Literature DB >> 10696861

House-dust-mite allergen concentrations (Der f 1) and mold spores in apartment bedrooms before and after installation of insulated windows and central heating systems.

T Hirsch1, M Hering, K Bürkner, D Hirsch, W Leupold, M L Kerkmann, E Kuhlisch, L Jatzwauk.   

Abstract

BACKGROUND: It has been hypothesized that changes in heating systems and insulation of homes in developed countries have generated an indoor climate favorable to organisms that excrete allergens inducing sensitization and allergic disease. The purpose of this study was to determine the influence of the installation of highly insulated windows and central heating systems on indoor climate, and mite-allergen (Der f 1) and mold spore concentrations.
METHODS: The bedrooms of 98 apartments were examined before and 7 months (mean) after installation of insulated windows and central heating systems. The air-exchange rate, temperature, and humidity were measured. In settled dust on carpets and mattresses, the number of colony-forming mold spores and the Der f 1 concentration were determined. The inhabitants completed a questionnaire about their lifestyles and housing conditions.
RESULTS: The air-exchange rate decreased from geometric mean 0.73 to 0.52 per hour (P=0.029). Temperature (mean 13.4 vs 17.5 degrees C, P<0.001), and absolute humidity (mean 4.6 g vs 6.2 g H2O/kg air, P<0.001) increased. Relative humidity remained nearly unchanged (mean 47.6 vs 49.1%). Der f 1 concentrations on carpets (geometric mean 0.65 vs 1.28 microg/g dust, P < 0.001) and mattresses (geometric mean 1.56 vs 2.40 microg/g, P=0.002) increased. Among the fungi that were analyzed, only the thermotolerant species Aspergillus fumigatus increased (geometric mean 20 vs. 60 colony-forming units/g carpet dust, P = 0.02).
CONCLUSIONS: The findings of this study suggest that the installation of insulated windows and central heating systems is associated with an increase of Der f 1 concentrations in carpet and mattress dust and of A. fumigatus in carpet dust in apartment bedrooms.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10696861     DOI: 10.1034/j.1398-9995.2000.00250.x

Source DB:  PubMed          Journal:  Allergy        ISSN: 0105-4538            Impact factor:   13.146


  7 in total

1.  The influence of Schizophyllum commune on asthma severity.

Authors:  Haruhiko Ogawa; Masaki Fujimura; Yasuo Takeuchi; Koichi Makimura
Journal:  Lung       Date:  2011-10-18       Impact factor: 2.584

2.  Environmental assessment and exposure control of dust mites: a practice parameter.

Authors:  Jay Portnoy; Jeffrey D Miller; P Brock Williams; Ginger L Chew; J David Miller; Fares Zaitoun; Wanda Phipatanakul; Kevin Kennedy; Charles Barnes; Carl Grimes; Désirée Larenas-Linnemann; James Sublett; David Bernstein; Joann Blessing-Moore; David Khan; David Lang; Richard Nicklas; John Oppenheimer; Christopher Randolph; Diane Schuller; Sheldon Spector; Stephen A Tilles; Dana Wallace
Journal:  Ann Allergy Asthma Immunol       Date:  2013-12       Impact factor: 6.347

3.  National Athletic Trainers' Association position statement: management of asthma in athletes.

Authors:  Michael G Miller; John M Weiler; Robert Baker; James Collins; Gilbert D'Alonzo
Journal:  J Athl Train       Date:  2005 Jul-Sep       Impact factor: 2.860

4.  Skin test reactivity to indoor allergens correlates with asthma severity in jeddah, saudi arabia.

Authors:  Emad A Koshak
Journal:  Allergy Asthma Clin Immunol       Date:  2006-03-15       Impact factor: 3.406

5.  Asthma, allergy and eczema among adults in multifamily houses in Stockholm (3-HE study)--associations with building characteristics, home environment and energy use for heating.

Authors:  Dan Norbäck; Erik Lampa; Karin Engvall
Journal:  PLoS One       Date:  2014-12-05       Impact factor: 3.240

Review 6.  A Systematic Review of Associations between Energy Use, Fuel Poverty, Energy Efficiency Improvements and Health.

Authors:  Chengju Wang; Juan Wang; Dan Norbäck
Journal:  Int J Environ Res Public Health       Date:  2022-06-16       Impact factor: 4.614

Review 7.  Linking public health, housing, and indoor environmental policy: successes and challenges at local and federal agencies in the United States.

Authors:  David E Jacobs; Tom Kelly; John Sobolewski
Journal:  Environ Health Perspect       Date:  2007-01-25       Impact factor: 9.031

  7 in total