Literature DB >> 35714149

Practicable performance-based outcome measures of trunk muscle strength and their measurement properties: A systematic review and narrative synthesis.

Shouq Althobaiti1,2, Alison Rushton3, Ahmad Aldahas1, Deborah Falla1, Nicola R Heneghan1.   

Abstract

INTRODUCTION: The evaluation of muscle strength is frequently used as part of the physical examination process, with decreased trunk muscle strength reported in individuals with spinal disorders (e.g., low back pain). Access to practicable performance-based outcome measures (PBOM) to monitor patients' progress in spinal rehabilitation is essential. Knowledge of the psychometric properties of the available practicable PBOM for trunk strength evaluation is therefore needed to inform practitioners and further research.
OBJECTIVE: To synthesise evidence on the measurement properties of practicable measures of trunk muscle strength in adults with and without musculoskeletal pain.
METHODS: Following a published and registered protocol [PROSPERO CRD42020167464], databases were searched from the database inception date up to 30th of June 2021. Citations and grey literature were also searched. Eligibility criteria comprised: 1) studies which examined the psychometric properties of the trunk strength outcome measures, 2) included adults ≥ 18 years, either asymptomatic or with spinal musculoskeletal pain. Non-English language studies were excluded. Two independent reviewers evaluated the quality and synthesized the data from included studies according to the COnsensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. The overall quality of evidence was evaluated using a modified Grading of Recommendations Assessment Development and Evaluation (GRADE).
RESULTS: From 34 included studies, 15 different PBOMs were identified that have been investigated for reliability and validity, none evaluated responsiveness. In asymptomatic individuals, high quality evidence supports intra-rater reliability of digital-loading cells and moderate quality evidence supports the criterion validity of the hand-held dynamometer. Very low quality evidence exists for the reliability and validity estimates of testing tools among individuals with spinal pain.
CONCLUSIONS: Findings underpin a cautious recommendation for the use of practicable PROMs to evaluate muscle strength in individuals with spinal pain in clinical practice due to the level of evidence and the heterogeneity of the protocols used. Further high quality research to explore the psychometric properties of the practicable PBOMs with detailed methodology is now needed.

Entities:  

Mesh:

Year:  2022        PMID: 35714149      PMCID: PMC9205516          DOI: 10.1371/journal.pone.0270101

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.752


Introduction

Spinal musculoskeletal conditions are common, accounting for 21% of all causes of global disability [1]. Low back pain (LBP) and neck pain remain the two most significant causes of musculoskeletal health burden and the leading cause of long-term disability globally [2]. The management of spinal musculoskeletal conditions places an enormous economic burden on health care services worldwide [3]. In the United Kingdom for instance, LBP costs the National Health Service (NHS) around £1 billion per year [4]. The stability and mobility of the spine and extremities during functional activities depends on the activity of the trunk muscles [5, 6]. Studies have reported a link between trunk muscle weakness and spinal disorders [7-10], excessive spinal curves [11] and lower limb injuries [12]. The National Institute for Health and Care Excellence (NICE) guidelines (2016) for LBP recommend exercise programs including strengthening exercises as a clinical and cost-effective management approach [13]. Evidence supports that individual with spinal musculoskeletal conditions may benefit from strengthening exercises directed towards the trunk muscles [14, 15]. Therefore, it is essential to identify practicable Performance-based outcome measures (PBOM) of trunk muscle strength to evaluate and inform patient progression [16] and document the efficacy of rehabilitation programmes [17]. Trunk muscle strength testing is an essential part of a patient examination process, with several PBOM being used in clinical practice and research, including isokinetic dynamometers (ID), iso-station dynamometers [18], hand-held dynamometers (HHD) and manual muscle testing [19]. PBOM need to exhibit a sufficient psychometric property to accurately reflect a patient’s status and guide clinical decision making [20]. Several reviews have evaluated different PBOM of trunk muscle strength, their usefulness in routine clinical practice and to determine the hierarchy of strength values of trunk movements, from strongest to weakest, yet with little consideration of their psychometric properties [18, 21, 22]. The isokinetic and iso-station dynamometers are considered the gold standard for trunk muscle strength testing with the psychometric properties of the ID having been reviewed extensively in the literature [7, 23, 24] and acceptable levels of reliability (ICC > 0.70) and validity established. However, the ID is expensive costing around $40,000 [25], and testing multiple joints is time-consuming [26]. Moreover, with the limited portability makes the ID impractical for routine clinical testing [27]. More practical and inexpensive tools are therefore needed [3]. Thus far no evidence has summarised the psychometric properties of practicable PBOM of trunk muscle strength. The aim of this review is to evaluate the psychometric properties of practicable PBOM of trunk muscle strength.

Methods

Protocol and registration

A systematic review was designed in line with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) methodology for systematic reviews, and was conducted according to a registered [PROSPERO CRD42020167464] and published protocol [28]. Review reporting adheres to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist (PRISMA) [29] (.

Eligibility criteria

Eligibility criteria were based on; sample, phenomenon of interest, design, evaluation, research (SPIDER) search concept tool [30] as detailed in .

Box 1. Eligibility criteria

Inclusion criteria

S- Sample: Adults [aged ≥18 years] who are either athletic, healthy, or experiencing any spinal musculoskeletal conditions (MSK) were eligible. MSK conditions include any condition that affects the spinal bones, joints, muscles, and associated tissues such as ligaments and tendons according to the International Classification of Diseases [31] (e.g., neck pain, thoracic spine pain, low back pain (LBP), arthritis, osteoporosis, scoliosis. etc.). PI- Phenomenon of Interest: All practical PBOM of trunk muscle strength for use in a clinical or field-based setting, including manual, functional and mechanical methods. D-Design: Observational studies including cross-sectional study design were included. E- Evaluation: The psychometric properties based on the COSMIN Taxonomy of the clinical-based trunk strength outcome measures COSMIN taxonomy encompasses the definitions of the three main domains: reliability, validity and responsiveness [32] (S2 Table). R-Research type: Quantitative

Exclusion criteria

Studies published in languages other than English.

Information sources

The lead author (SA) conducted searches using subject headings and free text from relevant keywords identified during the scoping search as well as COSMIN recommended filters for retrieving studies on measurement properties. The following databases were searched from the database inception date up to 30th June 2021: CINAHL and SPORTDiscuss (via) EBSCO interface, MEDLINE and EMBASE (through) Ovid interface, Web of Science and Pedro. Hand searching through checking reference lists of the included studies and grey literature searches including British National Bibliography and Open Grey were carried out.

Search strategy

The search strategy was designed drawing on subject and methodological expertise of co-authors (NRH, AR and DF) and a specialist librarian. The full search strategy is described in the published protocol [28]. The following search terms were used to search in the MEDLINE database at title, abstract and the full text also, and then it was adapted for the other databases: “Trunk musc* strength”, “Trunk musc* power”, “Torso strength.”, (core strength or core power or core torque). Search filters designed by COSMIN such as (reliab* or unreliab* or valid* or coefficient or homogeneity or homogeneous or internal consistency). were also used when appropriate. MEDLINE full search string highlighted in (.

Selection process

After removing duplicates using the EndNote V. X9 (Clarivate Analytics), two independent reviewers (SA, AA) screened the titles and abstracts of all identified articles using the pre-identified eligibility criteria and categorising articles into ‘include’, ‘unsure’ (need full text) and ‘exclude’. The full text of the potentially relevant articles was retrieved and screened; articles were included if both reviewers reached a consensus on eligibility. A third reviewer was available to resolve any disagreements.

Data collection process and data items

Both reviewers (SA, AA) independently extracted data from the included studies using a piloted standardised form. Data items extracted from individual studies were information regarding study characteristics, study setting, characteristics of the population, PBOM of trunk muscle strength, type of muscle contraction measured, measurement procedure, measurement properties; reliability (test-retest); (inter-rater); or (intra-rater), measurement error, validity including both criterion and construct validity, and the responsiveness, statistical methods used and results.

Risk of bias assessment

As per the protocol [28], the COSMIN risk of bias (ROB) checklist for systematic reviews was implemented to evaluate the ROB of included studies [31]. Even though the checklist was originally designed for patient reported outcome measures, it has been recommended for adaptation and to evaluate the psychometric properties of other measures including PBOM [32]. Two reviewers (SA, AA) independently evaluated the ROB and rated each item as either ‘very good’, ‘adequate’, ‘doubtful’ or ‘inadequate’ quality [33]. The overall ROB of each measurement property was subsequently rated based on ‘the worst score counts principle’ [33].

