Literature DB >> 3524634

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

I A Simpson, I J Reece, A B Houston, I Hutton, D J Wheatley, S M Cobbe.   

Abstract

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than across the Wessex porcine or Hancock pericardial valves. Mitral pressure half time was, however, significantly longer in the Hancock pericardial than in the Wessex porcine or Ionescu-Shiley valves. No significant differences were seen among the groups of aortic bioprostheses, though the comparable size of Wessex porcine valves showed significantly higher gradients. Bioprosthetic regurgitation was detected in 13 of 103 mitral and 11 of 59 aortic valves, though it was suspected clinically in only 12 mitral and six aortic bioprostheses. Doppler ultrasound is a repeatable non-invasive method of acquiring haemodynamic information in vivo from a variety of bioprostheses and it can detect bioprosthetic regurgitation at an early stage.

Entities:  

Mesh:

Year:  1986        PMID: 3524634      PMCID: PMC1277389          DOI: 10.1136/hrt.56.1.83

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  23 in total

1.  Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique.

Authors:  J Holen; R Aaslid; K Landmark; S Simonsen
Journal:  Acta Med Scand       Date:  1976

2.  Determination of pressure gradient in mitral stenosis with Doppler echocardiography.

Authors:  J Holen; S Simonsen
Journal:  Br Heart J       Date:  1979-05

3.  An ultrasound Doppler technique for the noninvasive determination of the pressure gradient in the Björk-Shiley mitral valve.

Authors:  J Holen; S Simonsen; T Frøysaker
Journal:  Circulation       Date:  1979-03       Impact factor: 29.690

4.  Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves.

Authors:  G A Williams; A J Labovitz
Journal:  Am J Cardiol       Date:  1985-08-01       Impact factor: 2.778

5.  Non-invasive diagnosis of mitral regurgitation by Doppler echocardiography.

Authors:  D Blanchard; B Diebold; P Peronneau; J M Foult; M Nee; J L Guermonprez; P Maurice
Journal:  Br Heart J       Date:  1981-05

6.  Non-invasive assessment of aortic stenosis by Doppler ultrasound.

Authors:  L Hatle; B A Angelsen; A Tromsdal
Journal:  Br Heart J       Date:  1980-03

7.  Hemodynamic performance of the Ionescu-Shiley valve prosthesis.

Authors:  R M Becker; J Strom; W Frishman; Y Oka; Y T Lin; E L Yellin; R W Frater
Journal:  J Thorac Cardiovasc Surg       Date:  1980-10       Impact factor: 5.209

8.  Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound.

Authors:  L Hatle; B Angelsen; A Tromsdal
Journal:  Circulation       Date:  1979-11       Impact factor: 29.690

9.  Obstructic characteristics of Björk-Shiley, Hancock, and Lillehei-Kaster prosthetic mitral valves in the immediate postoperative period.

Authors:  J Holen; J Hìe; B Semb
Journal:  Acta Med Scand       Date:  1978

10.  Detection and estimation of the degree of mitral regurgitation by range-gated pulsed doppler echocardiography.

Authors:  A S Abbasi; M W Allen; D DeCristofaro; I Ungar
Journal:  Circulation       Date:  1980-01       Impact factor: 29.690

View more
  4 in total

1.  Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.

Authors:  J Chambers; G Jackson; D Jewitt
Journal:  Br Heart J       Date:  1990-03

2.  Effect of changes in heart rate on pressure half time in normally functioning mitral valve prostheses.

Authors:  J Chambers; N McLoughlin; A Rapson; G Jackson
Journal:  Br Heart J       Date:  1988-12

3.  How to quantitate valve regurgitation by echo Doppler techniques. British Society of Echocardiography.

Authors:  I A Simpson; M A de Belder; A Kenny; M Martin; P Nihoyannopoulos
Journal:  Br Heart J       Date:  1995-05

Review 4.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.