Literature DB >> 34870124

Assessment of lower limb peripheral nerves with ultrasound in patients with traumatic amputation.

İlkay Karabay1, Yasin Demir1, Özlem Köroğlu1, Sefa Gümrük Aslan1, Koray Aydemir1, Eda Gürçay1.   

Abstract

OBJECTIVES: This study aims to assess the sciatic nerve (SN), common peroneal nerve (CPN), and tibial nerve (TN) by ultrasound in patients with traumatic lower limb amputation (LLA) and to examine the possible relationship between ultrasonographic and clinical findings. PATIENTS AND METHODS: This cross-sectional study included a total of 33 male patients (mean age: 36.6±8.7 years; range, 21 to 48 years) who had LLA due to traumatic injury between May 2019 and April 2020. Amputation and prosthesis use and functional K level of activity were recorded. Ultrasound examinations were performed to measure the cross-sectional areas (CSAs) of the SN, CPN, and TN bilaterally at the same levels. The values from the normal sides were accepted as controls.
RESULTS: The CSA values were greater on the amputated sides than the non-amputated sides for SN (p=0.001), TN (p=0.001), and CPN (p=0.015), regardless of the activity level. The amputated side SN (p=0.001), TN (p=0.001), and CPN (p=0.016) were thicker in patients with level of K4 activity than the non-amputated side. For the patients with K3 activity level, larger TN CSA values were determined on the amputated side, compared to those at the K4 level (p=0.035). The SN was found to be greater in patients using microprocessor-controlled knee prosthesis (p=0.032) and TN was larger in hypobaric sealing membrane users on the amputated sides (p=0.041).
CONCLUSION: The SN, CPN, and TN were found to be larger in all patients on the amputated sides and in patients with K4 activity level. Based on these findings, the K3 activity level and the use of hypobaric sealing membrane seems to affect the CSA values of TN. Additionally, the use of microprocessor knee prosthesis affects the CSA values of SN. We believe that these results may be essential for the analysis or prediction of lower extremity nerve involvement according to the K activity level and the use of prosthesis in patients with traumatic LLA.
Copyright © 2021, Turkish Society of Physical Medicine and Rehabilitation.

Entities:  

Keywords:  Activity level; amputation; lower limb; peripheral nerve; ultrasound

Year:  2021        PMID: 34870124      PMCID: PMC8606988          DOI: 10.5606/tftrd.2021.7926

Source DB:  PubMed          Journal:  Turk J Phys Med Rehabil        ISSN: 2587-1250


Introduction

Lower limb amputation (LLA) commonly affects young and active individuals who have a long life expectancy. It is a major surgery causing many functional deficiencies which can impair overall health quality and physical condition of the patients and necessitating a multidisciplinary rehabilitation program.[1] Pain, psychological illness, insulin resistance, blood hypercoagulability, and metabolic syndrome are the most frequent drawbacks after LLA.[2] High-frequency ultrasonography is useful in the evaluation of peripheral nerves, as it has many advantages over other techniques. It has high resolution and does not contain ionizing radiation. In addition, dynamic and real-time visualization is possible.[3] Ultrasound has been shown to have the same specificity and sensitivity as magnetic resonance imaging in assessing peripheral nerves.[4] In the literature, there are studies evaluating peripheral nerves in entrapment disorders, immune- mediated neuropathies, traumatic injuries, and neuromuscular disorders.[5] The cross-sectional area (CSA) of a peripheral nerve is the most accepted parametric quantity as a reference for the size of a peripheral nerve, and increased CSA evaluates pathology. Sonographic imaging of the sciatic nerve (SN) after LLA due to malignant causes has been presented.[6] The SN has been also examined in patients with LLA[7] and unilateral sciatica[8] using ultrasound to determine whether ultrasonographic findings are related to clinical characteristics. However, there is no study in the literature investigating the CSA of the SN, common peroneal nerve (CPN), and tibial nerve (TN) sonographically combined with functional activity levels reflecting the clinical condition of patients with traumatic LLA. In the present study, we, therefore, aimed to assess the SN, CPN, and TN by ultrasound in patients with traumatic LLA and to examine the possible relationship between ultrasonographic and clinical findings.