Data synthesis

A meta-analysis was not possible due to the heterogeneity across studies in population, measurement tools and methods of data analysis. Accordingly, a narrative synthesis was conducted in line with the COSMIN guidelines [32]. Following the ROB assessment, each outcome measure was then independently rated against COSMIN pre-determined criteria for good measurement properties [34]. Two reviewers independently synthesised the results per group (either asymptomatic or with spinal pain) and pooled the results for each measurement property (reliability, validity or responsiveness) per outcome measure. The results were rated against the COSMIN updated criteria for good measurement properties as; sufficient ‘+’, insufficient ‘-’, inconsistent ‘±’ or indeterminate ‘?’ [2]. Based on COSMIN methodology, the results were considered as sufficient (+) when intraclass correlation coefficient (ICC) or where weighted Kappa for relative reliability was ≥0.70. For absolute reliability, the smallest detectable change (SDC) or limits of agreement (LoA) value was less than the minimal important change (MIC) [32]. For construct validity the results needed to align with the hypothesis defined by the review team; if no hypothesis was identified then the evidence was not graded, as per COSMIN recommendation [32]. With regard to the criterion validity, results were considered of sufficient validity if the correlation with a known gold standard was ≥ 0.70 or AUC ≥ 0.70, and the results needed to be in accordance with the hypothesis or AUC ≥ 0.70 to be considered of sufficient responsiveness. If the ICC, MIC, weighted Kappa, correlations, or hypothesis were not reported or not defined then the results were rated as indeterminate. The overall level of evidence was then graded by each reviewer independently based on the modified Grading of Recommendations Assessment, Development, and Evaluation [GRADE] approach for systematic reviews where ratings were made as per ‘high’, ‘moderate’, ‘low’ or ‘very low’ [34, 35]. Four aspects of GRADE were taken into account which are: ROB, inconsistency, imprecision, and indirectness [34].

Results

Study selection

A total of 1525 studies were identified through database and hand searching. After removing duplicates, 1283 studies were screened at the title and abstract stage. A total of 66 studies were retained for full text screening. Thirty-four studies met the eligibility criteria and were included. The detailed selection process and reasons for exclusion are highlighted in .

Study characteristics

From the 34 studies, 28 studies included asymptomatic individuals [36-63] and six investigated individuals with (LBP) [53, 54, 64–67]. One study investigated women with osteoporosis [68], and one investigated individuals with neck pain [56]. Fifteen PBOM were investigated, and to facilitate interpretation of results, they were grouped into five categories (see . Reliability was evaluated in all 34 studies, criterion validity in six studies and construct validity in seven studies: with no study evaluating responsiveness. Tables and summarise the characteristics of the included studies and the investigated measurement properties. SD = Standard deviation, F = Female, M = Male, HHD = Hand-held dynamometer, CLBP = Chronic low back pain, NP = Neck pain,? = Unknown. Abbreviations: ICC = Intraclass correlation coefficient, 95% CI = 95% confidence interval, SEM = Standard Error of Measurement, r = Pearson’s correlation, LoA = Limits of agreement, MIC = Minimal important change, MDD = Minimum detectable difference, SRD = Smallest real difference, CV = Coefficient of variation, SDC = Smallest detectable change. CLBP = Chronic low back pain, NP = Neck pain, Flex = Flexion, Ext = Extension, Rot = Rotation. DLLM = Double leg lowering manoeuvre, HHD = Hand-held dynamometer. MBTs = Medicine ball toss tests, h = hour, min = minute, N.m = Newton per meter, kg = kilogram, Nm/kg = Newton per kilogram, S = session, D = day.

Risk of bias in individual and across studies

illustrates the ROB for each population and outcome measures. Of those studies that measured reliability, six studies exhibited adequate ROB [40, 43, 54, 57, 62, 68], four had very good ROB for criterion validity [43, 57, 60, 63], and one rated as very good ROB for construct validity [47, 52]. The remaining studies were rated as either doubtful or with inadequate ROB [37, 39, 41, 42, 45, 47–53, 56, 58, 60, 61, 63, 65, 67]. Abbreviations: Ext = Extension, Flex = Flexion, Lat. Flex = lateral flexion, Rot = Rotation, R = Right, L. = Left, HHD = Hand-held dynamometer, BC = Back-Check, + = Sufficient, = Indeterminate, MIC = Minimal important change, 1 RM. = one repetition maximum, m = meter, TEX = Thoracic extension endurance test, EMG = electromyography, PTMI = Portable Trunk muscle torque Measurement Instrument, LBP = low back pain.

Synthesis of results

Results of the overall evidence of measurement properties against the COSMIN updated criteria and GRADE approach are presented in . In line with the COSMIN recommendation and the lack of information regarding the MIC for absolute reliability, the measurement error was not graded.

Hand-held dynamometer (HHD)

Asymptomatic individuals. Eight studies evaluated the intra-rater reliability of HHD for trunk flexion, extension and side bending where the dynamometer was externally fixed [43, 44, 47, 52, 60] or held by the examiner [58, 61, 63]. All studies rated as sufficient for the COSMIN criteria for good measurement properties where the ICC ranged from 0.8 to1.00 except for flexion from supine position where ICC = 0.67 [63] and side bending with the HHD positioned at axilla level where the ICC ranged 0.53 to 0.77 [61]. Overall, very low-quality evidence, due to very serious ROB, indicated very little confidence in the intra-rater reliability estimates for the use of HHD. The inter-rater reliability of HHD was measured in three studies [50, 61, 63], all with inadequate ROB and overall, very low-quality evidence indicates very little confidence in the inter-rater reliability estimate. Six studies investigated criterion validity of the HHD compared to ID [43, 52, 58, 60, 63] with moderate quality evidence overall indicating moderate confidence in the criterion validity estimates of the HHD in measuring trunk flexion and extension strength. Only one study with extremely serious ROB revealed sufficient convergent validity of the HHD compared to Back-Check (BC) [44] with overall, very low quality evidence. Individuals with spinal pain. One study measured intra-rater reliability of HHD in individuals with LBP [66], the study was rated as inadequate ROB, with a rating of sufficient reliability for flexion (ICC = 0.74) and insufficient for extension (ICC = 0.65). Overall, there was very low-quality evidence indicating very little confidence in the reliability of HHD in measuring trunk strength in individuals with LBP. One study measured the intra-rater reliability for the HHD in individuals with osteoporosis [68], with overall, very low quality evidence indicated very little confidence in the reliability estimates for the HHD within the osteoporotic population due to imprecision (sample < 50).

Digital loading cell

Asymptomatic individuals. Eight studies assessed the intra-rater reliability of digital loading cells [36, 40, 41, 48, 49, 51, 54, 62]. All reported sufficient intra-rater reliability for flexion, extension, and rotation against the COSMIN for good measurement properties where ICCs across all studies ranged from 0.75–1.00. Overall, high quality evidence indicates high confidence in the intra-rater reliability estimate for the loading cells in asymptomatic populations. Sufficient inter-rater reliability of the strain gauge dynamometer (ICC > 0.80) was reported in one study, with overall, very low quality evidence (extremely serious ROB and small sample size (n = <50) [51]. Three studies evaluated the measurement error using the LOA and SEM, two with inadequate ROB [49, 51] and one rated as adequate ROB [40]. As recommended by COSMIN, no overall grading was given due to lack of information regarding the MIC. Regarding the construct validity, values obtained from the loading cell were correlated with those from the barbell’s weight, indicating sufficient validity for trunk flexion strength [48]. However, there was very low-quality evidence due to extremely serious ROB and imprecision. There was sufficient convergent validity (r = 0.70) between the abdominal test and evaluation systems tool (ABTEST) and one-repetition maximum (1RM) in measuring abdominal strength with overall, very low-quality evidence indicating little confidence in validity estimates of the the digital loading cells [41]. Individuals with spinal pain. Sufficient intra-rater reliability of extension strength was observed in individuals with LBP with the ICC = 0.80. However, this study was graded as very low-quality evidence due to serious ROB and imprecision [54].

Specialised and commercialised equipment

Many devices are available to train and measure trunk muscle strength, and a significant correlation was observed between David Back system®, Tergumed® and Schnell® were r = 0.8 [70]. However, designs, stabilisation systems, and individual positioning varied from one device to another, leading to substantial inter-system comparisons [17]. Therefore, each PBOM was rated and graded separately in this review. Five machines were identified: David Back system® (David Health Solutions Ltd, Helsinki), MedXTM (Ocala, FL), Tergumed®, BackUpTM lumbar extension dynamometer (Priority One Equipment, Grand Junction, CO) and Back Check 607. Asymptomatic individuals. The intra-rater reliability of the David Back and BackUp devices were evaluated in three studies, all with inadequate ROB [39, 46, 59] and very low-quality evidence overall indicating very little confidence in their reliability estimates of trunk strength. A single study, with doubtful ROB, used the Back-Check device [56]; based on COSMIN criteria, good intra-rater reliability was reported (ICC>0.8) with overall very low quality evidence indicated by very serious ROB and imprecision. Sufficient inter-rater reliability of the Tergumed® dynamometer was indicated by ICCs ranging from 0.95–0.97 [55] with overall, very low-quality evidence. One study of inadequate quality evaluated the construct validity of the MedX dynamometer compared to a thoracic extension endurance test (TEX) in healthy individuals [64]. This study was rated indeterminate for the COSMIN criteria for good measurement as there was no hypothesis identified, and therefore this study was not graded. Individuals with spinal pain. Sufficient intra-rater and inter-rater reliability of the David Back system [65] and Tergumed dynamometer [67] respectively to assess trunk flexion, extension, and rotation strength among individuals with LBP. Overall, very low-quality evidence overall indicated very limited confidence in the reliability estimates of both devices. Sufficient inter-rater reliability of the Back-check, which was used to measure the flexion, extension and side bending strength from a standing position in 53 individuals with neck pain. However, there was very low-quality evidence (as only one study of doubtful quality and small sample available) [56]. One study of inadequate quality evaluated the construct validity of the MedX dynamometer compared to a thoracic extension endurance test in individuals with LBP [64]. This study was rated indeterminate for the COSMIN criteria for good measurement properties as there was no hypothesis identified, and therefore this study was not graded.

