Literature DB >> 10328384

Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery.

K Hayashi1, H Hayashi, F Nakao, F Hayashi.   

Abstract

OBJECTIVES: To compare the extent of intraocular lens (IOL) tilt and decentration, as well as the anterior chamber depth after trans-scleral suture IOL fixation after either secondary out-of-the-bag or primary in-the-bag IOL implantation.
DESIGN: Retrospective, comparative, nonrandomized, interventional study. PARTICIPANTS: Fifty-two eyes that underwent scleral suture fixation were compared with 51 eyes that underwent secondary out-of-the-bag implantation and 50 eyes that underwent in-the-bag implantation. INTERVENTION: One-piece polymethyl methacrylate IOL implantation by three different techniques. MAIN OUTCOME MEASURES: The tilt angle and decentration length of the IOL, as well as the anterior chamber depth, were measured by the Scheimpflug videophotography system. The spherical equivalent error from the predicted value was also examined.
RESULTS: The mean tilt angle in the scleral suture fixation group was significantly greater than that in either the out-of-the-bag or the in-the-bag implantation group (P<0.0001). The mean decentration length was also largest in the suture group, followed by the out-of-the-bag group and the in-the-bag group (P<0.0001). The anterior chamber depth in the suture group and the out-of-the-bag group was significantly smaller than that in the in-the-bag group (P<0.0001). The spherical equivalent error in the suture group and the out-of-the-bag group was also greater than that in the in-the-bag group (P<0.0001).
CONCLUSIONS: The extent of both tilt and decentration after scleral suture fixation was greater than that observed after either out-of-the-bag or in-the-bag implantation. The anterior chamber depth with the sutured or out-of-the-bag fixated IOL was shallower than that with the in-the-bag fixated IOL, which resulted in a significant myopic shift.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10328384     DOI: 10.1016/S0161-6420(99)00504-7

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  35 in total

1.  Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

Authors:  S Kazemi; W J Wirostko; S Sinha; W F Mieler; S B Koenig; B P Sheth
Journal:  Trans Am Ophthalmol Soc       Date:  2000

2.  Employing endoscopic guidance for placement of a black diaphragm aniridia intraocular lens following destructive Acanthamoeba sclerokeratitis.

Authors:  A M Poothullil; S D McLeod; S Lin
Journal:  Br J Ophthalmol       Date:  2004-04       Impact factor: 4.638

3.  The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation.

Authors:  Burcu Kemer Atik; Cigdem Altan; Alper Agca; Asli Kirmaci; Yusuf Yildirim; Selim Genc; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

4.  [A new posterior chamber intraocular lens for sutureless iris-fixated ciliary sulcus implantation in aphakic eyes without capsular support].

Authors:  P W Rieck; H Binder
Journal:  Ophthalmologe       Date:  2007-07       Impact factor: 1.059

5.  Management of intraoperative tilting of the scleral-fixated intraocular lens in classical aniridia.

Authors:  Hemamalini Arvind; Alex Hunyor; Kathy McClellan; Francis Billson; John Grigg; Robyn Jamieson
Journal:  Br J Ophthalmol       Date:  2007-09       Impact factor: 4.638

6.  Comparison of cornea endothelial cell counts after combined phacovitrectomy versus pars plana vitrectomy with fragmentation.

Authors:  Youngsub Eom; Seong-Woo Kim; Jaemoon Ahn; Jee Taek Kim; Kuhl Huh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-08-15       Impact factor: 3.117

7.  Scleral Fixation of Intraocular Lenses with Gore-Tex Suture: Refractive Outcomes and Comparison of Lens Power Formulas.

Authors:  Benjamin W Botsford; Andrew M Williams; Ian P Conner; Joseph N Martel; Andrew W Eller
Journal:  Ophthalmol Retina       Date:  2019-02-19

8.  Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration.

Authors:  T Oshika; G Sugita; K Miyata; T Tokunaga; T Samejima; C Okamoto; Y Ishii
Journal:  Br J Ophthalmol       Date:  2006-08-16       Impact factor: 4.638

9.  Comparison of outcomes of scleral fixation with and without pars plana vitrectomy for the treatment of dislocated intraocular lens.

Authors:  Seung Yong Choi; You Sook Hwang; Mirinae Kim; Soon Il Choi; Young-Hoon Park
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-09-17       Impact factor: 3.117

10.  Glued intraocular lens implantation for eyes with defective capsules: A retrospective analysis of anatomical and functional outcome.

Authors:  Dhivya A Kumar; Athiya Agarwal; Amar Agarwal; Gaurav Prakash; Soosan Jacob
Journal:  Saudi J Ophthalmol       Date:  2011-04-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.