| Literature DB >> 29850512 |
Maria Francesca Sfondrini1, Paola Gandini1, Maurizio Malfatto1, Francesco Di Corato1, Federico Trovati1, Andrea Scribante1.
Abstract
INTRODUCTION: Intraoral scanners allow direct images of oral situation, with fewer steps than conventional impressions. The purpose of this study was to compare the accuracy of digital impressions, traditional impressions, and digitalization of full-arch gypsum models, to evaluate timing of different methods and finally to study perception of patients about conventional and digital impression techniques.Entities:
Mesh:
Substances:
Year: 2018 PMID: 29850512 PMCID: PMC5937598 DOI: 10.1155/2018/4103232
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1Measurement points for upper arch.
Figure 2Measurement points for lower arch.
Figure 3Flow chart with diagrammatic representation of the test groupings for the three variables.
Figure 4Accuracy of measurements (mm) among gypsum, digitalized gypsum, and full digital models.
Descriptive statistics of accuracy (mm) of three different measurements (conventional measurement, digital measurement, and digitalization of gypsum model).
| Measurements | Group | Model | Mean | SD | Min | Median | Max | Significance |
|---|---|---|---|---|---|---|---|---|
| Upper arch | (1A) | Gypsum | 30.35 | 2.28 | 24.8 | 31 | 32.5 | |
| (1B) | Digitalized gypsum | 28.9 | 2.72 | 21.72 | 29.43 | 32.25 | ns | |
| (2) | Digital | 29.46 | 2.66 | 22.66 | 29.9 | 33.18 | ||
|
| ||||||||
| Lower arch | (1A) | Gypsum | 28.06 | 1.63 | 24.5 | 28.65 | 30 | |
| (1B) | Digital gypsum | 28.07 | 1.39 | 25.09 | 28.15 | 30.33 | ns | |
| (2) | Digital | 28 | 1.30 | 25.23 | 28.2 | 29.99 | ||
|
| ||||||||
| Intercanine upper | (1A) | Gypsum | 34.03 | 1.83 | 31.4 | 33.7 | 37.6 | |
| (1B) | Digital gypsum | 34 | 1.84 | 30.77 | 33.54 | 37.46 | ns | |
| (2) | Digital | 33.8 | 1.93 | 31.15 | 33.54 | 36.76 | ||
|
| ||||||||
| Intercanine lower | (1A) | Gypsum | 25.87 | 2.15 | 22 | 25.63 | 31 | |
| (1B) | Digital gypsum | 25.96 | 1.99 | 21.54 | 25.61 | 29.95 | ns | |
| (2) | Digital | 25.64 | 2.01 | 21.98 | 25.51 | 30.05 | ||
|
| ||||||||
| Intermolar upper | (1A) | Gypsum | 40.78 | 2.12 | 36.9 | 40.85 | 45.5 | |
| (1B) | Digital gypsum | 40.53 | 2.40 | 36.98 | 40.1 | 46.25 | ns | |
| (2) | Digital | 40.36 | 2.24 | 37.37 | 40.04 | 46.11 | ||
|
| ||||||||
| Intermolar lower | (1A) | Gypsum | 39.05 | 3.48 | 31 | 39.55 | 45.2 | |
| (1B) | Digital gypsum | 38.93 | 3.36 | 31.66 | 39.88 | 45.65 | ns | |
| (1B) | Digital gypsum | 38.93 | 3.36 | 31.66 | 39.88 | 45.65 | ||
Descriptive statistics of timing (minutes : seconds) related to conventional and digital impression methods.
| Times | Group | Impression method | Mean | St Dev | Min | Median | Max | Significance |
|---|---|---|---|---|---|---|---|---|
| Total time | (1) | Conventional | 22:06 | 00:15 | 21:45 | 22:03 | 22:35 |
|
| (2) | Digital | 05:49 | 00:20 | 05:15 | 05:54 | 06:14 | ||
| Chairside time | (1) | Conventional | 07:32 | 00:10 | 07:10 | 07:32 | 07:50 |
|
| (2) | Digital | 05:49 | 00:20 | 05:15 | 05:54 | 06:14 | ||
| Processing time | (1) | Conventional | 14:34 | 00:14 | 14:15 | 14:29 | 15:02 |
|
| (2) | Digital | 00:14 | 00:01 | 00:13 | 00:15 | 00:17 |
Figure 5Time measurements (minutes) of conventional and digital techniques.
Figure 6Questionnaire results for conventional and digital techniques (VAS scores: 0: maximum discomfort; 10: maximum comfort).
Questionnaire results. VAS scale ranged from 0 (maximum discomfort) to 10 (no discomfort at all).
| Question | Group | Technique | Mean | SD | Min | Median | Max | Significance |
|---|---|---|---|---|---|---|---|---|
| What was the overall sensation about the impression technique? | (1) | Conventional | 4.29 | 3.10 | 0.00 | 3.50 | 9.00 |
|
| (2) | Digital | 9.00 | 0.88 | 7.00 | 9.00 | 10.00 | ||
| Did you find the procedure comfortable? | (1) | Conventional | 2.57 | 3.11 | 0.00 | 1.50 | 9.00 |
|
| (2) | Digital | 9.14 | 0.86 | 7.00 | 9.00 | 10.00 | ||
| How do you consider the time to complete the procedure? | (1) | Conventional | 3.57 | 3.06 | 0.00 | 2.50 | 9.00 |
|
| (2) | Digital | 6.07 | 2.76 | 1.00 | 6.50 | 10.00 | ||
| How do you consider the dimension of instruments used? | (1) | Conventional | 2.57 | 3.41 | 0.00 | 0.50 | 9.00 |
|
| (2) | Digital | 6.07 | 2.70 | 2.00 | 6.50 | 10.00 | ||
| When evaluating gag reflex was the procedure comfortable? | (1) | Conventional | 0.64 | 0.84 | 0.00 | 0.00 | 2.00 |
|
| (2) | Digital | 9.71 | 0.47 | 9.00 | 10.00 | 10.00 |