Functional tests (field tests)

Medicine ball toss tests were used to assess flexion, extension, and rotation strength in 20 individuals and showed good intra-rater reliability (ICC˃0.80) [57]. The overall level of evidence was very low as there was only one study of adequate quality and imprecision. The medicine ball toss tests were compared to the Biodex dynamometer where the Pearson correlation coefficient ranged from -0.04 to 0.1 (insufficient correlation) and with low quality evidence overall. The front abdominal power test (FAPT) and double leg lowering manoeuvre (DLLM) both showed excellent intra-rater reliability against COSMIN criteria. However, very low-quality evidence exists overall due to the study’s ROB and imprecision [38, 47]. Insufficient validity (negative correlation r = -0.338 to -0.446) between DLLM and HHD with overall low-quality evidence [47].

Novel devices

A triaxial isometric trunk muscle strength measurement system measured all trunk movements from an upright standing position [37]. Sufficient reliability were reported with overall very low-quality evidence was observed due to extremely serious ROB and imprecision [37]. The pressure air biofeedback (PAB®) is an isometric muscle testing instrument with an air-filled elastic ball held between the participant’s thighs. The PAB device demonstrated excellent to almost perfect reliability for extension strength (ICC = 0.99) in asymptomatic individuals (n = 24) and individuals with LBP (n = 18). However, very low-quality indicating very little confidence of the reliability estimates [53]. The Portable Trunk muscle torque Measurement Instrument (PTMI) was sufficiently correlated with the KinCom ID for flexion (r = 0.8) and extension (r = 0.7) however, the overall quality was rated very low indicating very little confidence in the results [69]. The last device identified is similar to a sphygmomanometer, where an inflatable cuff is placed around the abdomen and a mechanical manometer used to measure the deference in pressure (force) between baseline and participant maximum abdominal contraction [45]. Sufficient reliability, ICC = 0.95 and ICC = 0.99 for intra-rater and inter-rater reliability respectively, was observed with overall very low quality evidence due to extremely serious ROB and imprecision [45].

Discussion

This rigorous systematic review is the first to summarise practicable PBOM of trunk muscle strength and their measurement properties. Thirty-four studies and 15 PBOM were identified, categorised, and reported for their measurement properties.

Spinal pain population

Few studies, 8 out of 32, investigated reliability in spinal pain populations, and just two [48, 59] investigated validity. This raises concern regarding any reported evaluation of efficacy of rehabilitation programs in individuals with spinal pain [60]. Assessing trunk strength typically requires maximum effort of the individual during the testing [71]. Fear of pain, pain on exertion, lack of motivation and other confounding factors may affect the validity of the trunk strength testing in individuals with LBP. Pain is considered by some as a contraindication to maximum muscle strength testing [71] and may partly explain the paucity of research in spinal pain populations. Another possible reason is that in research settings, the ID is widely used to measure the trunk strength capacity in people with LBP [7, 72, 73]. As the current evidence highlighted the link between decreased trunk muscle strength and LBP [9, 74], review findings support the need for more high quality studies exploring the psychometric properties of practicable PBOM of trunk strength in spinal pain populations.

Performance‐based outcome measures PBOM

Digital loading cells can be considered a practicable and easy to use tool to evaluate flexion, extension, and trunk rotation strength in an asymptomatic population. However, in the absence of research in spinal pain population nor data on responsiveness, caution should be taken in drawing any conclusions with respect to their use in spinal pain populations. Additionally, very low quality evidence on the inter-rater reliability questions the confidence of findings where more than one examiner is involved. Moderate quality evidence supports criterion validity of the HHD, in relation to the ID, for measuring trunk flexion and extension muscle strength in an asymptomatic population. This aligns with other research examining HHD for proximal and distal muscle strength assessment in all extremities [27]. Findings suggest the use of the HHD as a practicable alternative to an isokinetic device in asymptomatic individuals. However, caution must be taken before interpreting the results due to the absence of high quality studies on the reliability of the HHD and the responsiveness of the tool among a spinal pain population. The applicability of the HHD in practice was previously questioned due to the variability of the results with repeated measurements and the influence of the examiner strength, especially when measuring large and strong muscle groups [26]. This finding was also highlighted in this review were the inter-rater reliability of the HHD was inconsistent. Using the HHD fixed by the examiner to measure flexion and extension strength in healthy individuals exhibited inconsistent inter-rater reliability, which could be attributed to examiner strength variability [75]. Given that the examiner strength can threaten the reliability of the HHD, several studies in this review used external fixation techniques, which facilitate participant force generation and could be usefully recommended when using the HHD to assess the trunk muscle strength, especially if the examination is carried out by different raters. The included field tests show promising levels of intra-rater reliability, using easy to administer measures that required little or no equipment to enhance the strength evaluation in clinical or sports settings [76]. However, caution must be taken as both criterion and construct validity of the included field tests is lacking. Consequently, more high-quality studies to explore the validity of the field tests are needed. Some novel devices reviewed in this paper, which showed sufficient psychometric properties, are quite complex and custom-built, and are therefore poorly reproducible or not feasible in clinical environments. Additionally, it may be time-consuming especially for untrained individuals.

Trunk movements

Most measures evaluated movements in the sagittal plane with fewer evaluating trunk side bending and rotation strength [36, 37, 39, 44, 46, 51, 55–57, 61, 62, 65, 67] (all with very low-quality evidence). This is in line with earlier research investigating trunk muscle strength [7, 77]. The abundance of research examining the trunk strength in the sagittal plane is unsurprising given the known correlation between the lumbar extensor musculature deconditioning and the development of LBP [8]. Trunk rotation however is essential for activities of daily activity and sporting tasks [78] but has been relatively under investigated [77]. Further inquiry may be useful given findings from epidemiological studies concluding that trunk rotation contributed to 11.4% of traumatic back injuries and 49% of non-traumatic back pain [79, 80].

Testing protocols

This review found a large variety in the use of PBOM rendering comparison between studies challenging. Where different testing positions were used, different levels of intra-tester reliability were observed. Trunk flexion strength, measured by a HHD, at 30˚ flexion showed excellent reliability ICC (2,1) = 0.9 compared to good reliability ICC (2,1) = 0.67 in a neutral position [63]. The 30˚ flexion position enhances the MVC output as previously suggested [81]. Notwithstanding position, the location of applied resistance also yielded different reliability estimates. Two studies [41, 48] investigated trunk flexion strength, using the digital loading cells from the same position (supine with flexed hips and knees) but differed with regard to the line of resistance, one being level with axilla ICC (2,1) = 0.99 and the other at the xiphoid process ICC(2,1) = 0.75. This was also noted when measuring the side bending strength using a HHD, from a sitting position; higher intra-rater reliability was observed when the resistance applied at the mid trunk ICC = 0.80–0.88 compared to the level of axilla ICC = 0.5–0.7 [61]. The influence of different testing protocols on reported psychometric properties was also seen for isokinetic testing [24, 73]. The variability in testing protocols utilised and the overall level of evidence prevents clinically important conclusions from being made [82].

Quality of the included studies

This review highlighted the number of methodological flaws in the included studies which therefore resulted in the rating of doubtful or inadequate risk of bias, with the overall quality for each measure being low or very low. For reliability studies, there was inappropriate description of the study design where there was a lack of explicit reporting of the stability of the participants and testing environment between sessions. Different protocols have been used in terms of the time interval between tests and re-test or between testers and this varied remarkably, from immediately consecutive measurements to >2 weeks. As previously recommended, the interval time between trials and between testing sessions should be long enough to avoid fatigue and short enough to not cause change in the construct being measured [34]. Therefore, studies were rated as inadequate on the ROB checklist, if the time was less than 2 minutes for the between trial interval and less than 15 min and more than 2 weeks for between sessions rest interval [33, 83, 84]. Reporting the expertise or training level of the examiners prior to the actual test was unclear, except in ten studies [39, 40, 46, 50, 60, 65, 66–69] and just nine studies considered and detailed testing order and randomisation [38, 40, 41, 57, 60, 61, 63, 66, 69]. To establish validity, it is necessary to include patients with spinal pain who are likely to undergo the same measurement in daily practice [85]. However, only eight studies included people with spinal pain [53, 54, 56, 64–68]. Sample size was another factor which contributed to downgrading due to imprecision (n< 50–100). Another methodological flaw, which is an important aspect of internal validity, is the blinding of the examiners for the results and/or status of the participants. Blinding was not well documented and only reported in five studies [39, 43, 55, 66, 67]. Statistical measures used to evaluate the psychometric properties are an important aspect of the ROB assessment. In keeping with COSMIN recommendations for reliability analysis, intraclass correlation coefficients, ideally ICC (2,1), for continuous data and Kappa coefficient statistics for dichotomous/nominal and ordinal data was the standard [33]. This was not always followed in the included studies, and subsequently the overall conclusion was downgraded, even if the outcome measures exhibit sufficient reliability.

Implications for clinical practice and research

The assessment of trunk strength enables coaches and clinicians to determine whether changes in muscle strength reflects a true gain or loss, or is a product of measurement error. Even though findings revealed high-quality evidence for intra-rater reliability of the digital loading cells and moderate-quality evidence for the HHD, the findings should be interpreted with caution given a paucity of evidence derived from people with spinal pain. Further high-quality studies using appropriate study designs and detailed testing protocols to standardise testing are needed to advance our understanding of practicable PBOM of trunk muscle strength, especially among a spinal pain population taking into account different levels of strength. The lack of studies measuring the responsiveness is a concern when considering the use of measures in spinal pain individuals undergoing rehabilitation and warrants immediate investigation. The review findings further highlighted the need to test the psychometric properties of measures evaluating trunk rotation and side bending strength; the majority of studies investigated sagittal plane motion.

