bueno et al. [ | 2020 | Spain | Heating systems | Longitudinal | Residential | Cold-related mortality | No data | No data | Districts with higher homes without a heating system had cold-related mortality. |
Cross-sectional Health Studies.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Buildings or Households | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Engvall et al. [ | 2003 | Sweden | Type of ventilation and heating system, heat pumps, reconstruction and energy-saving measures | Cross-sectional | Residential | Sick building syndrome (SBS) symptoms | 231 buildings | 3241 adults | In multi-family buildings, lack of a mechanical ventilation system and use of direct electric radiators were associated with increased prevalence of SBS-related symptoms. Major reconstruction and multiple sealing in multi-family buildings were associated with increased prevalence of SBS-related symptoms. |
| Smedje et al. [ | 2017 | Sweden | Type of ventilation system and insulation level | Cross-sectional | Residential | Sick building syndrome (SBS) symptoms | 605 buildings | 1160 adults | In single-family buildings, a lower U-value (higher insulation level) was associated with less SBS symptoms. |
| Norback et al. [ | 2014 | Sweden | Type of ventilation and energy use for heating | Cross-sectional | Residential | Doctor’s diagnosed asthma, allergy and self-reported pollen allergy, eczema | 472 buildings | 7554 adult | Multi-family buildings with balanced ventilation systems (supply/exhaust ventilation) had a higher prevalence of doctor diagnosed allergy, as compared to buildings with exhaust ventilation only. Buildings using more energy for heating were associated with less pollen allergy and eczema. |
| Wang et al. [ | 2017 | Sweden | Type of ventilation and degree of insulation | Cross-sectional | Residential | Doctors’ diagnosed asthma, self-reported asthma | 605 buildings | 1160 adults | Higher air exchange rate in the single-family residential homes was associated with less current asthma symptoms. |
| Sharpe et al. [ | 2019 | United Kingdom | Energy efficiency ratings | Cross-sectional | Residential | Asthma, chronic obstructive pulmonary disease, cardiovascular disease | No data | No data | Reduced home ventilation rates were associated with more asthma disease. Homes with more energy efficiency improvements may were associated with more admission rates for respiratory and cardiovascular diseases, possibly caused by reduced home ventilation flow rate. Energy efficiency measures can improve health outcomes, especially chronic respiratory illness. |
| Sobottka et al. [ | 1996 | Germany | New windows and door, improved insulation and heating system | Cross-sectional | Residential | Sick building syndrome (SBS) symptoms | 52 buildings | No data | Energy saving by installing new air tightness windows and door in homes was associated with more SBS-related health complaints. This may be due to fuel poverty behavior by not airing their flats sufficiently. |
| Bakke et al. [ | 2008 | Norway | Lower air temperature | Cross-sectional | University buildings | Tear film stability, nasal patency | 4 university buildings | 173 employees | Lower air temperature in buildings at a university campus was associated with less tear film stability and more health problems. |
| Kennard et al. [ | 2020 | United Kingdom | Space heating energy use | Cross-sectional | Residential | Cold-mortality | 77,762 households | 77,762 adults | Higher thermal variety (linked to lower domestic demand temperatures) was associated with less morbidities related to cold-mortality. |
Longitudinal Health Studies.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Buildings | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Wallner et al. [ | 2017 | Austria | Mechanical ventilation and natural ventilation | Longitudinal | Residential | General health and dry eye symptoms | 123 buildings | 575 children and adults | Energy efficient buildings combined with installation of mechanical ventilation can improve self-reported health but increase dry eye symptoms, as compared to conventional buildings with natural ventilation only. |
Intervention Health Studies.
