| Literature DB >> 35129628 |
Yuhao Ye1,2,3, Jing Zhao1,2,3, Zhe Zhang1,2,3, Lingling Niu1,2,3, Wanru Shi1,2,3, Xiaoying Wang1,2,3, Xingtao Zhou4,5,6.
Abstract
PURPOSE: To investigate the long-term safety and efficacy of monovision surgery using implantable collamer lens V4c (ICL V4c) implantation in myopic patients with early presbyopia.Entities:
Keywords: Efficacy; Implantable collamer lens; Monovision; Myopia; Presbyopia; Safety
Mesh:
Year: 2022 PMID: 35129628 PMCID: PMC9325784 DOI: 10.1007/s00417-021-05545-x
Source DB: PubMed Journal: Graefes Arch Clin Exp Ophthalmol ISSN: 0721-832X Impact factor: 3.535
Preoperative patient demographics
| Characteristic | Mean ± SD | Range |
|---|---|---|
| Age (years) | 43.50 ± 2.61 | [40, 50] |
| Gender (male/female) | 12/20 | |
| Axial length (mm) | 28.86 ± 2.35 | [24.99, 32.96] |
| Refraction sphere (D) | − 11.72 ± 3.62 | [− 19.50, − 4.00] |
| Refraction cylinder (D) | − 1.32 ± 0.98 | [− 3.50, 0] |
| Spherical equivalent, SE (D) | − 12.37 ± 3.67 | [− 20.00, − 5.63] |
| Dominant eye (OD/OS) | 15/17 | |
| K-flat (D) | 42.99 ± 1.67 | [39.50, 46.90] |
| K-steep (D) | 44.49 ± 1.90 | [40.50, 47.30] |
| CT (mm) | 0.52 ± 0.33 | [0.460, 0.590] |
| ATA, vertical (mm) | 12.41 ± 0.60 | [11.19, 14.80] |
| ATA, horizontal (mm) | 11.91 ± 0.54 | [10.94, 14.17] |
| WTW (mm) | 11.64 ± 0.40 | [10.90, 12.80] |
SE, spherical equivalent; IOP, intraocular pressure; CDVA, corrected-distant visual acuity; CT, corneal thickness; ATA, angle to angle distance; WTW, white to white distance
The clinical parameters of the dominant eyes or nondominant eyes before and after the implantable collamer Lens V4c implantation
| Characteristic | D- or nD-eye | Preoperative | 1-mon follow-up | 3-mon follow-up | Last follow-up |
|---|---|---|---|---|---|
| UDVA (Logmar) | D-eye nD-eye | NA | − 0.03 ± 0.08# 0.08 ± 0.13# | − 0.02 ± 0.10* 0.06 ± 0.14* | 0.06 ± 0.15*▵▴ 0.20 ± 0.19*▵▴ |
| SE (D) | D-eye nD-eye | − 12.00 ± 3.66# − 12.74 ± 3.70# | − 0.14 ± 0.35#* − 0.69 ± 0.64#* | − 0.19 ± 0.15#* − 0.72 ± 0.73#* | − 0.62 ± 0.47#*▵▴ − 1.21 ± 0.78#*▵▴ |
| CDVA (Logmar) | D-eye nD-eye | 0.02 ± 0.08# 0.03 ± 0.09# | − 0.05 ± 0.06* − 0.03 ± 0.06* | − 0.05 ± 0.07* − 0.03 ± 0.07* | − 0.06 ± 0.47* − 0.06 ± 0.08* |
| Safety indices | D-eye nD-eye | NA | 1.19 ± 0.17 1.15 ± 0.18 | 1.19 ± 0.18 1.16 ± 0.24 | 1.23 ± 0.18 1.21 ± 0.18 |
| Efficacy indices | D-eye nD-eye | NA | 1.14 ± 0.19# 0.92 ± 0.26# | 1.12 ± 0.24# 0.96 ± 0.26# | 0.95 ± 0.27#▵▴ 0.92 ± 0.28#▵▴ |
D-eye, dominant eye; nD-eye, nondominant eye; UDVA, uncorrected distance visual acuity; SE, spherical equivalent; CDVA, corrected distance visual acuity
*Versus preoperative, p < 0.05
▵The last follow-up versus the 1-month follow-up, p < 0.05