Strengths and limitations

This review was conducted according to a registered and published protocol and followed the COSMIN methodology and recommendations. Bias was minimised, where two reviewers independently conducted all stages of this review. Despite this, some limitations that need to be acknowledged. The current review included studies that evaluated the trunk muscle strength in adults only >18 years old, which prevents the generalisability of the findings to younger populations. The rating approach to assess the methodological quality of the included studies was based on the lowest score principle, this may underestimate the overall quality of studies and subsequently downgrade the overall quality of evidence. This approach was strictly in line with the COSMIN recommendations to obtain a high standard for methodological design and reporting of psychometric properties studies.

Conclusion

The digital loading cells and the Hand-held dynamometer are objective and easy to use tools in everyday clinical practice. However, further studies are needed to investigate their psychometric properties in individuals with spinal pain to provide the practitioner with the most optimal tool to use with confidence. Review findings highlight gaps in the current evidence base of trunk strength measurement, notably a paucity of studies in pain populations and an absence of investigation of responsiveness; both of which are required to inform precision in clinical practice. Given the overall level of evidence, and the heterogeneity of methods and protocols used to measure trunk muscle strength, no recommendations regarding the optimal practicable outcome measure of trunk muscle strength can be made.

Preferred reporting items for systematic reviews and meta-analyses checklist-PRISMA.

(PDF) Click here for additional data file.

COSMIN definitions of measurement properties.

(PDF) Click here for additional data file.

MEDLINE full search string.

(PDF) Click here for additional data file.

Risk of bias assessment of both reviewers-reliability.

(XLSX) Click here for additional data file.

Risk of bias assessment of both reviewers-measurement error.

(XLSX) Click here for additional data file.

Risk of bias assessment of both reviewers-validity.

(XLSX) Click here for additional data file.

Criteria for good measurement properties and overall quality of evidence (GRADE) of both reviewers.

(XLSX) Click here for additional data file.
Table 1

Studies characteristics.

StudyCountry/SettingsSample sizeParticipants characteristicsOutcome measures
Andre et al (2012) [36]USAn = 23Age: M Mean (SD): 23 (±3.16), F 20.67 (± 12.39)asymptomatic Gender: F/M: 15/ 8Dynamometer (Fitrodyne; Fitronics, Bratislava, Slovakia)
Azghani et al (2009) [37]Iran / Laboratoryn = 30Age: Mean (SD): 25 (2.5)asymptomatic Gender: F/M: 0/30Triaxial isometric trunk strength measurement system
Conway et al (2016) [64]UK / LaboratoryAsymptomatic n = 38CLBP n = 19Age: Mean (SD)asymptomatic 31 (12)CLBP 28 (12)Gender: F/M: A 15 / 23, CLBP 9/ 10Thoracic extension endurance test TEX (the Biering–Sorensen test)
Cowley et al (2009) [38]USA / Laboratoryn = 8Age: Mean (SD)F 24.4 (4)/ M 23.3 (0.58)asymptomatic Gender: F/M: 5/3Front abdominal power test [FAPT])
De Blaiser et al (2018) [63]Belgiumn = 29Age: Mean (SD)F 21.6 (1.4), M 21.9 (1.1)asymptomatic Gender: F/M: 14/ 15Micro FET 2 HHD
Demoulin et al (2006) [39]Belgium / University hospitaln = 10Age: Mean (SD)F 22.8 (1.3)/ M 23.6 (2.2)asymptomatic Gender: F/M: 5/ 5David Back system
Essendrop, Schibye, and Hansen (2001) [40]Denmark / Laboratoryn = 19Age: Mean (SD): 35 (6.9)asymptomatic Gender: F/M: 13/ 6Strain gauge dynamometers fixed to the wall
Glenn et al. (2015) [41]USA/ LaboratoryReliabilityn = 30validity n = 23Age: Mean (SD)F 23 (1.9)/ M 22.9 (1.6)asymptomatic Gender: F/M: Reliability 19/ 11Validity 14/ 9The abdominal test and evaluation systems tool (ABTEST)
Graves et al (1990) [42]USA/ Laboratoryn = 136Age: Mean (SD), rangeF 24.3 (9.1), 17–52 / M 29.4 (10.7), 18–58asymptomatic Gender: F/M: 80/ 56MedX lumbar extension machine
Harding et al (2017) [43]Australian = 52Age: Mean (SD), range46.5 (20.5), 21–80asymptomatic Gender: F/M: 26/ 26HHD (Lafayette Manual Muscle Testing Systems; Lafayette, USA)
Jubany et al (2015) [44]Spain/ Laboratoryn = 20Age: Mean (SD): 27.6 (10.1)asymptomatic Gender: F/M: 11/ 9Custom-made instrument including HHD
Kahraman et al (2016) [66]Turkey/ Laboratoryn = 38Age: Mean (SD): 35 (10)CLBPGender: F/M: 14/ 24HHD
Kato et al (2020) [45]Japan/ Laboratoryn = 20Age: range: (24–41 years)asymptomatic Gender: F/M: 7/ 13Innovative exercise device
Kienbacher et al (2014) [46]Austrian = 86Age: rangegroup 1 (44): 18–49,group 2 (42): 50–90asymptomatic Gender: F/M: 40/ 46Davide Back system
Kienbacher et al (2016) [65]Austrian = 210Age (no): range (median)G1(67): 60–90 (68.3), G2 (81): 40–59 (49.8), G3 (62): 18–39 (27.5)LBPGender: F/M: 112/ 98Davide Back system
Ladeira et al (2005) [47]USAn = 28Age: range: 21–40asymptomatic Gender: F/M: 12/ 16Double leg lowering manuver (DLLM)/ Nicolas HHD.
Loss et al (2020) [48]Braziln = 15Age: Mean (SD): 27.7 (7.1)asymptomatic Gender: F/M: 15/ 0Portable, one-dimensional, trunk-flexor muscle strength measurement system (Measurement System)
Mesquita et al (2019) [49]Braziln = 21Age: Mean (SD): 64 (4)asymptomatic Gender: F/M: 21/0Digital loading cell fixed to the wall
Moreland et al (1997) [50]Canadan = 39Age: Mean (SD): 35 (9.3)asymptomatic Gender: F/M: 24/ 15Micro Fit HHD (make test)
Newman et al (2012) [61]Canada / research laboratoryn = 12Age: Mean (SD): 27.9 (9.9)asymptomatic Gender: F/M: 6/6MicroFET2 HHD
Paalanne et al (2009) [51]FinlandIntra-rater reliabilityn = 19Inter-rater reliabilityn = 15Age: Mean (SD), range22.7 (2.9), 19 30Asymptomatic Gender: F/M:/?Computerized strain gauge dynamometer
Park et al (2017) [52]Korean = 30Age: Mean (SD)F 33.1 (5.5)/ M 34.8 (7.5)asymptomatic Gender: F/M: 15/ 15HHD (Power TrackII Commander Muscle Tester) Fixed on specially designed chair
Pienaar and Barnard (2017) [53]South AfricaLBP n = 42Healthy n = 24LBP n = 18Age: Mean (SD): 47.58 (18.58)asymptomatic LBPGender: F/M: Healthy 12/ 12, LBP 9/ 9A pressure air biofeedback device (PABVR)
Pitcher, Behm, and MacKinnon (2008) [54]Canadan = 20Healthy n = 10LBP n = 10Age: Mean (SD): asymptomatic 24.7 (2.9)LBP 29.1 (8.2)Gender: F/M: 0/ 20Strain gauge dynamometer
Roussel et al (2006) [55]Belgium/ Ambulatory care in hospitaln = 61Age: Mean (SD): 36.9 (13.1)asymptomatic Gender: F/M: 30/31Tergumed equipment (4 devices for each movement)
Roussel et al (2008) [67]Belgium/ Ambulatory care in hospitaln = 12Age: Mean (SD): 40.2 (11.5)CLBPGender: F/M: 7/5Tergumed equipment (4 devices for each movement)
Sasaki et al (2018) [69]Japann = 24Age: Mean (SD): 21.1 (2.5)asymptomatic Gender: F/M: 8/ 16Portable trunk muscle torque measurement instrument (PTMI).
Scheuer and Friedrich (2010) [56]AustriaNP n = 53Healthy n = 42Age: Mean (SD): NP 49.7 (10.74)asymptomatic 48.7 (12.02)Gender: F/M: 73%/ 27%Back check
Sell et al (2015) [57]n = 20Age: Mean (SD): 22.7 (4.8)asymptomatic Gender: F/M: 10/ 10Portable trunk muscle torque measurement instrument (PTMI).
Steeves et al (2019) [62]Canada/ laboratoryReliabilityn = 10Validity n = 20Age: Mean (SD)Reliability 25 (3.8)Validity M 25.4 (5.0)/ F 23.9 (4.0)asymptomatic Gender: F/M: 14/ 16Novel trunk maximal isometric force assessment
Tarca et al (2020) [58]AustraliaReliabilityn = 31Validity n = 35Reliability:Age: Mean (SD)35.2 (18.0) years (52% males)Validity:Age: Mean (SD)33.9 (17.3) years, (57% males).A Lafayette HHD
Udermann, Mayer, and Murray (2004) [59]USAn = 60Age: Mean (SD)F 21 (2.2)/ M 22.6 (2.7)asymptomatic Gender: F/M: 30/ 30BackUP TM lumbar extension dynamometer
Valentin and Maribo (2014) [68]Denmarkn = 48Age: Mean (SD): 72 (9.3)OsteoporosisGender: F/M: 48/ 0HHD (Power Track II commander).
Yang et al (2020) [60]Chinan = 60Age: Mean (SD): 61.7 (7.6)asymptomatic Gender: F/M: 50/ 10HHD microFET3, tension (externally fixed)

SD = Standard deviation, F = Female, M = Male, HHD = Hand-held dynamometer, CLBP = Chronic low back pain, NP = Neck pain,? = Unknown.

