Recent UV-visible spectrometers deliver on line and in situ absorbance spectra in wastewater or stormwater transported in urban drainage systems. After calibration with local data sets, spectra can be used to estimate pollutant concentrations. Calibration methods are usually based on PLS (Partial Least Squares) regression. Their most important difficulty lies in the identification of the number of both i) the latent vectors and ii) the independent variables. A method is proposed to identify these variables, based on an exhaustive tests procedure (Jackknife cross validation and matrix of prediction indicator). It was applied to estimate TSS (total suspended solids) or COD (chemical oxygen demand) concentrations at the inlet of a storage-settling tank in a stormwater separate sewer system, and compared to three other calibration methods used either for turbidity meters or UV-visible spectrometers. With the available calibration data set: i) the spectrometer gives results with better prediction quality than the turbidity meter, ii) for the spectrometer, local calibration gives better results than global calibration, iii) the proposed PLS method gives results with a similar order of magnitude in uncertainties as the manufacturer local calibration method, but is more open and transparent for the user. Similar results were obtained for a second data set.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18359999     DOI: 10.2166/wst.2008.131

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  4 in total

1.  Comparison of artificial neural network (ANN) and partial least squares (PLS) regression models for predicting respiratory ventilation: an exploratory study.

Authors:  Ming-I Brandon Lin; William A Groves; Andris Freivalds; Eun Gyung Lee; Martin Harper
Journal:  Eur J Appl Physiol       Date:  2011-08-23       Impact factor: 3.078

2.  Use of ultraviolet-visible spectrophotometry associated with artificial neural networks as an alternative for determining the water quality index.

Authors:  Edson Marcelino Alves; Ramon Juliano Rodrigues; Caroline Dos Santos Corrêa; Tiago Fidemann; José Celso Rocha; José Leonel Lemos Buzzo; Pedro de Oliva Neto; Eutimio Gustavo Fernández Núñez
Journal:  Environ Monit Assess       Date:  2018-05-02       Impact factor: 2.513

3.  Assessment of pollutant load emission from combined sewer overflows based on the online monitoring.

Authors:  Agnieszka Brzezińska; Marek Zawilski; Grażyna Sakson
Journal:  Environ Monit Assess       Date:  2016-08-03       Impact factor: 2.513

4.  Global calibration model of UV-Vis spectroscopy for COD estimation in the effluent of rural sewage treatment facilities.

Authors:  Peng Li; Jiangbei Qu; Yiliang He; Zhang Bo; Mengke Pei
Journal:  RSC Adv       Date:  2020-06-01       Impact factor: 4.036