Patients and Methods

This cross-sectional study was conducted at Health Sciences University, Gaziler Physical Therapy and Rehabilitation Training and Research Hospital, Department of Physical Medicine and Rehabilitation between May 2019 and April 2020. A total of 33 male patients (mean age: 36.6±8.7 years; range, 21 to 48 years) who had LLA due to traumatic injury and were followed in the amputee clinic were included. All patients had completed stump healing. Those with any disease affecting the peripheral nerves (e.g., diabetes mellitus, infections, metabolic problems, inherited causes, and exposure to toxins) were excluded. A written informed consent was obtained from each patient. The study protocol was approved by the Health Sciences University, Gülhane Education and Research Hospital Ethics Committee (May 14, 2019/19-198). The study was conducted in accordance with the principles of the Declaration of Helsinki. Demographic and clinical characteristics of the participants including age, sex, amputation findings (etiology, time since amputation, level, and side), prosthesis use findings (time since prosthesis use, daily use time, type, type of liner, prosthetic foot type), and functional K level of activity after amputation were recorded. The K levels are mostly used to classify the type of ambulation. The level ranges from 0 to 4, where 0 refers to the patient who does not have the ability or potential to ambulate or transfer safely, with or without assistance, and a prosthesis does not enhance their quality of life or mobility, and level 4 has the ability or potential for prosthetic ambulation that exceeds basic ambulation skills, exhibiting high impact, stress, or energy levels. The presence, etiology, and duration of pain were questioned, and the intensity of pain was assessed by Visual Analog Scale (VAS). The Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) was used to evaluate neuropathic pain for the residual limb. The patient’s satisfaction with the current prosthesis was evaluated numerically between 0 (not satisfied at all) and 10 (completely satisfied). All ultrasonographic examinations were performed by a single physiatrist experienced in musculoskeletal sonography. A 5 to 12 MHz linear transducer (Logiq E portable; GE Healthcare, China) was used. To optimize image quality, minimal pressure was applied to the transducer. Each examination was performed bilaterally while the patients were in the prone position. The full course of the SN, TN, and CPN was assessed in a craniocaudal direction starting from the subgluteal fold to the popliteal fossa. The probe was placed axially on the nerves (perpendicular to the nerve) and the CSA was measured at the same level proximal to the bifurcation for the SN (Figure 1), and at a point distal to the bifurcation of the SN for the CPN and TN (Figure 2). The values from the normal sides were accepted as controls. The presence of a neuroma was also evaluated throughout the nerve, particularly at the distal ends. As previously described by Kara et al.,[8] when the mean CSA of the SN was accepted as 43.3±12.5 mm2, the power of the study was calculated as 80% with a type-1 error of 0.05. Accordingly, a total of 34 patients were planned to be recruited. Statistical analysis Statistical analysis was performed using the SPSS for Windows version 16.0 (SPSS Inc., Chicago, IL, USA). Continuous variables were expressed in mean ± standard deviation (SD) or median (min-max). Categorical variables were expressed in number and frequency. The Kolmogorov-Smirnov test was used to confirm that the data showing normal distribution. The Student t-test and Wilcoxon tests were performed to compare SN, CPN and TN CSA values between amputated versus non-amputated sides, K3 versus K4 level activity, microprocessor- controlled knee prosthesis versus other types, and hypobaric sealing membrane versus silicone liners. The Spearman correlation was used to examine the relationship between demographic, clinical, and ultrasound parameters. A p value of <0.05 was considered statistically significant.

Results

Demographic and clinical characteristics of the patients are summarized in Table 1. Sixteen patients reported pain in the amputated extremities. The mean VAS score was 5.0±1.6. Of 16 patients, the most common causes of pain were neuropathic (n=6) and prosthetic use-related pain (n=5). The mean LANSS score for neuropathic pain was 16±4.3. The CSA values were greater on the amputated sides than the non-amputated sides for SN (p=0.001), TN (p=0.001), and CPN (p=0.015), regardless of activity level. Similarly, the amputated side SN (p=0.001), TN (p=0.001), and CPN (p=0.016) were thicker than the non-amputated side in patients with level of K4 activity. There was no significant difference in CSA values between amputated and non-amputated sides in K3 level patients (Table 2). According to the activity level, only the mean values of TN CSA were higher in the amputated side in patients with K3 activity level compared to those at the K4 level (32.5±0.7 vs. 27.3±3.5, respectively) (p=0.035) (Table 3). When the CSA values of the nerves were compared according to types of prosthesis and liner, the amputated side SN was found to be thicker in patients using microprocessor-controlled knee prosthesis (p=0.032) (Table 4). The TN was greater in hypobaric sealing membrane users on the amputated sides (30.0±3.6 vs. 26.5±3.2, respectively) (p=0.041). The correlation analyses for demographic and clinical parameters including age, sex, amputation etiology, time since amputation, level, and side, time since prosthesis use, daily use time, type, type of liner, prosthetic foot type, activity level and ultrasound findings revealed only a negative mild correlation (r=-0.415, p<0.05) with the CSA values of the TN on the amputated sides and daily prosthesis use time.

