Literature DB >> 15566187

Monitoring of COD as an organic indicator in waste water and treated effluent by fluorescence excitation-emission (FEEM) matrix characterization.

S Lee1, K H Ahn.   

Abstract

The fluorescence excitation-emission matrices (FEEM) of domestic waste water, treated effluent of a waste water treatment plant and receiving river water were analyzed to select wavelengths for the monitoring of organic contents as COD. Excitation/emission wavelengths of 220/350 nm and 270/350 nm for protein-like fluorescence and 240/450 nm and 340/450 nm for humic-like fluorescence were suggested as fluorescence peak emitting wavelength pairs, respectively. Without any pre-treatment, the protein-like fluorescence peaks showed better correlation between COD values and fluorescence intensities than the humic-like fluorescence peaks. No enhanced correlation was observed by removing the suspended solids from the samples using filtration. However, statistical multiple regression methods, using the fluorescence intensities from each peak and the light scattering intensity at 633 nm as variables, resulted in an enhanced correlation, with r2 > 0.9 for the measured and predicted COD values.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15566187

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  6 in total

1.  Spectroscopic distribution of dissolved organic matter in a dam reservoir impacted by turbid storm runoff.

Authors:  Jin Hur; Nahm-Chung Jung; Jae-Ki Shin
Journal:  Environ Monit Assess       Date:  2007-02-08       Impact factor: 2.513

2.  Absorption and fluorescence properties of chromophoric dissolved organic matter: implications for the monitoring of water quality in a large subtropical reservoir.

Authors:  Xiaohan Liu; Yunlin Zhang; Kun Shi; Guangwei Zhu; Hai Xu; Mengyuan Zhu
Journal:  Environ Sci Pollut Res Int       Date:  2014-07-23       Impact factor: 4.223

3.  Estimating the biodegradability of treated sewage samples using synchronous fluorescence spectra.

Authors:  Tien M Lai; Jae-Ki Shin; Jin Hur
Journal:  Sensors (Basel)       Date:  2011-07-25       Impact factor: 3.576

4.  Estimation of biological oxygen demand and chemical oxygen demand for combined sewer systems using synchronous fluorescence spectra.

Authors:  Jin Hur; Bo-Mi Lee; Tae-Hwan Lee; Dae-Hee Park
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

5.  Study on an Online Detection Method for Ground Water Quality and Instrument Design.

Authors:  Xiushan Wu; Renyuan Tong; Yanjie Wang; Congli Mei; Qing Li
Journal:  Sensors (Basel)       Date:  2019-05-09       Impact factor: 3.576

6.  Global calibration model of UV-Vis spectroscopy for COD estimation in the effluent of rural sewage treatment facilities.

Authors:  Peng Li; Jiangbei Qu; Yiliang He; Zhang Bo; Mengke Pei
Journal:  RSC Adv       Date:  2020-06-01       Impact factor: 4.036

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.