Literature DB >> 35404807

High-Density MRI RF Arrays Using Mixed Dipole Antennas and Microstrip Transmission Line Resonators.

Ming Lu, Saikat Sengupta, John C Gore, William A Grissom, Xinqiang Yan.   

Abstract

OBJECTIVE: High-density multi-coil arrays are desirable in MRI because they provide high signal-to-noise ratios (SNR), enable highly accelerated parallel imaging, and provide more uniform transmit fields at high fields. For high-density arrays such as a head array with 16 elements in a row, popular dipole antennas and microstrip transmission line (also referred to as "MTL") resonators both have severe coupling issues.
METHODS: In this work, we show that dipoles and MTLs have naturally low coupling and propose a novel array configuration in which they are interleaved. We first show the electromagnetic (EM) coupling between a single dipole and a single MTL across different separations in bench tests. Then we validate and analyze this through EM simulations. Finally, we construct a 16-channel mixed dipole and MTL array and evaluate its performance on the bench and through MRI experiments.
RESULTS: Without any decoupling treatments, the worst coupling between a dipole and an MTL was only -15.8 dB when their center-to-center distance was 4.7 cm (versus -5.4 dB for two dipole antennas and -6.0 dB for two MTL resonators). Even in a dense 16-channel mixed array, the inter-element isolation among all elements was better than -14 dB.
CONCLUSION: This study reveals, analyzes, and validates a novel finding that the popular dipole antennas and MTL resonators used in ultrahigh field MRI have naturally low coupling. SIGNIFICANCE: These findings will simplify the construction of high-density arrays, enable new applications, and benefit imaging performance in ultrahigh field MRI.

Entities:  

Mesh:

Year:  2022        PMID: 35404807      PMCID: PMC9587496          DOI: 10.1109/TBME.2022.3166279

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.756


  55 in total

1.  Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90 degrees " RF pulse for the head in the birdcage coil.

Authors:  C M Collins; M B Smith
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

3.  DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

Authors:  Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2012-01-17       Impact factor: 4.668

4.  An inverted-microstrip resonator for human head proton MR imaging at 7 tesla.

Authors:  Xiaoliang Zhang; Kamil Ugurbil; Robert Sainati; Wei Chen
Journal:  IEEE Trans Biomed Eng       Date:  2005-03       Impact factor: 4.538

5.  16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

Authors:  Celal Oezerdem; Lukas Winter; Andreas Graessl; Katharina Paul; Antje Els; Oliver Weinberger; Jan Rieger; Andre Kuehne; Matthias Dieringer; Fabian Hezel; Dirk Voit; Jens Frahm; Thoralf Niendorf
Journal:  Magn Reson Med       Date:  2015-07-17       Impact factor: 4.668

6.  Ratio-adjustable power splitters for array-compressed parallel transmission.

Authors:  Xinqiang Yan; Zhipeng Cao; William A Grissom
Journal:  Magn Reson Med       Date:  2017-07-31       Impact factor: 4.668

7.  Experimental implementation of array-compressed parallel transmission at 7 tesla.

Authors:  Xinqiang Yan; Zhipeng Cao; William A Grissom
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

8.  Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: early experiments and simulations at 3 T.

Authors:  Wei Luo; Michael T Lanagan; Christopher T Sica; Yeunchul Ryu; Sukhoon Oh; Matthew Ketterman; Qing X Yang; Christopher M Collins
Journal:  Magn Reson Med       Date:  2012-08-13       Impact factor: 4.668

9.  A radiofrequency coil configuration for imaging the human vertebral column at 7 T.

Authors:  M Vossen; W Teeuwisse; M Reijnierse; C M Collins; N B Smith; A G Webb
Journal:  J Magn Reson       Date:  2010-12-04       Impact factor: 2.229

10.  Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit/receive array.

Authors:  Zhipeng Cao; Joshua Park; Zang-Hee Cho; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2014-06-27       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.