Discussion

The present study results clearly demonstrated that the CSA of the SN, CPN, and the TN were larger on the amputated sides in all patients. Furthermore, we observed that the SN was found greater in patients using microprocessor-controlled knee prosthesis and TN was greater in hypobaric sealing membrane users on the amputated sides. We also identified a slightly negative correlation between the CSA values of TN on the amputated sides and the duration of daily prosthesis use. Axotomy in peripheral nerves leads to reduced demyelination and atrophy in neurofilaments and eventually loss of motor neurons. After nerve transection, distal axons undergo Wallerian degeneration, while proximal axons undergo functional and morphological changes called axon reaction or retrograde effect.[9] In an animal experiment, permanent axotomy resulted in axonal atrophy in adult cats, but axonal development continued in kittens but never reached to adult size.[10] Kerimoğlu and Canyigit[11] who conducted research on nerve diameter found SN hypertrophy on amputated side not only in the young patient, but also in the adult patient, consistent with the results of Hill et al.[6] in case series involving seven patients with osteosarcoma under the age of 19. There are some animal experiments showing that local application of insulin-like growth factor-I (IGF-I) to the SN stimulates regeneration.[12-14] It was thought that trophic factors such as IGF-I and cytokines secreted by osteosarcoma could be the cause of hypertrophy, but still the etiology has not been fully elucidated, yet. In these two studies, the nerve diameters increased in a direct proportion to the amputation time, and the reason for this increase could be the longer exposure to trophic factors secreted by sarcomas.[6,11] In our study, no significant correlation was found between the amputation time and the CSA values of the nerves. This can be attributed to the fact that all patients were traumatic amputees and not exposed to trophic factors. Peripheral nerve measurements can be helpful in monitoring and preventing problems, such as neuroma that we often see in amputees in rehabilitation clinics. Göktepe et al.[7] examined the thickness and width of the SN nerve in patients with LLA and found that the SN on the amputated side was wider and thicker, and was also thicker in above-knee amputees than in below-knee amputees. They showed that amputation level and duration and presence of neuroma affected the nerve diameter. Therefore, it is thought that the underlying pathogenesis of SN enlargement (proximal) and neuroma formation (distal) may have common determinants However, no neuroma samples were found in our study. In the nervous system, some substances are transported from the center to the periphery and from the periphery to the center. In antegrade transport, all the substances that the axon needs for survival and function are produced in the nerve cell body and transported from the axon to the periphery. These axonal transport substances in neurons include proteins, neurotransmitters, lipids, mitochondria and ribonucleic acid (RNA).[15,16] The function of retrograde transport is the recycling of materials initially transported from the cell body to the axon terminals, as well as the transfer of information to the center by neuro-trophic factors about the axon status, terminals, target cells and general environment.[16,17] Impingement or axotomy in peripheral nerves may affect the circulation of the nerve root and the metabolism of neurotransmitters flowing in the axons by disrupting the axonal flow, resulting in neural edema and, therefore, the amount of endoneural tissue increases and the size of the nerve may eventually grow.[18] In our study, the increase in all CSAs on the amputated side indicates the increase in endoneural tissue as a result of the interruption of axonal transport. Since we believe that the prosthesis and its components may affect the peripheral nerve diameter in amputees, we found it necessary to investigate all these parameters. The prostheses used by amputees have many components. Socket and liner are important parts of prosthesis due to their interfaces between stump and socket.[19-23] Liner is in direct contact with the stump in the socket and plays an important role in transferring the load and distributing the interface pressure over the stump.