▴The last follow-up versus the 3-month follow-up, p < 0.05
#Dominant eye versus nondominant eye, p < 0.05
Fig. 1Clinical outcomes of 64 eyes (32 dominant eyes and 32 nondominant eyes) with myopia at the last follow-up after the implantation of Implantable Collamer Lens V4c
Fig. 2Uncorrected distance visual acuity at near and far distances at 43 months after hole implantable collamer lens V4c (ICL V4c) implantation. A Last follow-up UDVA (logMAR) of Dominant eyes, nondominant eyes and binocular. B Last follow-up UDVA (Snellen) of the dominant eyes. C Last follow-up UDVA (Snellen) of the nondominant eyes. D Last follow-up binocular UDVA (Snellen)
The clinical parameters and biometric values of the eyes before and after the implantable collamer lens V4C implantation
| Characteristic | Preoperative | 1-mo follow-up | 3-mo follow-up | Last follow-up |
|---|---|---|---|---|
CDVA (Logmar) Range [min, max] | 0.02 ± 0.08 [− 0.08, 0.15] | − 0.04 ± 0.06* [− 0.18, 0.10] | − 0.04 ± 0.07* [− 0.18, 0.10] | − 0.06 ± 0.08* [− 0.18, 0.15] |
Spherical equivalent, SE (D) Range [min, max] | 12.37 ± 3.67 [− 20.00, − 5.63] | − 0.41 ± 0.58* [− 2.25, 0.50] | − 0.45 ± 0.65* [− 2.50, 1.00] | − 0.91 ± 0.70*▵▴ [− 2.63, 0.00] |
Presbyopic add power (D) Range [min, max] | 0.69 ± 0.41 [0.50, 2.25] | NA | NA | 1.31 ± 0.58* [0.50, 2.25] |
ACD (mm) Range [min, max] | 3.21 ± 0.31 [2.78, 3.97] | 3.00 ± 0.32* [2.02, 3.86] | 3.00 ± 0.32* [2.02, 3.81] | 2.99 ± 0.31* [2.05, 3.81] |
IOP (mmHg) Range [min, max] | 14.91 ± 2.67 [8.40, 20.10] | 14.29 ± 2.06 [10.40, 18.80] | 14.71 ± 2.38 [9.4, 19.20] | 15.07 ± 2.65 [9.90, 20.90] |
ACV (μl) Range [min, max] | 192.54 ± 33.33 [121.00, 295.00] | 113.58 ± 22.78* [72.00, 190.00] | 114.08 ± 22.57* [77.00, 198.00] | 121.14 ± 22.08* [78.00, 186.00] |
ACA (°) Range [min, max] | 37.98 ± 5.31 [27.00, 47.30] | 22.48 ± 4.56* [13.20, 31.00] | 22.04 ± 4.35* [14.00, 30.20] | 22.63 ± 3.51* [16.00, 28.20] |
ECD (cell/mm2) Range [min, max] | 3008.84 ± 550.57 [2259.00, 4595.00] | NA | 2760.61 ± 404.99* [2125.00, 3932.00] | 2525.34 ± 248.84*▴ [2047.00, 3198.00] |
Vault (μm) Range [min, max] | NA | 546.88 ± 184.65 [200.00, 880.00] | 537.66 ± 179.52 [200.00, 830.00] | 491.88 ± 206.24 [170.00 ± 860.00] |
CDVA. corrected distance visual acuity; SE. spherical equivalent; ACD, anterior chamber depth; IOP, intraocular pressure; ACA, anterior chamber angle; ACV, anterior chamber volume; ECD, endothelium cell density
*Versus [reoperative, p < 0.05
▵The last follow-up versus the 1-month follow-up, p < 0.05
▴The last follow-up versus the 3-month follow-up, p < 0.05
Fig. 3Subjective visual acuity satisfaction at near and far distances. **p < 0.01, ***preop vs. postop, p < 0.001