| Author | Year | Country | Energy Aspects | Type of Study | Type of Buildings | Type of Health Variables | Number of Buildings or Households | Number of Subjects | Main Results |
|---|---|---|---|---|---|---|---|---|---|
| Somerville et al. [ | 2000 | United Kingdom | the installation of central heating systems | Intervention | Residential | Respiratory symptoms | 59 households | 72 children with diagnosed asthma | Energy efficiency intervention in homes reduced respiratory symptoms, and reduced missed school days due to asthma in children with diagnosed asthma. |
| Barton et al. [ | 2007 | United Kingdom | Central heating systems, ventilation, rewiring, insulation, and re-roofing | Intervention | Social residential | Asthma, non-asthma-related respiratory disease | 119 households | 480 children and adults | Energy efficiency intervention in social housing reduced asthma symptoms, and non-asthmatic respiratory disease. |
| Osman et al. [ | 2010 | United Kingdom | Central heating systems, installation of loft, under-floor and cavity wall insulation | Intervention | Residential | Diagnosed chronic obstructive pulmonary disease (COPD) | 178 households | 178 older adults with COPD | Energy efficiency intervention in homes can improve respiratory health for elderly COPD patients. |
| Wilson et al. [ | 2013 | United States | Insulation, heating equipment and ventilation improvements | Intervention | Residential | Sinusitis, general health, satisfaction | 248 households | 323 children and adults | Energy efficiency retrofits work in homes can improve sinusitis, general health, satisfaction. |
| Haverinen-Shaughnessy et al. [ | 2018 | Finland and Lithuania | Installation of heat recovery to the existing exhaust ventilation system. Improved thermal insulation in wall, roof, windows or balconies | Intervention | Residential | Respiratory symptoms | 66 buildings | 283 individuals | Energy efficiency retrofits in homes can improve occupant satisfaction with daily noise nuisance, upper respiratory symptoms, and reduce absence from school or from work due to respiratory infections. |
| Wargocki et al. [ | 2000 | Denmark | different ventilation rates | Intervention | Office building | Sick building syndrome (SBS) symptoms, work productivity | 1 office building | 30 female employees | Improved mechanical ventilation rate in office building improve SBS symptoms, work productivity, and perceived indoor air quality. |
| Engvall et al. [ | 2005 | Sweden | different ventilation rates | Intervention | Residential | General health | 1 building | 44 adults | Energy saving by reducing ventilation flow to below 0.5 ACH could impair perceived air quality but did not influence SBS. |
| Francisco et al. [ | 2017 | United States | Weatherization services | Intervention | Residential | General health | 72 households | 178 children and adults | Energy efficiency retrofits can improve self-reported health. |
| Umishio et al. [ | 2020 | Japan | installation of outer walls, floor and/or roof insulation and replacement of windows | Intervention | Residential | Blood pressure | 1009 households | 1685 adults | Energy efficiency insulation retrofitting in homes can reduce home blood pressure and reduce morning home systolic blood pressure of hypertensive patients. |
Associations between energy factors and any health outcomes among all 45 selected health studies.
| No. | References | Energy Efficiency Improvements (at Least Two Measures) | Green Buildings | More Effective Heating | Thermal Insulation | Draught Proofing | Higher Ventilation Rate | Installation of Mechanical Ventilation |
|---|---|---|---|---|---|---|---|---|
| 1 | Garland et al. 2013 [ | + | ||||||
| 2 | Singh et al. 2010 [ | + | ||||||
| 3 | Breysse et al. 2011 [ | + | ||||||
| 4 | Breysse et al. 2015 [ | + | ||||||
| 5 | Hedge et al. 2013 [ | + | ||||||
| 6 | Hedge et al. 2014 [ | + | ||||||
| 7 | Gawande et al. 2020 [ | + | ||||||
| 8 | Poortinga et al. 2017 [ | + | − | |||||
| 9 | Carlton et al. 2019 [ | − | ||||||
| 10 | Howden-Chapman et al. 2011 [ | + | + | |||||
| 11 | Howden-Chapman et al. 2007 [ | + | ||||||
| 12 | Humphrey et al. 2020 [ | + | ||||||
| 13 | Ahrentzen et al. 2016 [ | + | ||||||
| 14 | Shortt et al. 2007 [ | + | + | |||||
| 15 | Chapman et al. 2009 [ | + | ||||||
| 16 | Grey et al. 2017 [ | + | ||||||
| 17 | Poortinga et al. 2018 [ | + | ||||||
| 18 | Sartini et al. 2018 [ | + | ||||||
| 19 | Peralta et al. 2017 [ | +/− | ||||||
| 20 | López-Bueno et al. 2020 [ | + | ||||||
| 21 | Engvall et al. 2003 [ | + | − | + | ||||
| 22 | Smedje et al. 2017 [ | + | ||||||
| 23 | Norback et al. 2014 [ | + | ||||||
| 24 | Wang et al. 2017 [ | + | ||||||
| 25 | Sharpe et al. 2019 [ | − | ||||||
| 26 | Sobottka et al. 1996 [ | − | ||||||
| 27 | Wallner et al. 2017 [ | + | ||||||
| 28 | Somerville et al. 2000 [ | + | ||||||
| 29 | Barton et al. 2007 [ | + | ||||||
| 30 | Osman et al. 2010 [ | + | ||||||
| 31 | Wilson et al. 2013 [ | + | ||||||
| 32 | Haverinen-Shaughnessy et al. 2018 [ | + | ||||||
| 33 | Wargocki et al. 2000 [ | + | ||||||
| 34 | Engvall et al. 2005 [ | + | ||||||
| 35 | Francisco et al. 2017 [ | + | ||||||
| 36 | Umishio et al. 2020 [ | + | ||||||
| Positive associations (+) | 8 | 7 | 6 | 9 | 4 | 1 | ||
| Negative associations (−) | 1 | 3 | 1 | |||||
| Mixed results (+/−) | 1 | |||||||
Remark: + mean positive result, − means negative result, +/− means mixed results.