[24,25] A comfortable liner and socket are important for patients using prosthesis to avoid skin problems in their daily activities.[25,26] Recently, it has been shown that superior quality liners provide better suspension, are more comfortable and cause less dermatological problems than previous prosthetic designs.[27,28] While the silicone liner suspension is based on the shuttle lock system, the hypobaric sealing membrane has five seals around the liner and the socket inner wall that form an airtight seal for proper suspension. Silicone liners adhere to the patient's stump, strengthening the contact surface with the socket and providing a comfortable cushion between the prosthetic socket and the stump. Sadeeq Ali et al.[28] compared the satisfaction level in patients using pelite liner, silicone liner and hypobaric sealing membrane and showed a higher level of satisfaction with silicone liner. A higher level of disappointment, pain, and skin irritation were observed in patients using hypobaric sealing membrane liners. Since the seals in hypobaric sealing membrane liners have the potential to exert additional pressure on the stump, they can be a source of trouble for amputees with sensitive stumps. In another study supporting this concept, it was attempted to measure and evaluate the interface pressure in silicone and hypobaric sealing membrane liners during normal walking. While walking on a flat surface of both liners, the interface pressure in the anterior, posterior, medial and lateral regions was measured. As a result, all pressure measurements of the hypobaric sealing membrane liner were found to be higher than the silicone liner. The silicon liner has been shown to provide greater comfort in the socket than a hypobaric sealing membrane.[20] In our study, a comparison was made between the liner types in terms of the CSA of the nerves. The CSA values of the TN on the amputated side were greater in users of hypobaric sealing membrane compared to silicone liner users. The reasons for this were considered as the seals applying more pressure on the stump and the vacuum effect resulting in more recurrent skin problems and trauma effect in hypobaric sealing membrane liner users. The CSA values of the SN were found to be larger in patients using microprocessor prostheses compared to other prosthesis users. We believe that it is caused by edema formation due to the high burden on the amputated limb, as the microprocessor prostheses are heavier and the patients who use them are more active, this may affect the CSA values. To the best of our knowledge, there is no study on this subject in the literature. Many studies have shown that ultrasonographic measurement is a useful diagnostic tool for evaluating nerve disorders.[6-8,11] Ultrasonography provides clear information about the anatomy and morphology of structures. In this context, it is a guide while revealing the treatment plan or prognosis.[29] For instance, in the presence of an intraneural ganglion cyst requiring surgical procedure, ultrasonography alone detects the etiology that cannot be determined by electrophysiological study, leading to a more accurate prognosis.[30] As a result, peripheral nerve measurements and follow-up of these parameters may contribute to clinicians tracking and selection of the most accurate prosthesis and prosthetic parts. Additionally, peripheral nerve measurements are helpful to analyze and predict lower extremity nerve involvement according to the K activity level. The main limitations of this study are its small sample size and heterogeneous patient distribution according to the K activity levels. However, the main strengths include the evaluation of the prosthesis and liner types clinically, examination of the K activity levels functionally, and scanning of three nerves together sonographically. In conclusion, the SN, the TN, and the CPN were found to be larger in all patients on the amputated sides and in patients with K4 activity level. Based on these findings, the K3 activity level and the use of hypobaric sealing membrane seem to affect the CSA values of the TN. Additionally the use of microprocessor knee prosthesis affects the CSA values of the SN. We consider that these results may be essential for the analysis or prediction of lower extremity nerve involvement according to the K activity level and the use of prosthesis in patients with traumatic LLA.
Table 1