Table 2

Summary of measurement properties.

StudyMeasurement propertyNo. of raters and testing scheduleGroupsPosition/ fixation/ resistanceMovement measured/ Muscle contractionStatistical measuresResults
Andre et al (2012) [36]Between days test re-test reliability.1 raterBetween daysTime interval:3–7 daysAsymptomaticSitting / no fixation/ resistance from the weight stack from the pulley system. RotIsotonic-ConcentricICC ICC 0.93–0.97 
Azghani et al (2009) [37]Test re-test reliability.1 raterWithin dayTime interval:2 min AsymptomaticStanding fixation from thoracic pad and pelvic pad. Flex, Ext, R & L lateral flexionR & L Rot/IsometricICC (2,1), SEMICC 0.69–0.91,SEM = 7.4–23.9
Conway et al (2016) [64]Construct validity: (Convergent) One raterWithin dayTime interval:10 Sec between contractions, 72 h between sessions. CLBPSitting, fixation around pelvic, thighs and feet. Resistance over the thoracic spine.Ext/Isometric Pearson’s correlationCombined groups:weak positive correlationr = 0.035,CLBPr = 0.120.A non-significant very weak negative correlation asymptomatic groupr = -0.060
Cowley et al (2009) [38]Test-re- test reliability.One rater Between daysTime interval:2 min between trials/ S 1 and S 2 were separated by 7 days, whereas S 2 and 3 were separated by 2 days.AsymptomaticSupine with knees 90˚ flex/ curl bar secured the feet to the ground/ resistance of 2-kg medicine ball. Flex.Isotonic—concentric.ICC (2,1)(95% CI) LOA using BlandAltman Plots. ICC = 0.95 (0.83–0.99),LoA = session 1 vs 2 = 15%LoA = session 2vs 3 = 17%
De Blaiser et al (2018) [63]Intra-rater, inter-rater reliability & criterion validity:Two ratersBetween daysTime interval:2 weeks between sessions/ 1 h between testers / 15 sec between trials. AsymptomaticSupine for (Flex), prone for (Ext)/ fixation around lateral malleolus and ASIS, PSIS. Resistance below the suprasternal notch for Flex & at the height of T4 for Ext.Flex (0˚ & 30˚), Ext (0˚ & 30˚)/ IsometricICC (2,1)(95% CI), SEM, LOA, Pearson’s correlation Intra-rater:Flex (0˚) ICC = 0.67 (0.4–0.83),SEM = 26.41Flex (30˚) ICC = 0.9 (0.8–0.95),SEM = 17.69Ext (0˚)ICC = 0.93 (0.92–0.98), SEM = 14.42Ext (30˚)ICC = 0.8 (0.16–0.93), SEM = 33.02Inter-rater:Flex (0˚) ICC = 0.78 (0.28–0.91),SEM = 17.98Flex (30˚) ICC = 0.93 (0.82–0.97),SEM = 16.45Ext (0˚)ICC = 0.76 (0.56–0.88),SEM = 20.88Ext (30˚) ICC = 0.82 (0.17–0.94), SEM = 31.53LOA = (-4.78 Nm- 18.61 Nm),r = 0.64–0.85).
Demoulin et al (2006) [39]Test-re- test, inter-rater, & inter site reliability. Two ratersBetween daysTime interval:7–10 days between sessions / 45 sec between trialsAsymptomaticSitting with fixation around pelvic, thighs and against tibial tuberosity, Additional shoulder pads were used for Flex and Rot testing. Resistance against the upper back. Flex, Ext, Rt & L lateral flexion, R & L Rot/Isometric. CV %Test re-test CV% = 3.4–7.6%,Inter-rater CV% = 3.4–8.1%,Inter site reproducibility CV% = 4.2–12.7%.
Essendrop, Schibye, and Hansen (2001) [40]Test-re- test reliability.One raterBetween daysTime interval:1week between sessions and 30 sec between trials.AsymptomaticStanding with fixation around pelvic. Resistance around the shoulders.Flex, Ext/ Isometric ICC(95% CI), Pearson correlation.Force measurements:FlexICC = 0.97 (−42.1 to −1.5),r = 0,97ExtICC = 0.93 (−76.4 to −19.5),r = 0.95Torque measurements:Flex ICC = 0.96 −6.6–8.9),r = 0,96Ext ICC = 0.91 −28.3 to −4.4),r = 0.94
Glenn et al. (2015) [41]Test re-test reliability & convergent validity.One raterWithin dayTime interval:5 min between trials.AsymptomaticSupine with the knees and hips at 90° Flex with no fixation. Resistance over the xiphoid process. Flex / IsometricICC(95% CI), Pearson’s correlationMax forceICC = 0.753 (0.544–0.875)Max powerICC = 0.893 (0.789–0.948).Correlation trial 1 and 2 r = 0.84Correlation between the 1 RM with average power r = 0.70. 
Graves et al (1990) [42]Test re-test reliability.One raterWithin day & between days.Time interval:72 hours between sessions and 20–30 min between trials.AsymptomaticSitting (0°, 12°, 24°, 36°, 48°, 60°, 72°) of Ext. Fixation around pelvic, thighs and against tibial tuberosity. Resistance against the upper back. Ext /IsometricPearson product-moment correlation, SEMWithin day (n = 136)D1 r = 0.78–0.96,D2 r = 0.94–0.98,D1 SEM = 37.6–46.9 Nm.D2 SEM = 28.7–34.4 N.m.Between days (n = 119)D1 & D2 r = 0.70–0.95,D2 & D3 r = 0.81–0.97.SEM (D1 & D2) = 40.2–54.1 NSEM (D2 & D3) = 32.8–46.3 N.
Harding et al (2017) [43]Test re-test reliability & criterion validity. One raterWithin day & between days.Time interval:30 s rest between trials / 7 days rest between sessionsAsymptomaticStanding with fixation 1 cm below ASIS. Resistance over the Seventh thoracic vertebrae. Ext /IsometricICC(95% CI), LOA, Pearson’s correlationTrial 2 vs trial 3:S1 ICC = 0.98 (0.97–0.99),S2 ICC = 0.96 (0.94–0.98).S1 vs S2:ICC = 0.901 (0.833–0.943).LOA = −6.63 to 7.70 kg, with a mean bias of +0.71 kg.r = 0.82–0.85.
Jubany et al (2015) [44]Test re-test reliability & construct validity (Convergent).One raterWithin day.Time interval:1 min between trials. AsymptomaticStanding, with fixation around pelvic and resistance over thoracic spine. Flex, Ext, side bending / Isometric ICC(95% CI), SEM, Pearson’s correlationICC = 1.0 (0.9–1),SEM = 0.3–0.8,r = 0.7–0.8
Kahraman et al (2016) [66]Test re-test reliability.One raterBetween days.Time interval:30 sec between trials and 48–72 hours between sessions. CLBPA 30˚ reclined position for Flex, and prone position for Ext. No fixation when measuring Flex and around hips and below knees when measure the Ext. Resistance for Flex, 1 inch below the sternal notch, for Ext, at the level of the inferior angle of the scapula.Flex, Ext/ Isometric/ICC (2,1)(95% CI) SEM, MDC, CVFlex:ICC = 0.74 (0.56–0.86),SEM = 1.88,MDC = 5.21, CV = 26.41Ext:ICC = 0.65 (0.42–0.80),SEM = 1.2.71,MDC = 7.51, CV = 27.62.
Kato et al (2020) [45]Intra-rater & inter-rater reliability.Time interval:Inter-rater: 1 hour between raters.Intra-rater one week.AsymptomaticSitting with back straight and feet supported and arms at the sides. No fixation.Resistance from the pressure of the device.Abdominal strengthICC, SEMIntra-rater:ICC = 0.95, 95% CI: 0.87–0.98,SEM = 2.0.Inter-rater:ICC = 0.99, 95% Cl: 0.96–0.99),SEM = 1.0
Kienbacher et al (2014) [46]Test re-test reliability.Between days.Time interval:1–2 days between S1 & S2, 6 weeks between S2 & S3/ 15 Sec between trials.AsymptomaticSitting upright to measure Flex, for Ext trunk flexed 30o anteriorly, for Rot upper body upright and lower body rotated to the opposite side by 30o. Fixation around back, pelvic, knees and feet, additional shoulder pads were used for Flex and Rot testing.Resistance over the upper back for Ext, over the shoulders for Flex and Rot.Flex, Ext, R & L. Rot/ IsometricICC (2,1), SEM/ SRD%Short term:Ext ICC = 0.83–0.85,Flex ICC = 0.87–0.94,Rot ICC = 0.81–0.89Long term:Ext ICC = 0.78–0.91,Flex ICC = 0.81–0.91Rot ICC = 0.80–0.87.Short term:Ext SRD%/ 22.27–28.92%Flex SRD% = 15.48–25.88%Rot. SRD% = 30.61–44.70%.Long term:Ext SRD% = 21.2–32.68%Flex SRD% = 18.49–27.00%Rot. SRD% = 33.29–44.99%.
Kienbacher et al (2016) [65]Test re-test reliability.Between days.Time interval:1–2 days between S1 & S2, 6 weeks between S2 & S3/ 15 Sec between trials.LBPSitting upright to measure Flex, for Ext trunk flexed 30o anteriorly, for Rot upper body upright and lower body rotated to the opposite side by 30o. Fixation around back, pelvic, knees and feet, additional shoulder pads were used for Flex and Rot testing.Resistance over the upper back for Ext, over the shoulders for Flex and Rot.Flex, Ext, R. & L. Rot/ IsometricICC (2,1), SEM, SRD%Short term:ICC = 0.86–0.96, SEM = 8.58–21.16,SRD% = 18.60–50.57%,Long term:ICC = 0.84–0.96,SEM = 9.53–24.43,SRD% = 20.84%- 51.92%.
Ladeira et al (2005) [47]Test re-test reliability & construct validity (Convergent).four ratersWithin dayTime interval:15 min between S1 and S2/ 30 sec between trials.AsymptomaticDLLM: Supine with hips flexed to 90o, knees and ankles in neutral position. HHD: supine with hips and knees at 90o. No fixation, no resistance for DLLM, at the sternum during HHD measurement. Flex / DLLM: Eccentric/ HHD: IsometricICC (1,1),(95% CI) Pearson’s correlationDLLMICC (1,1) = 0.955 (0.90–0.97),r = 0.93HHDr = 0.968,Correlation r = -0.33 and -0.44.
