Literature DB >> 30366246

Reliability and validity of trunk flexor and trunk extensor strength measurements using handheld dynamometry in a healthy athletic population.

Cedric De Blaiser1, Roel De Ridder2, Tine Willems2, Lieven Danneels2, Philip Roosen2.   

Abstract

OBJECTIVES: To investigate reliability and validity of handheld dynamometry (HHD) strength tests to accurately measure isometric trunk flexion and extension strength.
DESIGN: Test-retest design and comparative analysis to investigate reliability and validity respectively.
SETTING: Isometric trunk flexion and extension strength, measured with a handheld dynamometer, was compared to isometric strength testing on a stationary isokinetic dynamometer. Different test positions were examined for the HHD measurements for trunk flexion and extension strength. MAIN OUTCOME MEASURES: Trunk muscle strength was calculated in newton metres (Nm) for both devices. Results of both devices were compared with Pearson correlations and agreement between both methods was explored with Bland-Altman plots. ICC values were calculated to assess HHD intra- and inter-tester reliability.
RESULTS: Reliability was good to excellent for all HHD tests (ICC = 0.67-0.93). High correlations were found between the HHD tests and stationary dynamometer tests (r = 0.65-0.86). Bland-Altman plots showed agreement between both methods for the trunk flexion test, supported in 30° trunk flexion and for the trunk extension test in a prone position in 0° trunk flexion.
CONCLUSION: Handheld dynamometry is reliable and a clinically applicable valid method to evaluate isometric trunk flexion and extension strength.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Abdominal muscles; Back muscles; Core strength; Isometric contraction

Mesh:

Year:  2018        PMID: 30366246     DOI: 10.1016/j.ptsp.2018.10.005

Source DB:  PubMed          Journal:  Phys Ther Sport        ISSN: 1466-853X            Impact factor:   2.365


  6 in total

1.  Practicable performance-based outcome measures of trunk muscle strength and their measurement properties: A systematic review and narrative synthesis.

Authors:  Shouq Althobaiti; Alison Rushton; Ahmad Aldahas; Deborah Falla; Nicola R Heneghan
Journal:  PLoS One       Date:  2022-06-17       Impact factor: 3.752

2.  Core muscle strength can be reliably measured using a novel isokinetic device: An intra-observer study.

Authors:  Marit L Mulder; Elke Van den Steen; Jan De Neve; Adam Weir
Journal:  J Back Musculoskelet Rehabil       Date:  2022       Impact factor: 1.456

3.  Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer.

Authors:  Angela Rodriguez-Perea; Luis J Chirosa Ríos; Dario Martinez-Garcia; David Ulloa-Díaz; Francisco Guede Rojas; Daniel Jerez-Mayorga; Ignacio J Chirosa Rios
Journal:  PeerJ       Date:  2019-10-18       Impact factor: 2.984

4.  Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population.

Authors:  Fahad Tanveer; Syed Asadullah Arslan; Haider Darain; Ashfaq Ahmad
Journal:  Pak J Med Sci       Date:  2021 Mar-Apr       Impact factor: 1.088

5.  Comparison of Isometric Strength of the Trunk and Hip Muscle Groups in Female Athletes with and without Low Back Pain: A Cross-Sectional Study.

Authors:  Niloufar Kazemkhani; Shabnam ShahAli; Sanaz Shanbehzadeh
Journal:  Med J Islam Repub Iran       Date:  2022-06-13

6.  ISOKINETIC TRUNK STRENGTH, VALIDITY, RELIABILITY, NORMATIVE DATA AND RELATION TO PHYSICAL PERFORMANCE AND LOW BACK PAIN: A REVIEW OF THE LITERATURE.

Authors:  Zouita Ben Moussa A; Zouita S; Ben Salah Fz; Behm Dg; Chaouachi A
Journal:  Int J Sports Phys Ther       Date:  2020-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.