Development of correlation spectroscopy (COS) method for analyzing fluorescence excitation emission matrix (EEM): A case study of effluent organic matter (EfOM) ozonation.

Huarong Yu1, Fangshu Qu2, Xiaolei Zhang3, Senlin Shao4, Hongwei Rong1, Heng Liang5, Langming Bai6, Jun Ma5.   

Abstract

Two-dimensional correlation spectroscopy (2DCOS) has been used as a powerful tool for analyzing spectral features, but it has never been applied to fluorescence excitation-emission matrix (EEM) data due to the incompatible dimensions. This study first investigated EEM-COS by reducing the dimensions of the EEM (using parallel factor analysis, PARAFAC) for fitting to 2DCOS (EEM-PARAFAC-COS). The fluorescence changes of effluent organic matter (EfOM) during ozonation were studied using EEM-COS and synchronous fluorescence (SF)-2DCOS. The conventionally used SF-2DCOS proved to be biased due to the intrinsic drawback of SF, while the EEM-PARAFAC-COS gave accurate and trustworthy results. Homo-EEM-PARAFAC-COS indicated that the fluorescence protein-like and fulvic-like substances in EfOM were preferentially ozonated compared to humic-like substances. Hetero-EEM-PARAFAC-COS analyses on the EEM, FTIR, UV-vis absorbance, and size-exclusion chromatography showed that the fluorescence protein-like and fulvic-like substances in EfOM were associated with lower molecular weight (MW, ∼0.95 kDa), UV absorbance at ∼280 nm, and more electron-enriched aromatics (with amide and phenolic groups), which explained their ozonation preference, while humic-like substances were related to carboxylic groups, UV absorbance at ∼255 nm, and organics at MW of ∼4.50 kDa. This work demonstrated the great potential of EEM-PARAFAC-COS in studying fluorescence change and correlating fluorescence with other spectra.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Effluent organic matter (EfOM); Excitation-emission matrix (EEM); Parallel factor analysis (PARAFAC); Synchronous fluorescence (SF); Two-dimensional correlation spectroscopy (2DCOS)

Mesh:

Substances:

Year:  2019        PMID: 31022618     DOI: 10.1016/j.chemosphere.2019.04.119

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  1 in total

1.  Global calibration model of UV-Vis spectroscopy for COD estimation in the effluent of rural sewage treatment facilities.

Authors:  Peng Li; Jiangbei Qu; Yiliang He; Zhang Bo; Mengke Pei
Journal:  RSC Adv       Date:  2020-06-01       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.