Loss et al (2020) [48]Test–retest reliability & construct validity. Within day & between days.Time interval:24 h between days test re-test/ 2 min between trials. AsymptomaticSupine with knees and hips flexed, with no fixation. Resistance at the level of axilla. Flex / Isometrict test (for construct validity).ICC (1, 2), SEM, MDC. p = 0.10–0.44ICC = 0.99,SEM = 0.1–1.6,MDC = 0.3–3.1N. 
Mesquita et al (2019) [49]Test re-test reliability.One raterBetween days.Time interval:15 sec rest between trials and 48 h rest between sessions. AsymptomaticUpright sitting with fixation around legs. Resistance for Ext over the scapula, for Flex at the level of xiphoid process. Flex, Ext/ Isometric. ICC (2,1) SEM, MDDICC = 0.86–0.93,SEM = 17.6–18.4,MDD = 48.9–51.1. 
Moreland et al (1997) [50]Inter rater reliability.Three ratersBetween days.Time interval:30 sec between trials and 3 sessions in 3 dyes. AsymptomaticFlex (Semi reclined position 30˚), Ext (prone with trunk out of the table). No fixation during Flex, for Ext (around hips and below knees).Resistance applied 1 inch below the sternal notch during Flex measurement, and at the level of the inferior angle of the scapula during Ext.Flex, Ext/ Isometric. ICC (2,1) SEMICC = 0.24–0.25,SEM = 60–68 N. 
Newman et al (2012) [61]Intra-rater & inter-rater reliabilityTwo raters Between days.Time interval:More than 24 h between sessions and 30 sec between trials. AsymptomaticSitting with fixation around pelvic. Resistance on the lateral aspect of the trunk, at the level of the axilla or mid trunk. Side bending (dominant)/ IsometricICC (2,1),(95% CI),SEMAxilla position:Intra-rater ICC = 0.5–0.7Inter-rater ICC = 0.7–0.8SEM = 0.22 Nm/kg.Mid trunk position:Intra-rater ICC = 0.80–0.86Inter-rater ICC = 0.87–0.88SEM = 0.09 Nm/kg.
Paalanne et al (2009) [51]Intra-rater & inter-rater reliability.Two raters Within & between days.Time interval:Intra-rater (7 days) between sessions, Inter-rater (30 min between sessions). AsymptomaticStanding with fixation against the popliteal fossa, lumbar spine, and on scapular level during Flex and Rot assessment. ForExt, the fixation against proximal part of tibia, pelvis, and sternum. Resistance during Flex & Rot was positioned against chest and over the spine of the scapula during Ext measurement.Flex, Ext, R & L Rot/ Isometric. ICC (1,1),ICC (3,1)95% LOA. Intra-rater:ICC (1,1) = 0.84–0.95,95% LOA = -8.37, 7.47- -18.81, 14.11,Inter-rater:ICC (3,1) = 0.84–0.88,95% LOA = -9.52,7.96- -29.40, 18.16.
Park et al (2017) [52]Test re-test reliability & criterion validity.Between daysTime interval:2 h between HHD testing and Isokinetic.AsymptomaticSitting with fixation around pelvic. Resistance at T7 spinous process.Ext/ IsometricICC,(95% CI) Pearson’s correlationICC = 0.82 (0.65–0.91)r = 0,65
Pienaar and Barnard (2017) [53]Test re-test reliability & construct validity (Convergent).One raterBetween daysTime interval:1 min rest between trialsAsymptomatic & LBP. Sitting with fixation around the thorax and resistance just below the inferior angles of the scapula. Ext/ IsometricICC, SEM, Pearson’s correlationICC = 0.99,SEM = 1.55, PAB (mb)Day 1 EMG (lV):both groups r = .75,Asymptomatic = .75,LBP = .26Day 2:r = Whole .63,Asymptomatic = .73,LBP = (-.11)
Pitcher, Behm, and MacKinnon (2008) [54]Test re-test reliability.One raterBetween daysTime interval:24–72 h between sessions / 2 min between trials. Asymptomatic & LBP.Prone with fixation around the lower legs, thighs, and mid-buttocks. Resistance at the level of T6- T7. Ext/ IsometricICCAsymptomaticICC = 0.98.LBP ICC = 0.80. 
Roussel et al (2006) [55] Inter-rater, intra-rater reliability.Two ratersWithin dayTime interval:15 min between sessions/ 10 sec between trialsAsymptomaticSitting with knees flexed 20° to 40° for Flex & Ext and 90° for Rot & lateral flexion. Fixation around pelvis, the trunk, and the legs. Flex, Ext, R & L lateral flexion, R & L Rot/ Isometric. ICC(2,1), (ANOVA)Inter-rater ICC (2,1) = 0.95–0.97,Intra-rater F = 0.03–5.04.
Roussel et al (2008) [67]Inter-rater reliability.Two ratersBetween daysTime interval:1–7 days between sessions. CLBPSitting with knees flexed 20° to 40° for Flex & Ext and 90° for Rot & lateral flexion. Fixation around pelvis, the trunk, and the legs. Flex, Ext, R & L lateral flexion, R & L Rot/ Isometric.ICC(2,1)SEMICC = 0.93–0.97SEM = 26.7–51.7. 
Sasaki et al (2018) [69]Criterion Validity. One trial on each device.AsymptomaticSitting with fixation around the pelvic and proximal to the knees. Resistance for Flex: against sternum, For Ext: against upper back. Flex & Ext.ICC (2,1)Flex ICC = 0.807,Ext ICC = 0.789 
Scheuer and Friedrich (2010) [56]Inter-rater and intra-rater reliability.Tow ratersWithin day & between daysTime interval:Session 1 and 2 on day 1 separated by 30–60 min, 3–5 days then another 2 sessions on day 2 separated by 30–60 min)Asymptomatic & NP individualsStanding with fixation around the pelvic and resistance at sternum level. Flex, Ext, R & L Side bending / Isometric. ICC, ANOVATest retest:NP ICC = 0.82–0.89Asymptomatic ICC = 0.80–0.88,Inter-rater:NP ICC = 0.00–0.36Asymptomatic ICC = 0.00,Short term intra-rater:NP ICC = 0.00–0.41Asymptomatic ICC = 0.00,Long term intra-rater:NP ICC = 1.12–1.49,Asymptomatic ICC = 1.73–7.21.
Sell et al (2015) [57]Test re-test reliability & criterion validity. Between daysTime interval:2 sessions separated by 24 h. AsymptomaticTall kneeling position with no fixation and resistance from the medicine ball. Flex, Ext, R & L Rot/ Concentric. ICC (2,1),(95% CI) SEM, Pearson’s correlationFlex ICC = 0.83 (0.60–0.93), SEM = 26.02Ext ICC = 0.83 (0.59–0.93),SEM = 30.16Right. Rot ICC = 0.87 (0.66–0.94), SEM = 24.5Left, Rot ICC = 0.90 (0.7–0.9), SEM = 17.44r = 0.047–0.180. 
Steeves et al (2019) [62]Test re-test reliability & Construct validity.Between daysTime interval:24 h between sessions (day 1 and day 2)/ 4 min between movements. AsymptomaticSitting with fixation around feet. Resistance inferior to axilla region during Flex, and over the shoulder during rotation movement.Flex, Rotational push (R and L), Rotational pull (R and L), Kayak-Stroke Simulation/ Isometric. ICC, Pearson’s correlationWithin day reliability:ICC = 0.91–0.99Between days reliability:ICC = 0.95–1.00r = -0.22- -0.82
Tarca et al (2020) [58]Test re-test reliability & Criterion validity. Between daysTime interval:7 days for reliability, 15 min for validity. Asymptomatic25° reclined supine position, 25°hip Flex with knee extended on the plinth. No fixation and resistance over the sternum just below the sternal notch.Abdominal Flex strengthICC (95% CI)SEM, LOA,Reliability:ICC = .86, CI = (.72-.93)SEM = 4.7 N.m.Validity:ICC = .82 (.57–.92). (P = .001).LOA = 37.5 to −19.7 N·m. 
Udermann, Mayer, and Murray (2004) [59]Test re-test reliability.Between daysTime interval:24 h between sessions and 30 sec between test angles. AsymptomaticSitting with fixation around the pelvic and thighs. Resistance over the spine of the scapula. Ext/ Isometric. ICC ICC = 0.92–0.97
Valentin and Maribo (2014) [68]Test re-test reliability.Between days,2 sessions/ 2 protocols (tester and tripod).Time interval:7 days between sessions/ 60 sec between trials / 5 min between protocols. OsteoporosisProne position with no fixation. Ext/ Isometric.ICC (1,2),95% CISEM,Tester fixated:ICC = 0.75 (0.63–0.88),SEM = 27.1.Tripod fixated:ICC = 0.90 (0.84–0.95),SEM = 20.5. 
Yang et al (2020) [60]Test re-test reliability & criterion validity. Between daysTime interval:A week interval between sessions / 1 min interval between trials and 1 h rest between each testing positions. AsymptomaticFrom three positions: sitting, standing and prone. Fixation around the pelvic (standing), around thighs (sitting), no fixation (prone). Resistance at the level of the xiphoid process (standing)/ over the superior borders of the scapula (sitting)/ At the level of scapula (prone). Ext/ Isometric.ICC(95% CI) SEM, LOA, CV, Pearson’s correlationSitting:ICC = 0.90 (0.83–0.94)SEM = 13.2,LOA = -37.83, 44.94, CV = 36.6.Standing:ICC = 0.92 (0.87–0.95), SEM = 25.5,LOA = -70.35, 90.15, CV = 20.3.Prone:ICC = 0.93 (0.88–0.95),SEM = 13.0,LOA = -35.01, 47.10.r = 0.32–0.54

