Literature DB >> 16180375

Literature review of the possible advantages of silicon liner socket use in trans-tibial prostheses.

E C T Baars1, J H B Geertzen.   

Abstract

The silicon liner socket has been used in the trans-tibial prosthesis since the 1980s. Silicon liner sockets are sleeves of silicon material that are rolled onto the stump and fix the prosthesis to it. The producers of the liners propagate many advantages in their use i.e. better suspension of the prosthesis, protection of the stump skin and improved cosmetic appearance. This review was performed to find objective documentation in the literature in support of the advantages in prosthetic fitting and use of silicon liners. A medline search was performed with the key words: "silicon liner socket, Icelandic Roll On Silicon Socket (ICEROSS), trans-tibial prosthesis, lower leg prosthesis and stump sockets". Six articles remained after application of the selection criteria. In two studies clinical examination was done while in the rest questionnaires were used to collect data. The indication for amputation varied from vascular insufficiency, diabetes mellitus and infection to trauma. Most studies mentioned improved prosthetic suspension compared to the conventional supracondylar fitting. Also the walking performance improved with less use of walking aids. There were reports of positive but also negative effects on the skin such as excessive perspiration and itching. Patients had a general preference in prosthetic appearance in favour of the prosthesis with a silicon liner. Further research is needed with the use of objective clinical parameters and a homogenous study group objectively to find advantages in the use of the silicon liner socket in the trans-tibial prosthesis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16180375     DOI: 10.1080/17461550500069612

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  14 in total

1.  A digital patient for computer-aided prosthesis design.

Authors:  Giorgio Colombo; Giancarlo Facoetti; Caterina Rizzi
Journal:  Interface Focus       Date:  2013-04-06       Impact factor: 3.906

2.  Elastomeric liners for people with transtibial amputation: Survey of prosthetists' clinical practices.

Authors:  Brian J Hafner; John C Cagle; Katheryn J Allyn; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2016-09-24       Impact factor: 1.895

3.  Evaluating the use of a thermoplastic socket in Kenya: A pilot study.

Authors:  Giulia Barbareschi; Wesley Teerlink; Josepg Gakunga Njuguna; Purity Musungu; Mary Dama Kirino; Catherine Holloway
Journal:  Prosthet Orthot Int       Date:  2022-03-25       Impact factor: 1.672

4.  Evaluation of new suspension system for limb prosthetics.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali; Nooranida Arifin; Wan Abu Bakar Wan Abas
Journal:  Biomed Eng Online       Date:  2014-01-10       Impact factor: 2.819

5.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

6.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

7.  The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Sadeeq Ali
Journal:  PLoS One       Date:  2014-05-14       Impact factor: 3.240

8.  Development of an air pneumatic suspension system for transtibial prostheses.

Authors:  Gholamhossein Pirouzi; Noor Azuan Abu Osman; Azim Ataollahi Oshkour; Sadeeq Ali; Hossein Gholizadeh; Wan A B Wan Abas
Journal:  Sensors (Basel)       Date:  2014-09-09       Impact factor: 3.576

Review 9.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

10.  The modular socket system in a rural setting in Indonesia.

Authors:  Bob Giesberts; Liezel Ennion; Olle Hjelmstrom; Agusni Karma; Knut Lechler; Edsko Hekman; Arjen Bergsma
Journal:  Prosthet Orthot Int       Date:  2017-11-20       Impact factor: 1.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.