Literature DB >> 15737154

Sick building syndrome and perceived indoor environment in relation to energy saving by reduced ventilation flow during heating season: a 1 year intervention study in dwellings.

K Engvall1, P Wickman, D Norbäck.   

Abstract

UNLABELLED: Ventilation in Scandinavian buildings is commonly performed by means of a constant flow ventilation fan. By using a regulated fan, it is possible to make a seasonal adjustment of outdoor ventilation flow. Energy saving can be achieved by reducing the mechanical ventilation flow during the heating season, when natural ventilation driven by temperature differences between outdoor and indoor is relatively high. This ventilation principle has been called 'seasonally adapted ventilation (SAV)'. The aim was to study if a 25-30% reduction of outdoor ventilation flow during heating season influenced sick building syndrome (SBS) and the perception of the indoor environment. This was done in a 1-year cross-over intervention study in 44 subjects in a multi-family building. During the first heating season (November to April), one part of the building (A) got a reduced flow during the heating season [0.4-0.5 air exchanges per hour (ACH)] while the other part (B) had constant flow (0.5-0.8 ACH). The next heating season, part A got constant flow, while part B got reduced ventilation flow. Reduced ventilation increased the relative air humidity by 1-3% in the living room (mean 30-37% RH), 1-5% in the bathroom (mean 48-58% RH) during heating season. The room temperature increased 0.1-0.3 degrees C (mean 20.7-21.6 degrees C), mean carbon dioxide (CO2) concentration in the bedroom increased from 920 to 980 p.p.m. at reduced flow. The indoor air quality was perceived as poorer at reduced outdoor airflow, both in the bedroom and in the apartment as a whole. There was a significant increase of stuffy odor (P = 0.05) at reduced outdoor airflow and the indoor air quality was perceived as poorer, both in the bedroom (P = 0.03) and in the apartment as a whole (P = 0.04). No significant influence on SBS symptoms or specific perceptions such as odors, draught, temperature, air dryness or stuffy air could be detected. In conclusion, reducing the ventilation flow in dwellings to a level below the current Swedish ventilation standard (0.5 ACH) may cause a perception of impaired air quality. Technical measurements could only demonstrate a minor increase of indoor temperature, relative air humidity, and bedroom CO2 concentration. This illustrates that it is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. PRACTICAL IMPLICATIONS: It is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. Reduction of outdoor airflow in dwellings below the current ventilation standard of 0.5 ACH may lead to a perception of impaired air quality, despite only a minor increase of bedroom CO2-concentration.

Entities:  

Mesh:

Year:  2005        PMID: 15737154     DOI: 10.1111/j.1600-0668.2004.00325.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  10 in total

1.  Carbon dioxide (CO2) demand-controlled ventilation in university computer classrooms and possible effects on headache, fatigue and perceived indoor environment: an intervention study.

Authors:  Dan Norbäck; Klas Nordström; Zhuohui Zhao
Journal:  Int Arch Occup Environ Health       Date:  2012-03-16       Impact factor: 3.015

2.  Analysis of the impact of a fresh air system on the indoor environment in office buildings.

Authors:  Run Ping Niu; Xiaoyi Chen; Hua Liu
Journal:  Sustain Cities Soc       Date:  2022-05-11       Impact factor: 10.696

3.  Absolute humidity modulates influenza survival, transmission, and seasonality.

Authors:  Jeffrey Shaman; Melvin Kohn
Journal:  Proc Natl Acad Sci U S A       Date:  2009-02-09       Impact factor: 11.205

4.  Relationship between humidity and influenza A viability in droplets and implications for influenza's seasonality.

Authors:  Wan Yang; Subbiah Elankumaran; Linsey C Marr
Journal:  PLoS One       Date:  2012-10-03       Impact factor: 3.240

5.  Effect of Traffic Exposure on Sick Building Syndrome Symptoms among Parents/Grandparents of Preschool Children in Beijing, China.

Authors:  Linyan Li; Gary Adamkiewicz; Yinping Zhang; John D Spengler; Fang Qu; Jan Sundell
Journal:  PLoS One       Date:  2015-06-18       Impact factor: 3.240

6.  Odors and sensations of humidity and dryness in relation to sick building syndrome and home environment in Chongqing, China.

Authors:  Juan Wang; Baizhan Li; Qin Yang; Wei Yu; Han Wang; Dan Norback; Jan Sundell
Journal:  PLoS One       Date:  2013-08-26       Impact factor: 3.240

Review 7.  Relative humidity in droplet and airborne transmission of disease.

Authors:  Anže Božič; Matej Kanduč
Journal:  J Biol Phys       Date:  2021-02-10       Impact factor: 1.560

Review 8.  A Systematic Review of Associations between Energy Use, Fuel Poverty, Energy Efficiency Improvements and Health.

Authors:  Chengju Wang; Juan Wang; Dan Norbäck
Journal:  Int J Environ Res Public Health       Date:  2022-06-16       Impact factor: 4.614

9.  School environment as predictor of teacher sick leave: data-linked prospective cohort study.

Authors:  Jenni Ervasti; Mika Kivimäki; Ichiro Kawachi; S V Subramanian; Jaana Pentti; Tuula Oksanen; Riikka Puusniekka; Tiina Pohjonen; Jussi Vahtera; Marianna Virtanen
Journal:  BMC Public Health       Date:  2012-09-11       Impact factor: 3.295

10.  Concentrations of Formic Acid, Acetic Acid, and Ammonia in Newly Constructed Houses.

Authors:  Norimichi Suzuki; Hiroko Nakaoka; Akifumi Eguchi; Masamichi Hanazato; Yoshitake Nakayama; Kayo Tsumura; Kohki Takaguchi; Kazunari Takaya; Emiko Todaka; Chisato Mori
Journal:  Int J Environ Res Public Health       Date:  2020-03-16       Impact factor: 3.390

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.