Literature DB >> 29502212

A comparative study of transscleral suture-fixated and scleral-fixated intraocular lens implantation.

Yu Mizuno1, Yosuke Sugimoto2.   

Abstract

PURPOSE: To compare short-term clinical outcomes between scleral-fixated and transscleral suture-fixated intraocular lens (IOL) implantation. SEETING: Hiroshima Prefectural Hospital, Japan.
DESIGN: A retrospective, nonrandomized, comparative case series.
METHODS: Eighty-nine eyes of 87 patients were included in this study; 45 eyes underwent transscleral suture-fixated IOL implantation (group 1), and 44 eyes underwent scleral-fixated IOL implantation (group 2) between February 2009 and June 2017 in the department of Ophthalmology, Hiroshima Prefectural Hospital, Japan. The postoperative best corrected visual acuity (BCVA), degree of astigmatism, IOL astigmatism (total astigmatism-corneal astigmatism), and refractive error were all measured at 1-week and 1-month intervals.
RESULTS: The mean preoperative BCVA in logarithm of minimum angle of resolution (log MAR) was 0.39 ± 0.56 and 0.46 ± 0.51 in groups 1 and 2, respectively, and the mean postoperative BCVA was 0.25 ± 0.41 and 0.34 ± 0.49 at 1 month. The postoperative degree of astigmatism in group 2 was significantly less than that in group 1 at 1 week and 1 month (p = 0.0046 and p = 0.021, respectively). The postoperative IOL astigmatism in group 2 was significantly less than that in group 1 at 1 week (p = 0.021), while the refractive error between the two groups was not significantly different at 1 week or 1 month.
CONCLUSIONS: Scleral-fixated IOL implantation has equivalent BCVA and refractive error outcomes as transscleral suture-fixated IOL implantation during the early postoperative period without serious complications. Scleral-fixated IOL implantation appears to provide more stable fixation than suture-fixated IOL implantation.

Entities:  

Keywords:  Double-needle technique; Scleral-fixated IOL implantation; Secondary IOL implantation; Transscleral suture-fixated IOL implantation

Mesh:

Year:  2018        PMID: 29502212     DOI: 10.1007/s10792-018-0883-5

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  22 in total

Review 1.  Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology.

Authors:  Michael D Wagoner; Terry A Cox; Reginald George Ariyasu; Deborah S Jacobs; Carol L Karp
Journal:  Ophthalmology       Date:  2003-04       Impact factor: 12.079

Review 2.  Techniques of intraocular lens suspension in the absence of capsular/zonular support.

Authors:  Y M Por; M J Lavin
Journal:  Surv Ophthalmol       Date:  2005 Sep-Oct       Impact factor: 6.048

3.  Late dislocation of scleral-sutured posterior chamber intraocular lenses.

Authors:  Marianne O Price; Francis W Price; Liliana Werner; Cecil Berlie; Nick Mamalis
Journal:  J Cataract Refract Surg       Date:  2005-07       Impact factor: 3.351

4.  Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation.

Authors:  Brendan J Vote; Paris Tranos; Catey Bunce; David G Charteris; Lyndon Da Cruz
Journal:  Am J Ophthalmol       Date:  2006-02       Impact factor: 5.258

5.  Sutureless intrascleral posterior chamber intraocular lens fixation.

Authors:  Scharioth G B Gabor; Mitrofanis M Pavlidis
Journal:  J Cataract Refract Surg       Date:  2007-11       Impact factor: 3.351

6.  Subluxation of suture-fixated posterior chamber intraocular lenses a clinicopathologic study.

Authors:  Parag Parekh; W Richard Green; Walter J Stark; Esen Karamursel Akpek
Journal:  Ophthalmology       Date:  2007-02       Impact factor: 12.079

Review 7.  Sutured posterior chamber intraocular lenses: indications and procedure.

Authors:  S B Hannush
Journal:  Curr Opin Ophthalmol       Date:  2000-08       Impact factor: 3.761

8.  Comparative study of vitrectomy for dropped nucleus with and without the use of perfluorocarbon liquid. Clinical, electrophysiological and visual field outcomes.

Authors:  L Verma; M Gogoi; H K Tewari; A Kumar; D Talwar
Journal:  Acta Ophthalmol Scand       Date:  2001-08

9.  Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses.

Authors:  Cem Evereklioglu; Hamdi Er; Necdet A Bekir; Mehmet Borazan; Ferhat Zorlu
Journal:  J Cataract Refract Surg       Date:  2003-02       Impact factor: 3.351

10.  Hanging by a thread: the long-term efficacy and safety of transscleral sutured intraocular lenses in children (an American Ophthalmological Society thesis).

Authors:  Edward G Buckley
Journal:  Trans Am Ophthalmol Soc       Date:  2007
View more
  5 in total

1.  Long-term outcomes of modified glued versus flanged intrascleral haptic fixation techniques for secondary intraocular lenses.

Authors:  Amy Yuan; Debarshi Mustafi; Michael R Banitt; Kasra A Rezaei
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-04-07       Impact factor: 3.535

2.  Comparison of Clinical Outcomes Between Intracapsular Implantation and Intrascleral Fixation Using the Same Model of Intraocular Lens.

Authors:  Toshiki Torii; Akeno Tamaoki; Takashi Kojima; Taisuke Matsuda; Tatsushi Kaga; Kazuo Ichikawa
Journal:  Clin Ophthalmol       Date:  2020-11-17

3.  A Comparison of Visual Quality and Contrast Sensitivity between Patients with Scleral-Fixated and In-Bag Intraocular Lenses.

Authors:  Yueh-Ling Chen; Christy Pu; Ken-Kuo Lin; Jiahn-Shing Lee; Laura Liu; Chiun-Ho Hou
Journal:  J Clin Med       Date:  2022-05-22       Impact factor: 4.964

4.  Clinical observation of a novel technique: transscleral suture fixation of a foldable 3-looped haptics one-piece posterior chamber intraocular lens implantation through scleral pockets with intact conjunctiva.

Authors:  Shuang Ni; Wei Wang; Xiang Chen; Xingdi Wu; Suhong He; Yajuan Ma; Wen Xu
Journal:  BMC Ophthalmol       Date:  2019-05-09       Impact factor: 2.209

5.  Accuracy of intraocular lens calculation formulas for eyes with insufficient capsular support.

Authors:  Zhouyue Li; Zhangkai Lian; Charlotte Aimee Young; Jing Zhao; Guangming Jin; Danying Zheng
Journal:  Ann Transl Med       Date:  2021-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.