Literature DB >> 24468377

Development of variable pathlength UV-vis spectroscopy combined with partial-least-squares regression for wastewater chemical oxygen demand (COD) monitoring.

Baisheng Chen1, Huanan Wu2, Sam Fong Yau Li3.   

Abstract

To overcome the challenging task to select an appropriate pathlength for wastewater chemical oxygen demand (COD) monitoring with high accuracy by UV-vis spectroscopy in wastewater treatment process, a variable pathlength approach combined with partial-least squares regression (PLSR) was developed in this study. Two new strategies were proposed to extract relevant information of UV-vis spectral data from variable pathlength measurements. The first strategy was by data fusion with two data fusion levels: low-level data fusion (LLDF) and mid-level data fusion (MLDF). Predictive accuracy was found to improve, indicated by the lower root-mean-square errors of prediction (RMSEP) compared with those obtained for single pathlength measurements. Both fusion levels were found to deliver very robust PLSR models with residual predictive deviations (RPD) greater than 3 (i.e. 3.22 and 3.29, respectively). The second strategy involved calculating the slopes of absorbance against pathlength at each wavelength to generate slope-derived spectra. Without the requirement to select the optimal pathlength, the predictive accuracy (RMSEP) was improved by 20-43% as compared to single pathlength spectroscopy. Comparing to nine-factor models from fusion strategy, the PLSR model from slope-derived spectroscopy was found to be more parsimonious with only five factors and more robust with residual predictive deviation (RPD) of 3.72. It also offered excellent correlation of predicted and measured COD values with R(2) of 0.936. In sum, variable pathlength spectroscopy with the two proposed data analysis strategies proved to be successful in enhancing prediction performance of COD in wastewater and showed high potential to be applied in on-line water quality monitoring.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemical oxygen demand (COD); Data fusion; Partial-least-squares regression (PLSR); Slope-derived spectroscopy; Wastewater quality monitoring

Mesh:

Substances:

Year:  2013        PMID: 24468377     DOI: 10.1016/j.talanta.2013.12.026

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Study on an Online Detection Method for Ground Water Quality and Instrument Design.

Authors:  Xiushan Wu; Renyuan Tong; Yanjie Wang; Congli Mei; Qing Li
Journal:  Sensors (Basel)       Date:  2019-05-09       Impact factor: 3.576

2.  Capturing the Geoherbalism Differentiation in Wild Paris polyphylla var. yunnanensis Raw Materials through the Application of Multispectral Information Fusion Combined with Chemometrics.

Authors:  Yuanzhong Wang; Yan Li; Jinyu Zhang
Journal:  ACS Omega       Date:  2019-11-01

3.  Global calibration model of UV-Vis spectroscopy for COD estimation in the effluent of rural sewage treatment facilities.

Authors:  Peng Li; Jiangbei Qu; Yiliang He; Zhang Bo; Mengke Pei
Journal:  RSC Adv       Date:  2020-06-01       Impact factor: 4.036

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.