Abbreviations: ICC = Intraclass correlation coefficient, 95% CI = 95% confidence interval, SEM = Standard Error of Measurement, r = Pearson’s correlation, LoA = Limits of agreement, MIC = Minimal important change, MDD = Minimum detectable difference, SRD = Smallest real difference, CV = Coefficient of variation, SDC = Smallest detectable change. CLBP = Chronic low back pain, NP = Neck pain, Flex = Flexion, Ext = Extension, Rot = Rotation. DLLM = Double leg lowering manoeuvre, HHD = Hand-held dynamometer. MBTs = Medicine ball toss tests, h = hour, min = minute, N.m = Newton per meter, kg = kilogram, Nm/kg = Newton per kilogram, S = session, D = day.

Table 3

Summary of risk of bias, criteria for good measurement properties and overall quality of evidence (GRADE).

Measurement propertyStudyRisk of bias (ROB)Characteristics of good measurement propertyOverall ratingGRADE (quality of evidence)
Hand-held dynamometer (HHD)- Asymptomatic individuals
Reliability (Intra-rater). Harding et al (2017) [43] (Ext)Adequate+ Sufficient (+) Very low-quality evidence.(-2 Very serious ROB, there are multiple studies of inadequate quality, -1 for inconsistency.)
Jubany et al (2015) [44] (Ext, Flex, Lat.flex)Inadequate+
Ladeira et al (2005) [47] (Flex)Inadequate+
Park et al (2017) [52] (Ext)Inadequate+
Yang et al (2020) [60] (Ext)Inadequate+
Tarca et al (2020) [58]Inadequate+
De Blaiser et al (2018) [63] (Ext & Flex (0˚, 30˚)Inadequate±Ext & Flex 30˚ (+)Flex 0 ˚ (-)
Newman et al (2012) [61] (Lat. Flex)Inadequate±At axilla (-)Mid trunk (+)
Reliability(Inter rater)Moreland et al (1997) [50] (Flex, Ext)Inadequate- (±) Inconsistent Very low-quality evidence(-2 Very serious ROB as there are multiple studies of inadequate quality available, inconsistency and imprecision sample size <50–100)
De Blaiser et al (2018) [63] (Flex, Ext)Inadequate+
Newman et al (2012) [61] (Lat.flex)Inadequate+
Measurement errorHarding et al (2017) [43] (Ext)AdequateMIC (?) Indeterminate (?) Not graded
Jubany et al (2015) [44] (Ext, Flex, Lat. Flex)InadequateMIC (?)
Moreland et al (1997) [50] (Flex, Ext)InadequateMIC (?)
Yang et al (2020) [60] (Ext)InadequateMIC (?)
Tarca et al (2020) [58]InadequateMIC (?)
De Blaiser et al (2018) [63] (Flex, Ext)InadequateMIC (?)
Newman et al (2012) [61] (Lat. Flex)InadequateMIC (?)
Construct validity (convergent validity)Jubany et al (2015) [44](HHD vs. BC)Inadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB, as there is only one study of inadequate quality available, -2 Imprecision sample size <50)
Criterion validityHarding et al (2017) [43]. (Ext)Very Good+ (+) Sufficient Moderate- quality evidence (-1due to serous inconsistency)
Park et al (2017) [52] (Ext)Inadequate-
Yang et al (2020) [60] (Ext)Very Good-
Tarca et al (2020) [58] (Flex)Inadequate+
De Blaiser et al (2018) [63] (Ext & Flex)Very GoodFlex 0˚, 30˚ (+)Ext 0˚ (-), 30˚ (+)
Hand-held dynamometer (HHD)- Spinal musculoskeletal pain
LBPReliability(Intra-rater).Kienbacher et al (2016) [65](Ext)(Flex)Inadequate-+ (±) Inconsistent Very low-quality evidence(-3 Extremely serious ROB, as there is only one study of inadequate quality available, -1 for inconsistency and -2 for imprecision sample size <50)
Measurement errorKienbacher et al (2016) [65]InadequateMIC (?) Indeterminate (?) Not graded
Osteoporosis(ReliabilityIntra-rater).Valentin and Maribo (2014) [68] (Ext)Adequate+ Sufficient (+) Very low-quality evidence. (-1 Serious ROB) there is only one study of adequate quality and -2 for imprecision sample size <50
Measurement errorValentin and Maribo (2014) [68] (Ext)AdequateMIC (?) Indeterminate (?) Not graded
Digital loading cells- Asymptomatic individuals
(ReliabilityIntra-rater).Andre et al (2012) [36] (Rot.)Inadequate+
Essendrop, Schibye, and Hansen (2001) [40] (Ext, Flex)Inadequate+ Sufficient (+) High quality evidence(There are multiple studies of at least adequate quality)
Glenn et al. (2015) [41] (Flex)Inadequate+
Loss et al (2020) [48] (Flex)Adequate+
Mesquita et al (2019) [49] (Ext, Flex)Inadequate+
Paalanne et al (2009) [51] (Ext, Flex, R & L, Rot)Inadequate+
Pitcher, Behm, and MacKinnon (2008) [54] (Ext)Adequate+
Steeves et al (2019) [62] (Flex, Rotational push, Rotational pull, Kayak-Stroke Simulation)Adequate+
Reliability(Inter rater)Paalanne et al (2009) [51] (Ext, Flex, R & L Rot)Inadequate+ Sufficient (+) Very low-quality evidence (-3 Extremely serious ROB, as there is only one study of inadequate quality available, -2 for imprecision sample size <50)
Measurement errorEssendrop, Schibye, and Hansen (2001) [40] (Ext, Flex)AdequateMIC (?) Indeterminate (?) Not graded
Mesquita et al (2019) [49] (Ext, Flex)InadequateMIC (?)
Paalanne et al (2009) [51] (Ext, Flex, R & L Rot)InadequateMIC (?)
Construct validity (convergent validity)Glenn et al. (2015) [41] (Flex)Vs. 1 RM.Doubtful+ Sufficient (+) Very low-quality evidence (-2 Very serious ROB, there is only one study of doubtful quality available, and -2 for imprecision sample size <50)
Loss et al (2020) [48] (Flex)Vs. calibrated barbellsInadequate+ Sufficient (+) Very low-quality evidence (-3 extremely serious ROB, there is one study of inadequate quality, and -2 for imprecision sample size <50)
Steeves et al (2019) [62]Vs. 200-m race timeInadequate? Indeterminate (?) Not graded
Digital loading cells- Spinal musculoskeletal pain
LBP(Reliability(Intra rater).Pitcher, Behm, and MacKinnon (2008) [54] (Ext)Adequate+ Sufficient (+) Very low-quality evidence(-1 serious ROB as there is only one study of adequate quality, and -2 imprecision sample size <50)
Specialized and commercialized equipment- Asymptomatic individuals
(Reliability(Intra-rater).Demoulin et al (2006) [39] (Ext, Flex, Lat. Flex & Rot)(David- back)InadequateICC (?) Sufficient (+) Very low-quality evidence(-2 very serious ROB as there are multiple studies of inadequate quality, and -1 imprecision sample size <50–100)
Kienbacher et al (2014) [46] (Ext, Flex, & Rot)(David- back)Inadequate+
Graves et al (1990) [42](MedX)InadequateICC (?) Indeterminate (?) Not graded
Roussel et al (2006) [55] (Tergumed)InadequateICC (?) Indeterminate (?) Not graded
Udermann, Mayer, and Murray (2004) [59] (Ext)(BackUp)Inadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB as there is only one study of inadequate quality available and -1 for imprecision sample size <50–100)
Scheuer and Friedrich (2010) [56] (Back- check)Doubtful+ Sufficient (+) Very low-quality evidence(-2 Very serious ROB, as there is only one study of doubtful quality available, and -2 imprecision sample size <50).
(ReliabilityInter- rater).Roussel et al (2006) [55] (Tergumed)Inadequate+ Sufficient (+) Very low-quality evidence(Extremely serious ROB as there is only one study of inadequate quality available and imprecision sample size <50–100)
Scheuer and Friedrich (2010) [56](Back- check)Inadequate? Indeterminate (?) Not graded
Demoulin et al (2006) [39](David- back)Inadequate? Indeterminate (?) Not graded
Measurement errorGraves et al (1990) [42](MedX)Inadequate(MIC?) Indeterminate (?) Not graded
Kienbacher et al (2014) [46] (David- back)Inadequate(MIC?) Indeterminate (?) Not graded
Construct validity (convergent validity)Conway et al (2016) [64]Medx Vs. TEX.Inadequate? Indeterminate (?) Not graded
Specialized and commercialized equipment- Spinal musculoskeletal pain
CLBP(Reliability(Intra rater).Kienbacher et al (2016) [65](David- back)Inadequate+ Sufficient (+) Very low-quality evidence.(-3 Extremely serious ROB as there is only one study of inadequate quality available)
(ReliabilityInter- rater).Roussel et al (2008) [67] (Tergumed)Inadequate+ Sufficient (+) Very low-quality evidence.(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Measurement errorKienbacher et al (2016) [65](David- back)Inadequate(MIC?) Indeterminate (?) Not graded
Roussel et al (2008) [67] (Tergumed)Inadequate(MIC?) Indeterminate (?) Not graded
Construct validity (convergent validity)Conway et al (2016) [64]MedX Vs. TEX.Inadequate- Indeterminate (?) Not graded
NP(Reliability(Intra rater).Scheuer and Friedrich (2010) [56](Back- check)Doubtful+ Sufficient (+) Very low-quality evidence.(-2 Very serious ROB, as there is only one study of doubtful quality available, and -1 for imprecision sample size <50–100).
(Reliability(Inter- rater).Scheuer and Friedrich (2010) [56](Back- check)InadequateICC? Indeterminate (?) Not graded
Field tests- Asymptomatic individuals
(Reliabilityintra rater)Sell et al (2015) [57]Medicine ball toss tests (MBTs).Adequate+ Sufficient (+) Very low-quality evidence.(-1 Serious ROB as there is only one study of adequate quality and -2 for imprecision sample size <50).
Cowley et al (2009) [38]Front abdominal power test [FAPT])Doubtful+ Sufficient (+) Very low-quality evidence.(-2 Very serious ROB as here is only one study of doubtful quality available and -2 for imprecision sample size <50).
Ladeira et al (2005) [47]Double leg lowering manuver (DLLM)Inadequate+ Sufficient (+) Very low-quality evidence.(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
MeasurementErrorCowley et al (2009) [38]DoubtfulMIC? Indeterminate (?) Not graded
Sell et al (2015) [57]AdequateMIC? Indeterminate (?) Not graded
Construct validity (convergent validity)Ladeira et al (2005) [47]Double leg lowering manuver (DLLM) Vs. HHDVery Good- Insufficient (-) Low quality evidence.(-2 for Imprecision sample size <50).
Criterion validitySell et al (2015) [57]Medicine ball toss tests (MBTs)Vs. (The Biodex System 3)Very Good- Insufficient (-) Low quality evidence.(-2 Imprecision sample size <50).
Specially developed tools- Asymptomatic individuals
Reliability (intra-rater)Azghani et al (2009) [37]Triaxial isometric trunk strength measurement systemInadequate+ Sufficient (+) Very low-quality evidence.(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Pienaar and Barnard (2017) [53] (Ext)A pressure air biofeedbackInadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Kato et al (2020) [45]Innovative exercise deviceInadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Reliability (inter-rater)Kato et al (2020) [45]Inadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Measurement errorAzghani et al (2009) [37]Inadequate? Indeterminate (?) Not graded
Pienaar and Barnard (2017) [53] (Ext)Inadequate? Indeterminate (?) Not graded
Kato et al (2020) [45]Inadequate? Indeterminate (?) Not graded
Construct validity (convergent validity)Pienaar and Barnard (2017) [53] (Ext)A pressure air biofeedback Vs. EMGDoubtful+ Indeterminate (?) Not graded
Construct validity (discriminative validity)Pienaar and Barnard (2017) [53] (Ext)Inadequate+ Indeterminate (?) Not graded
Criterion validitySasaki et al (2018) [69] (Flex, Ext)(PTMI). Vs. Kin Com Isokinetic dynamometer).Inadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Specially developed tools- Spinal musculoskeletal pain (LBP)
Reliability (intra-rater)Pienaar and Barnard (2017) [53] (Ext)Inadequate+ Sufficient (+) Very low-quality evidence(-3 Extremely serious ROB as there is only one study of inadequate quality available and -2 for imprecision sample size <50).
Measurement errorPienaar and Barnard (2017) [53] (Ext)InadequateMIC? Indeterminate (?) Not graded
Construct validityPienaar and Barnard (2017) [53] (Ext)Doubtful- Indeterminate (?) Not graded