Demographic and clinical characteristics of patients (n=33)

 n%Mean±SDMedianMin-Max
Age (year)  36.6±8.7  
Time since amputation (month)   1325-360
Time since prosthesis use (month)   123.91-360
Daily prosthesis use time (h)   10.61-19
Etiology of amputation     
Mine1545.5   
Hand-made explosive824.2   
Gun515.2   
Rocket26.1   
Traffic accident26.1   
Other13.0   
Side of amputation     
Right1648.5   
Left1751.5   
Level of amputation     
Above knee720.6   
Knee disarticulation38.8   
Below knee2058.8   
Chopart411.8   
Type of prosthesis     
Microprocessor-controlled knee prosthesis927.3   
Hydrolic knee prosthesis13.0   
Active vacuum system modular below-knee prosthesis1854.5   
Passive vacuum system modular below-knee prosthesis 13.0   
Chopart prosthesis412.1   
Type of liner     
Hypobaric sealing membrane1854.5   
Silicone liner1133.3   
Prosthetic Foot     
Carbon2163.6   
Hydrolic824.2   
Chopart412.1   
Satisfaction with prosthesis  7.0±2.8  
Activity level     
K339.1   
K43090.9   
SD: Standard deviation.
Table 2

Comparisons of the CSA values of nerves on amputated and non-amputated sides

 All patientsK3 levelK4 level
Non-amputated sideAmputated sidepNon-amputated sideAmputated sidepNon-amputated sideAmputated sidep
Mean±SDMean±SDMean±SDMean±SDMean±SDMean±SD
Sciatic nerve (mm2)49.5±7.153.1±7.00.00153.3±3.158.3±1.20.10949.2±7.452.6±7.20.001
Common peroneal nerve (mm2)17.5±3.518.6±3.50.01517.6±2.116.5±0.71.017.5±3.618.8±3.70.016
Tibial nerve (mm2)25.8±3.927.6±3.60.00128.6±1.532.5±0.70.18025.5±4.027.3±3.50.001
CSA: cross-sectional area; SD: Standard deviation; Wilcoxon test was used.
Table 3

Comparisons of CSA values of the nerves according to K activity level

 Non-amputated side Amputated side 
 K3K4 K3K4 
NervesMean±SDMean±SDpMean±SDMean±SDp
Sciatic nerve (mm2)53.3±3.149.2±7.40.25858.3±1.252.6±7.20.132
Common peroneal nerve (mm2)17.6±2.117.5±3.60.92516.5±0.718.8±3.70.324
Tibial nerve (mm2)28.6±1.525.5±4.00.11632.5±0.727.3±3.50.035
CSA: cross-sectional area; SD: Standard deviation; Student t-test was used.
Table 4

Comparison of CSA values of the nerves between patients using microprocessor-controlled knee prosthesis and other prostheses

NervesNon-amputated sidepAmputated sidep
Micropressor-controlledOtherMicropressor-controlledOther
Mean±SDMean±SDMean±SDMean±SD
Sciatic nerve (mm2)51.8±5.248.6±7.60.24057.2±5.551.6±7.00.032
Common peroneal nerve (mm2)17.4±2.817.5±3.70.98419.2±3.218.6±3.70.630
Tibial nerve (mm2)27.1±3.725.3±3.90.23930.4±4.027.1±3.30.124
CSA: cross-sectional area; SD: Standard deviation; Student t-test was used.
  28 in total

1.  Effects of liner stiffness for trans-tibial prosthesis: a finite element contact model.

Authors:  Chih-Chieh Lin; Chih-Han Chang; Chu-Lung Wu; Kao-Chi Chung; I-Chen Liao
Journal:  Med Eng Phys       Date:  2004-01       Impact factor: 2.242

2.  Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects.

Authors:  Xiaohong Jia; Ming Zhang; Winson C C Lee
Journal:  J Biomech       Date:  2004-09       Impact factor: 2.712

3.  Effect of lumbar nerve root compression on primary sensory neurons and their central branches: changes in the nociceptive neuropeptides substance P and somatostatin.

Authors:  Shigeru Kobayashi; Yasuo Kokubo; Kenzo Uchida; Takafumi Yayama; Kenichi Takeno; Kouhei Negoro; Hideaki Nakajima; Hisatoshi Baba; Hidezo Yoshizawa
Journal:  Spine (Phila Pa 1976)       Date:  2005-02-01       Impact factor: 3.468

Review 4.  Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses.

Authors:  E C T Baars; J H B Geertzen
Journal:  Prosthet Orthot Int       Date:  2005-04       Impact factor: 1.895

5.  Sonographic evaluation of sciatic nerves in patients with unilateral sciatica.

Authors:  Murat Kara; Levent Özçakar; Tülay Tiftik; Bayram Kaymak; Sumru Özel; Selami Akkuş; Ayşen Akinci
Journal:  Arch Phys Med Rehabil       Date:  2012-03-24       Impact factor: 3.966

6.  Quantification of prosthetic outcomes: elastomeric gel liner with locking pin suspension versus polyethylene foam liner with neoprene sleeve suspension.

Authors:  Kim L Coleman; David A Boone; Linda S Laing; David E Mathews; Douglas G Smith
Journal:  J Rehabil Res Dev       Date:  2004-07

7.  Cardiometabolic risk parameters of individuals with lower extremity amputation: What is the effect of adherence to DASH diet and Mediterranean diet?

Authors:  Özlem Köroğlu; Kübra Tel Adıgüzel
Journal:  Turk J Phys Med Rehabil       Date:  2020-08-17

8.  Paradoxic hypertrophy of the sciatic nerve in adult patients after above-knee amputation.

Authors:  U Kerimoglu; M Canyigit
Journal:  Acta Radiol       Date:  2007-11       Impact factor: 1.990

9.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

Review 10.  Nerve growth factor: from the early discoveries to the potential clinical use.

Authors:  Luigi Aloe; Maria Luisa Rocco; Patrizia Bianchi; Luigi Manni
Journal:  J Transl Med       Date:  2012-11-29       Impact factor: 5.531

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.