Peng Li1, Jiangbei Qu1, Yiliang He1,2, Zhang Bo1, Mengke Pei1.
Abstract
In recent years, rural sewage treatment facilities have grown rapidly in China, and yet the water quality of the effluent has not been well monitored. The detection of chemical oxygen demand (COD) via ultraviolet-visible (UV-Vis) spectroscopy is an emerging technology with advantages of low cost and easy maintenance, which make it appropriate for the on-line monitoring of effluents from rural sewage treatment facilities. Because there are numerous sewage treatment devices in rural regions and as their locations are usually very scattered, it is difficult to calibrate the COD estimation model for each monitoring site. Hence, a COD estimation model with global calibration is a specific problem for application in rural regions. However, little research was performed on real rural sewage, yet much is desired in terms of the model accuracy and robustness. Consequently, a practical COD detection method with UV-Vis spectroscopy was established in this study. The COD estimation model was globally calibrated with effluents from rural sewage treatment devices. In order to avoid misleading data for evaluating the model performance caused by the differences in the COD concentration range of training sets, two new criteria, namely the Root Mean Square Relative Error (RMSRE) and Relative Error Variance (REV), were proposed to evaluate the model accuracy and robustness. Differences in the organic composition as characterized by excitation-emission matrix (EEM) fluorescence spectroscopy were shown to significantly affect the accuracy of the global calibration model. Through comparison among the methods of the partial least squares (PLS), support vector machine (SVM), and back-propagation neural network, PLS was verified to be able to attain sufficient accuracy and to be suitable for applying to the modeling with global calibration. A simplified modeling method was proposed to replace the absorption spectra at the full wavelength band with the absorbance at some specific wavelengths that were selected by interval partial least-squares regression (iPLSR) and synergy interval partial least-squares regression (siPLSR). In this study, the simplified model was proven to be reliable with three specific wavelengths: 251, 356, and 363 nm. An on-line COD monitor utilizing UV-Vis spectroscopy was thus developed for combining with the global calibration model. This journal is © The Royal Society of Chemistry.Entities:
Year: 2020 PMID: 35517748 PMCID: PMC9054276 DOI: 10.1039/c9ra10732k
Source DB: PubMed Journal: RSC Adv ISSN: 2046-2069 Impact factor: 4.036
Criteria of COD estimation models with different data sets
| Date set | A1 | A2 | A3 | C | ||||
|---|---|---|---|---|---|---|---|---|
| Cal. | Val. | Cal. | Val. | Cal. | Val. | Cal. | Val. | |
| RMSE | 6.622 | 6.508 | 9.972 | 10.725 | 12.121 | 12.988 | 5.170 | 5.684 |
|
| 0.843 | 0.887 | 0.949 | 0.921 | 0.743 | 0.790 | 0.933 | 0.876 |
| RMSRE | 0.141 | 0.137 | 0.137 | 0.143 | 0.138 | 0.140 | 0.104 | 0.106 |
| REV | 0.0187 | 0.0199 | 0.0193 | 0.0178 | 0.0178 | 0.0183 | 0.011 | 0.0116 |
Performances of the COD estimation model according to PLS, SVM, and BP-neural network with the criteria of R2, REV, RMSE, and RMSRE
| Methods | PLS | SVM | BP-neural network | |||
|---|---|---|---|---|---|---|
| Cal. | Val. | Cal. | Val. | Cal. | Val. | |
| RMSE | 11.03 | 10.384 | 10.88 | 11.472 | 11.797 | 10.650 |
|
| 0.949 | 0.945 | 0.953 | 0.931 | 0.942 | 0.979 |
| RMSRE | 0.159 | 0.151 | 0.1625 | 0.1737 | 0.1696 | 0.1495 |
| REV | 0.023 | 0.0224 | 0.0237 | 0.025 | 0.0238 | 0.0213 |
Fig. 1Correlation between the UV254 and COD concentration (potassium hydrogen phthalate solution).
Values of the applied criteria for each data set
| Data set | A | C | ||
|---|---|---|---|---|
| Cal. | Val. | Cal. | Val. | |
| RMSE | 11.990 | 10.720 | 5.270 | 4.640 |
|
| 0.943 | 0.934 | 0.928 | 0.955 |
| RMSRE | 0.139 | 0.109 | 0.119 | 0.099 |
| REV | 0.019 | 0.011 | 0.014 | 0.008 |
Fig. 2Distribution of FRI in non-fractionated DOM from Group A and Group C water samples.
Fig. 3UV-visible absorption spectra of all samples.
REV and RMSRE of the optimal model with different amounts of interval combinations
| RMSRE | REV | |||
|---|---|---|---|---|
| Cal. | Val. | Cal. | Val. | |
| One interval | 0.17 | 0.16 | 0.025 | 0.022 |
| Two intervals | 0.13 | 0.135 | 0.018 | 0.0163 |
| Three intervals | 0.124 | 0.133 | 0.015 | 0.0165 |
| Four intervals | 0.146 | 0.14 | 0.021 | 0.02 |
| Five intervals | 0.152 | 0.148 | 0.022 | 0.024 |
| All data | 0.121 | 0.12 | 0.014 | 0.0135 |
Fig. 4Comparison between predicted COD concentrations and the true COD concentrations.
Comparison between the predicted COD concentrations and the true COD concentrations
| True COD (mg L−1) | Predicted COD (mg L−1) | Relative error |
|---|---|---|
| 32.0 | 30.7 | −4.1% |
| 40.0 | 42.2 | 5.5% |
| 66.0 | 83.6 | 26.7% |
| 79.0 | 83.9 | 6.2% |
| 90.0 | 93.8 | 4.2% |
| 130.0 | 127.3 | −2.1% |
| 154.0 | 160.4 | 4.2% |
| 59.0 | 61.1 | 3.6% |
| 60.0 | 71.4 | 19% |
| 199.0 | 193.3 | −2.9% |