| Literature DB >> 35692590 |
Carlos M Ardila1, Andrés Elorza-Durán1, Daniel Arrubla-Escobar1,2.
Abstract
Objectives: To evaluate the efficacy of computer-aided design/computer-aided manufacturing (CAD/CAM) technology in interventions implemented in orthodontics.Entities:
Mesh:
Substances:
Year: 2022 PMID: 35692590 PMCID: PMC9184227 DOI: 10.1155/2022/5310555
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.246
Figure 1Flowchart of the CTs selection method.
Features of the CTs evaluated.
| Authors | Participants | Mean | Female | Intervention | Main | Treatment time |
|---|---|---|---|---|---|---|
| Shim et al. 2022 | 46 | 16 years | 28/18 | CAD/CAM group with multistranded stainless steel wires versus lab group with multistranded stainless steel wires versus a group with stainless steel Ortho-FlexTech wires (traditional group) | The CAD/CAM group experienced a less intercanine width decrease ( | 6 months of bonding fixed retainers |
| Adanur-Atmaca et al. 2021 | 132 | 16 years | 92/40 | Lingual retainers with 0.016 3 0.022 in dead soft wire versus Lingual retainers with 0.0215 in 5 strand stainless steel wire versus lingual retainers with 0.014 3 0.014-in CAD/CAM nitinol versus lingual retainers with connected bonding pads | Gingival inflammation and calculus accumulation were the lowest in CAD/CAM group ( | 12 months |
| Hegele et al. 2021 | 38 | 14 years | 23/15 | Indirect bonded customized CAD/CAM brackets versus direct bonded self-ligating brackets | No differences between both treatment groups were found concerning overall treatment time, the number of appointments, and the number of archwire bends. Bonding failures occurred more often using the CAD/CAM system. Indirectly bonded brackets did not have to be repositioned as often as directly bonded brackets. Treatment results with both systems were similar concerning their effects on the reduction of ABO score. The number of the used archwires was higher in the CAD/CAM group | 16.7 months |
| Jackers et al. 2021 | 24 | 23 years | 17/7 | CAD/CAM custom indirect bonding self-ligating system versus indirect bonding self-ligating standard system | The indirect bonding self-ligating standard system had a 26% longer overall orthodontic treatment time compared with the CAD/CAM customized bracket system ( | 393 days in the CAD/CAM group |
| Alrawas et al. 2021 | 60 | 20 years | 43/17 | CAD/CAM NiTi retainer, multistranded stainless steel versus single-stranded nickel-free titanium retainer versus vacuum-formed removable group | All groups showed some relapse in the lower anterior teeth. No statistical significance was found intergroup in terms of all measured values. Less plaque accumulation and gingival inflammation were observed in the CAD/CAM NiTi retainer group but without statistical significance | 6 months of follow-up |
| Czolgosz et al. 2020 | 27 | 17 years | 15/12 | Computer-aided indirect bonding method versus traditional direct bonding of orthodontic brackets | Clinical chair time for bonding half a mouth was significantly shorter for computer-aided indirect bonding ( | Not reported |
| Gelin et al. 2020 | 41 | 17 years | 43/18 | To compare CAD/CAM customized nitinol retainers with standard stainless-steel fixed retainers | No significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival were observed. Both retainers eventually appeared to be equally effective in maintaining periodontal health | 12 months |
| Penning et al. 2017 | 174 | 14 years | 103/71 | Customized orthodontic system versus non-customized orthodontic system | The customized group had more loose brackets, a longer planning time, and more complaints ( | 1.29 years in the customized system |
Quality of the selected studies (Jadad et al. 1996).
| Clinical trial | Randomization | Double blinding | Withdraw | Proper randomization | Proper double blinding | Score |
|---|---|---|---|---|---|---|
| Shim et al. (2022) | 1 | 0 | 1 | 1 | 0 | 3 |
| Adanur-Atmaca et al. (2021) | 1 | 0 | 1 | 1 | 0 | 3 |
| Hegele et al. (2021) | 0 | 0 | 0 | 0 | 0 | 0 |
| Jackers et al. (2021) | 1 | 0 | 1 | 0 | 0 | 2 |
| Alrawas et al. (2021) | 1 | 0 | 1 | 1 | 0 | 3 |
| Czolgosz et al. (2020) | 1 | 0 | 1 | 1 | 0 | 3 |
| Gelin et al. (2020) | 1 | 0 | 1 | 1 | 0 | 3 |
| Penning et al. (2017) | 1 | 0 | 1 | 1 | 0 | 3 |