| Literature DB >> 35629043 |
Yueh-Ling Chen1,2, Christy Pu3, Ken-Kuo Lin1,2, Jiahn-Shing Lee1,2, Laura Liu1,2, Chiun-Ho Hou1,2,3,4.
Abstract
PURPOSE: To analyze visual quality and contrast sensitivity in patients after intraocular lens (IOL) implantation with sutured scleral fixation.Entities:
Keywords: contrast sensitivity; intraocular lens; scleral fixation; visual quality
Year: 2022 PMID: 35629043 PMCID: PMC9147216 DOI: 10.3390/jcm11102917
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.964
Demographics and visual outcomes of eyes following in-bag and scleral-fixated intraocular lens implantation.
| Characteristics | In-Bag ( | Scleral Fixation ( | |
|---|---|---|---|
| Age in years, mean ± SD (range) | 69.76 ± 9.58 (46–96) | 58.13 ± 12.81 (36–79) | <0.001 * |
| Male sex, No. (male %) | 24 (32.43) | 10 (43.48) | 0.038 * |
| Laterality, No. | 0.509 | ||
| OD (%) | 36 (48.65) | 13 (56.52) | |
| OS (%) | 38 (51.35) | 10 (43.48) | |
| IOL type, No. | 0.003 * | ||
| Spherical (%) | 19 (25.68) | 9 (39.13) | |
| Aspheric (%) | 28 (37.84) | 14 (60.87) | |
| Toric (%) | 27 (36.48) | 0 (0) | |
| Postop in months, mean ± SD (range) | 19.88 ± 30.09 | 16.22 ± 19.27 | 0.585 |
| Pupil size (mm ± SD) | 4.81 ± 1.02 | 4.66 ± 0.99 | 0.526 |
| CDVA (logMAR ± SD) | 0.11 ± 0.14 | 0.20 ± 0.17 | 0.015 * |
| SE, mean ± SD | −0.23 ± 0.75 | −1.09 ± 3.32 | 0.0385 * |
| Astigmatism, mean ± SD | −0.81 ± 0.58 | −1.11 ± 0.87 | 0.0654 |
CDVA = corrected distance visual acuity; IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; OD = right eye; OS = left eye; SD = standard deviation; SE = spherical equivalent; * p < 0.05.
Postoperative ocular, corneal, and internal aberrations for 3-mm pupil diameters in eyes following in-bag and scleral-fixated intraocular lens implantation.
| In-Bag ( | Scleral Fixation ( | ||
|---|---|---|---|
| Ocular | |||
| Aberrations a (μm ± SD) | 0.387 ± 0.194 | 0.785 ± 0.667 | <0.001 * |
| HOAs (μm ± SD) | 0.145 ± 0.070 | 0.255 ± 0.241 | 0.001 * |
| Tilt (μm ± SD) | 0.103 ± 0.064 | 0.187 ± 0.203 | 0.003 * |
| Trefoil (μm ± SD) | 0.121 ± 0.076 | 0.209 ± 0.189 | 0.002 * |
| Coma (μm ± SD) | 0.035 ± 0.024 | 0.058 ± 0.053 | 0.004 * |
| Astigmatism b (μm ± SD) | 0.434 ± 0.211 | 0.704 ± 0.553 | 0.001 * |
| Spherical aberration (μm ± SD) | 0.016 ± 0.013 | 0.022 ± 0.020 | 0.059 |
| Corneal | |||
| Aberrations a (μm ± SD) | 0.377 ± 0.183 | 0.432 ± 0.194 | 0.213 |
| HOAs (μm ± SD) | 0.112 ± 0.049 | 0.146 ± 0.084 | 0.019 * |
| Tilt (μm ± SD) | 0.133 ± 0.102 | 0.167 ± 0.148 | 0.208 |
| Trefoil (μm ± SD) | 0.074 ± 0.042 | 0.102 ± 0.066 | 0.017 * |
| Coma (μm ± SD) | 0.056 ± 0.038 | 0.065 ± 0.060 | 0.355 |
| Astigmatism b (μm ± SD) | 1.201 ± 0.828 | 1.340 ± 0.739 | 0.473 |
| Spherical aberration (μm ± SD) | 0.025 ± 0.024 | 0.035 ± 0.030 | 0.094 |
| Internal | |||
| Aberrations a (μm ± SD) | 0.404 ± 0.204 | 0.714 ± 0.683 | 0.001 * |
| HOAs (μm ± SD) | 0.130 ± 0.066 | 0.209 ± 0.234 | 0.011 * |
| Tilt (μm ± SD) | 0.138 ± 0.110 | 0.178 ± 0.177 | 0.198 |
| Trefoil (μm ± SD) | 0.086 ± 0.061 | 0.151 ± 0.173 | 0.007 * |
| Coma (μm ± SD) | 0.051 ± 0.041 | 0.053 ± 0.037 | 0.830 |
| Astigmatism b (μm ± SD) | 0.858 ± 0.685 | 1.340 ± 1.815 | 0.060 |
| Spherical aberration (μm ± SD) | 0.025 ± 0.024 | 0.035 ± 0.030 | 0.094 |
HOAs = higher-order aberrations; * p < 0.05; a lower and higher-order aberrations included; b astigmatism and secondary astigmatism included.
