Effects of liner stiffness for trans-tibial prosthesis: a finite element contact model.

Chih-Chieh Lin1, Chih-Han Chang, Chu-Lung Wu, Kao-Chi Chung, I-Chen Liao.   

Abstract

The socket liner plays a crucial role in redistribution of the interface stresses between the stump and the socket, so that the peak interface stress could be reduced. However, how the peak stress is affected by various liner stiffnesses is still unknown, especially when the phenomenon of the stump slide within the socket is considered. This study employed nonlinear contact finite element analyses to study the biomechanical reaction of the stump sliding with particular attention to the liner stiffness effects of the trans-tibial prosthesis. To validate the finite element outcomes, experimental measurements of the interface stresses and sliding distance were further executed. The results showed that the biomechanical response of the stump sliding are highly nonlinear. With a less stiff liner, the slide distance of the stump would increase with a larger contact area. However, this increase in the contact area would not ensure a reduction in the peak interface stress and this is due to the combined effects of the non-uniform shape of the socket and the various sliding distances generated by the different liner stiffnesses.

Mesh:

Substances:

Year:  2004        PMID: 14644593     DOI: 10.1016/s1350-4533(03)00127-9

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

2.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

3.  Comparative study between Dermo, Pelite, and Seal-In X5 liners: effect on patient's satisfaction and perceived problems.

Authors:  Sadeeq Ali; Noor Azuan Abu Osman; Nooranida Arifin; Hossein Gholizadeh; Nasrul Anwar Abd Razak; Wan Abu Bakar Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-11

4.  Assessment of lower limb peripheral nerves with ultrasound in patients with traumatic amputation.

Authors:  İlkay Karabay; Yasin Demir; Özlem Köroğlu; Sefa Gümrük Aslan; Koray Aydemir; Eda Gürçay
Journal:  Turk J Phys Med Rehabil       Date:  2021-09-01

Review 5.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13