Literature DB >> 2788088

A unified computer program for assessment of attenuation correction and data acquisition methods in single photon emission computed tomography (SPECT).

K Murase1, S Tanada, H Higashino, M Yamada, M Miyagawa, A Iio, K Hamamoto.   

Abstract

A computer based simulation program was developed to assess the usefulness of various attenuation correction algorithms and data acquisition methods in single photon emission computed tomography (SPECT) in a unified approach. The program analytically calculated projection ray sums from a mathematical model with various distributions of activities and either uniform or non uniform attenuation coefficients by using the line integrals including the effect of attenuation. Data acquisition starting at arbitrary angles, various acquisition angles, including a 180 degree scan and a non circular orbit of a gamma camera, including an elliptical orbit can readily be taken into consideration in our simulation program. To simulate non circular orbit data acquisition, the resolution dependence on the object distance from the collimator surface was incorporated into the simulation. This computer based simulation program allows various combinations of attenuation correction algorithms such as hybrid methods, and data acquisition methods can be evaluated under a large number of study conditions. The usefulness of this computer based simulation program is shown with several representative examples.

Mesh:

Year:  1989        PMID: 2788088     DOI: 10.1007/bf00257542

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; D R Gilland; J R Perry; W H McCartney
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

2.  SPECT using a specially designed cone beam collimator.

Authors:  R J Jaszczak; K L Greer; R E Coleman
Journal:  J Nucl Med       Date:  1988-08       Impact factor: 10.057

3.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

4.  A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT).

Authors:  K Murase; H Itoh; H Mogami; M Ishine; M Kawamura; A Iio; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1987

5.  Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging.

Authors:  R L Eisner; D J Nowak; R Pettigrew; W Fajman
Journal:  J Nucl Med       Date:  1986-11       Impact factor: 10.057

6.  "Circumferential profiles:" a new method for computer analysis of thallium-201 myocardial perfusion images.

Authors:  R D Burow; M Pond; A W Schafer; L Becker
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

7.  Convolutional image reconstruction for quantitative single photon emission computed tomography.

Authors:  E Tanaka; H Toyama; H Murayama
Journal:  Phys Med Biol       Date:  1984-12       Impact factor: 3.609

8.  SPECT resolution and uniformity improvements by noncircular orbit.

Authors:  S C Gottschalk; D Salem; C B Lim; R H Wake
Journal:  J Nucl Med       Date:  1983-09       Impact factor: 10.057

9.  Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera.

Authors:  N Tamaki; T Mukai; Y Ishii; Y Yonekura; K Yamamoto; K Kadota; H Kambara; C Kawai; K Torizuka
Journal:  Radiology       Date:  1983-05       Impact factor: 11.105

10.  Attenuation correction in gamma emission computed tomography.

Authors:  T E Walters; W Simon; D A Chesler; J A Correia
Journal:  J Comput Assist Tomogr       Date:  1981-02       Impact factor: 1.826

View more
  1 in total

1.  Methods for measuring the renal uptake rate of 99mTc-dimercaptosuccinic acid (DMSA): a comparative study.

Authors:  K Murase; S Tanada; M Ishine; M Yokoyama; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1990
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.