Abbreviations: Ext = Extension, Flex = Flexion, Lat. Flex = lateral flexion, Rot = Rotation, R = Right, L. = Left, HHD = Hand-held dynamometer, BC = Back-Check, + = Sufficient, = Indeterminate, MIC = Minimal important change, 1 RM. = one repetition maximum, m = meter, TEX = Thoracic extension endurance test, EMG = electromyography, PTMI = Portable Trunk muscle torque Measurement Instrument, LBP = low back pain.

  68 in total

1.  Spectral parameters of trunk muscles during fatiguing isometric axial rotation in neutral posture.

Authors:  S Kumar; Y Narayan
Journal:  J Electromyogr Kinesiol       Date:  1998-08       Impact factor: 2.368

Review 2.  Isokinetic testing in patients with neuromuscular diseases: a focused review.

Authors:  Lhassan El Mhandi; François Bethoux
Journal:  Am J Phys Med Rehabil       Date:  2013-02       Impact factor: 2.159

3.  Reliability of measurement of maximal isometric lateral trunk-flexion strength in athletes using handheld dynamometry.

Authors:  Bram L Newman; Courtney L Pollock; Michael A Hunt
Journal:  J Sport Rehabil       Date:  2012-08-16       Impact factor: 1.931

Review 4.  Measurements and evaluations in low back pain patients.

Authors:  P Malliou; A Gioftsidou; A Beneka; G Godolias
Journal:  Scand J Med Sci Sports       Date:  2006-08       Impact factor: 4.221

Review 5.  Reflecting on the global burden of musculoskeletal conditions: lessons learnt from the global burden of disease 2010 study and the next steps forward.

Authors:  Damian G Hoy; Emma Smith; Marita Cross; Lidia Sanchez-Riera; Fiona M Blyth; Rachelle Buchbinder; Anthony D Woolf; Tim Driscoll; Peter Brooks; Lyn M March
Journal:  Ann Rheum Dis       Date:  2014-06-09       Impact factor: 19.103

6.  Evaluation of isokinetic trunk muscle strength in adolescents with normal and abnormal postures.

Authors:  Katarzyna Barczyk-Pawelec; Jerzy Rafał Piechura; Wioletta Dziubek; Krystyna Rożek
Journal:  J Manipulative Physiol Ther       Date:  2015-08-05       Impact factor: 1.437

7.  Effect of fatigue on torque output and electromyographic measures of trunk muscles during isometric axial rotation.

Authors:  Joseph K-F Ng; Mohamad Parnianpour; Carolyn A Richardson; Vaughan Kippers
Journal:  Arch Phys Med Rehabil       Date:  2003-03       Impact factor: 3.966

8.  Changes in the activities of the trunk muscles in different kinds of bridging exercises.

Authors:  Yong Soo Kong; Yong Ho Cho; Ji Won Park
Journal:  J Phys Ther Sci       Date:  2014-01-08

9.  Age-related reduction of trunk muscle torque and prevalence of trunk sarcopenia in community-dwelling elderly: Validity of a portable trunk muscle torque measurement instrument and its application to a large sample cohort study.

Authors:  Eiji Sasaki; Shizuka Sasaki; Daisuke Chiba; Yuji Yamamoto; Atsushi Nawata; Eiichi Tsuda; Shigeyuki Nakaji; Yasuyuki Ishibashi
Journal:  PLoS One       Date:  2018-02-22       Impact factor: 3.240

Review 10.  Isokinetic Trunk Strength in Acute Low Back Pain Patients Compared to Healthy Subjects: A Systematic Review.

Authors:  Waleska Reyes-Ferrada; Luis Chirosa-Rios; Angela Rodriguez-Perea; Daniel Jerez-Mayorga; Ignacio Chirosa-Rios
Journal:  Int J Environ Res Public Health       Date:  2021-03-04       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.