Literature DB >> 28364905

Memotain: A CAD/CAM nickel-titanium lingual retainer.

Neal D Kravitz1, Dan Grauer2, Pascal Schumacher3, Yong-Min Jo4.   

Abstract

Approximately 1/2 of maxillary and 1/5 of mandibular multi-stranded lingual retainers fail during retention in some form, either bond failure or wire breakage. Memotain is a new CAD/CAM fabricated lingual retainer wire made of custom-cut nickel-titanium, as an alternative to multi-stranded lingual retainers. It offers numerous perceived advantages to the traditional multi-stranded stainless steel wire, including precision fit, avoidance of interferences, corrosion resistance and even the potential for minor tooth movement as an active lingual retainer.
Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28364905     DOI: 10.1016/j.ajodo.2016.11.021

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Comparative assessment of relapse and failure between CAD/CAM stainless steel and standard stainless steel fixed retainers in orthodontic retention patients.

Authors:  Hun Shim; Patrick Foley; Brent Bankhead; Ki Beom Kim
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

2.  Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial.

Authors:  Emilie Gelin; Laurence Seidel; Annick Bruwier; Adelin Albert; Carole Charavet
Journal:  Korean J Orthod       Date:  2020-11-25       Impact factor: 1.372

Review 3.  Efficacy of CAD/CAM Technology in Interventions Implemented in Orthodontics: A Scoping Review of Clinical Trials.

Authors:  Carlos M Ardila; Andrés Elorza-Durán; Daniel Arrubla-Escobar
Journal:  Biomed Res Int       Date:  2022-06-02       Impact factor: 3.246

4.  Biomechanical properties of CAD/CAM-individualized nickel-titanium lingual retainers: an in vitro study.

Authors:  Stephan Christian Möhlhenrich; Fabian Jäger; Andreas Jäger; Pascal Schumacher; Michael Wolf; Ulrike Fritz; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2018-07-16       Impact factor: 1.938

5.  Orthodontic Fixed Retainer and Unwanted Movements of Lower Anterior Teeth: A Case Report.

Authors:  Maria Francesca Sfondrini; Maurizio Pascadopoli; Sergio Beccari; Giovanna Beccari; Cinzia Rizzi; Paola Gandini; Andrea Scribante
Journal:  Case Rep Dent       Date:  2022-09-02

6.  Fixed lingual orthodontic retainer with bilateral missing lateral incisors produced in PEEK material using CAD/CAM technology.

Authors:  Khaled Aboulazm; Constantin von See; Ahmed Othman
Journal:  J Clin Exp Dent       Date:  2021-06-01

7.  Orthodontic retention: what's on the horizon?

Authors:  Simon J Littlewood; Oyku Dalci; Calogero Dolce; L Shannon Holliday; Sasan Naraghi
Journal:  Br Dent J       Date:  2021-06-11       Impact factor: 1.626

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.