An inverted-microstrip resonator for human head proton MR imaging at 7 tesla.

Xiaoliang Zhang1, Kamil Ugurbil, Robert Sainati, Wei Chen.   

Abstract

As an extension of the previously developed microstrip transmission line (MTL) RF coil design, a high-frequency RF volume coil using multiple inverted MTL (iMTL) resonators for human head imaging at high magnetic field strength of 7 tesla (T) is reported. Compared to conventional MTL resonators, iMTL resonators can operate at higher frequency with lower losses and, thus, are suitable for designs of high-frequency RF volume coils with large coil size for human MR imaging and spectroscopy at high fields. An approach using capacitive terminations was analyzed and applied to the design of the iMTL volume coil for improving RF field homogeneity and broadening frequency-tuning range. A performance-comparison study was conducted between the prototype iMTL volume coil and a custom-built TEM volume coil at 7 T. The iMTL volume coil presents a comparable SNR and intrinsic B1 homogeneity to the TEM volume coil. Phantom and the human head images acquired using the iMTL volume coil are also presented. The proposed iMTL volume coil provides an efficient and alternative solution to design high-frequency and large-size volume coils for human MR applications at very high fields.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15759580     DOI: 10.1109/TBME.2004.842968

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  38 in total

1.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

2.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

3.  Stripline resonator and preamplifier for preclinical magnetic resonance imaging at 4.7 T.

Authors:  Ioannis Lavdas; Hugh C Seton; Charles R Harrington; Claude M Wischik
Journal:  MAGMA       Date:  2011-08-04       Impact factor: 2.310

4.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

5.  Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

Authors:  Xiaoliang Zhang; Alastair Martin; Caroline Jordan; Prasheel Lillaney; Aaron Losey; Yong Pang; Jeffrey Hu; Mark Wilson; Daniel Cooke; Steven W Hetts
Journal:  Quant Imaging Med Surg       Date:  2017-04

6.  Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

Authors:  Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2017-04

7.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

8.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

9.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

10.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.