Literature DB >> 33587126

Effects of different lingual retainers on periodontal health and stability.

Rabia Adanur-Atmaca, Serpil Çokakoğlu, Fırat Öztürk.   

Abstract

OBJECTIVES: To evaluate the effects of different lingual retainers on periodontal health and stability of mandibular anterior teeth at the 1-year follow-up.
MATERIALS AND METHODS: One hundred thirty-two patients were randomly allocated to four groups using different lingual retainers: group 1, 0.016 × 0.022-in dead-soft wire; group 2, 0.0215-in 5-strand stainless steel wire; group 3, 0.014 × 0.014-in computer-aided design/computer-aided manufacturing nitinol retainer (Memotain); group 4, connected bonding pads. Plaque, gingival, and calculus indexes were used to evaluate periodontal health, and Little's irregularity index, intercanine width, and arch length measurements were performed to evaluate stability. All measurements were performed at each time point (debonding and 3, 6, 9, and 12 months).
RESULTS: The mean value of the gingival index obtained in group 3 was lower than the mean value for all other groups. The mean value of the calculus index was the lowest in group 3, and there was a significant difference between group 3 and groups 1 and 2. No differences were found among the groups in terms of plaque index, intercanine width, and arch length. The least irregularity was obtained in groups 2 and 3. There were no significant differences between these groups and groups 1 and 4.
CONCLUSIONS: Gingival inflammation and calculus accumulation were the lowest in group 3 (Memotain). The irregularity for Memotain and stainless steel retainers was less than or the other groups. However, no clinically significant worsening of periodontal health or relapse were seen in any groups after 1 year.
© 2021 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  CAD/CAM; Fixed retainer; Periodontal health; Stability

Year:  2021        PMID: 33587126     DOI: 10.2319/110220-904.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  2 in total

Review 1.  Efficacy of CAD/CAM Technology in Interventions Implemented in Orthodontics: A Scoping Review of Clinical Trials.

Authors:  Carlos M Ardila; Andrés Elorza-Durán; Daniel Arrubla-Escobar
Journal:  Biomed Res Int       Date:  2022-06-02       Impact factor: 3.246

2.  Clinical Study on Efficiency of Using Traditional Direct Bonding or OrthGuide Computer-Aided Indirect Bonding in Orthodontic Patients.

Authors:  Min Wang; Xing Shi; Wei-Pu Cheng; Fei-Hu Ma; Si-Miao Cheng; Xuan Kang
Journal:  Dis Markers       Date:  2022-09-29       Impact factor: 3.464

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.