Postoperative contrast sensitivity of eyes following in-bag and scleral-fixated intraocular lens implantation.
| (AULCSF ± SD) | In-Bag ( | Scleral Fixation ( | |
|---|---|---|---|
| Day (100 cd/m2) | |||
| Glare off | 1.345 ± 0.395 | 1.073 ± 0.549 | 0.011 * |
| Glare on | 1.314 ± 0.333 | 1.065 ± 0.521 | 0.008 * |
| Twilight (10 cd/m2) | |||
| Glare off | 1.179 ± 0.317 | 1.046 ± 0.434 | 0.114 |
| Glare on | 1.060 ± 0.356 | 0.887 ± 0.479 | 0.065 |
| Night (5 cd/m2) | |||
| Glare off | 1.085 ± 0.316 | 0.972 ± 0.371 | 0.157 |
| Glare on | 0.783 ± 0.359 | 0.658 ± 0.443 | 0.173 |
AULCSF = area under the log contrast sensitivity function; * p < 0.05.
Figure 1Forest plot depicts the coefficient of each factor and its 95% confidence interval (CI) in a multiple regression analysis for factors associated with contrast sensitivity. The x-axis represents the reference line (dashed), the value of coefficient (dot), and 95% CI (strip). AULCSF = area under the log contrast sensitivity function; IOL = intraocular lens; LogMAR = logarithm of the minimum angle of resolution.
Multivariate generalized estimating equation (GEE) analysis of contrast sensitivity under every luminance condition with or without glare interference.
| Variables | Day Time | Day Time | Twilight | Twilight | Night Time | Night Time | |
|---|---|---|---|---|---|---|---|
| β (SE) | β (SE) | β (SE) | β (SE) | β (SE) | β (SE) | ||
| Age | −0.008 (0.004) * | −0.008 (0.004) * | −0.005 (0.003) | −0.007 (0.004) | −0.007 (0.003) * | −0.009 (0.004) * | |
| Gender | 0.080 (0.082) | 0.095 (0.076) | −0.027 (0.070) | 0.013 (0.073) | −0.027 (0.069) | 0.030 (0.077) | |
| Surgical technique | −0.127 (0.113) | −0.145 (0.097) | −0.012 (0.085) | −0.014 (0.096) | −0.039 (0.082) | −0.053 (0.102) | |
| Pupil size | 0.069 (0.039) | 0.035 (0.034) | 0.007 (0.029) | 0.014 (0.033) | −0.024 (0.028) | 0.032 (0.035) | |
| IOL type | Aspheric | −0.077 (0.091) | −0.007 (0.082) | 0.097 (0.074) | 0.077 (0.080) | 0.122 (0.072) | 0.075 (0.084) |
| Toric | −0.126 (0.107) | −0.015 (0.093) | 0.036 (0.081) | 0.059 (0.092) | 0.040 (0.078) | 0.042 (0.097) | |
| LogMAR | −0.698 (0.277) * | −0.700 (0.235) ** | −0.590 (0.200) *** | −0.776 (0.234) ** | −0.406 (0.191) ** | −0.677 (0.248) * | |
| Ocular aberrations | −0.460 (0.106) *** | −0.387 (0.090) *** | −0.417 (0.078) *** | −0.458 (0.090) *** | −0.405 (0.075) *** | −0.333 (0.095) *** |
IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; SE = standard error; * p < 0.05; ** p < 0.01; *** p < 0.001.