Literature DB >> 11089327

The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity.

P Wargocki1, D P Wyon, J Sundell, G Clausen, P O Fanger.   

Abstract

Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.

Entities:  

Mesh:

Year:  2000        PMID: 11089327     DOI: 10.1034/j.1600-0668.2000.010004222.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  40 in total

1.  Improving the health of workers in indoor environments: priority research needs for a national occupational research agenda.

Authors:  Mark J Mendell; William J Fisk; Kathleen Kreiss; Hal Levin; Darryl Alexander; William S Cain; John R Girman; Cynthia J Hines; Paul A Jensen; Donald K Milton; Larry P Rexroat; Kenneth M Wallingford
Journal:  Am J Public Health       Date:  2002-09       Impact factor: 9.308

Review 2.  Sick building syndrome.

Authors:  P S Burge
Journal:  Occup Environ Med       Date:  2004-02       Impact factor: 4.402

3.  Implementation of multivariate linear mixed-effects models in the analysis of indoor climate performance experiments.

Authors:  Kasper L Jensen; Henrik Spiild; Jørn Toftum
Journal:  Int J Biometeorol       Date:  2011-02-11       Impact factor: 3.787

4.  The Impact of Working in a Green Certified Building on Cognitive Function and Health.

Authors:  Piers MacNaughton; Usha Satish; Jose Guillermo Cedeno Laurent; Skye Flanigan; Jose Vallarino; Brent Coull; John D Spengler; Joseph G Allen
Journal:  Build Environ       Date:  2016-11-25       Impact factor: 6.456

5.  Indoor Air Quality Assessment Using a CO2 Monitoring System Based on Internet of Things.

Authors:  Gonçalo Marques; Cristina Roque Ferreira; Rui Pitarma
Journal:  J Med Syst       Date:  2019-02-07       Impact factor: 4.460

6.  Environmental Perceptions and Health before and after Relocation to a Green Building.

Authors:  Piers MacNaughton; John Spengler; Jose Vallarino; Suresh Santanam; Usha Satish; Joseph Allen
Journal:  Build Environ       Date:  2016-05-09       Impact factor: 6.456

7.  Human symptom responses to bioeffluents, short-chain carbonyls/acids, and long-chain carbonyls in a simulated aircraft cabin environment.

Authors:  C P Weisel; N Fiedler; C J Weschler; P A Ohman-Strickland; K R Mohan; K McNeil; D R Space
Journal:  Indoor Air       Date:  2017-06-26       Impact factor: 5.770

8.  Indoor environment in dwellings, asthma, allergies, and sick building syndrome in the Swedish population: a longitudinal cohort study from 1989 to 1997.

Authors:  B Sahlberg; Y-H Mi; D Norbäck
Journal:  Int Arch Occup Environ Health       Date:  2009-07-19       Impact factor: 3.015

Review 9.  Indoor mold, toxigenic fungi, and Stachybotrys chartarum: infectious disease perspective.

Authors:  D M Kuhn; M A Ghannoum
Journal:  Clin Microbiol Rev       Date:  2003-01       Impact factor: 26.132

10.  Impact of 2013 south Asian haze crisis: study of physical and psychological symptoms and perceived dangerousness of pollution level.

Authors:  Roger C Ho; Melvyn W Zhang; Cyrus S Ho; Fang Pan; Yanxia Lu; Vijay K Sharma
Journal:  BMC Psychiatry       Date:  2014-03-19       Impact factor: 3.630

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.