Literature DB >> 1764341

Performance of a multislice fan beam collimator for SPECT imaging of the head.

Y Akiyama1, N Yui.   

Abstract

A multislice fan beam collimator was designed for a SPECT system with a rotating scintillation camera, and it was constructed by the lead casting method which was devised in recent years. The focal length from the surface of the detector side of the collimator is 75 cm. In order to reconstruct the SPECT images we modified the interpolation method which was developed for reconstruction of the X-ray CT and applied it. Primary photopeak data were obtained with a 20% energy window centered at 140 keV for 99mTc and 159 keV for 123I. The fan beam collimator reduces the field of view, and it would therefore be limited to use only for the head and neck region at present; however, both resolution and sensitivity were approximately 20% better than those of the parallel hole collimator. A fan beam collimator is a useful implement for the SPECT study.

Mesh:

Year:  1991        PMID: 1764341     DOI: 10.1007/bf03164624

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  11 in total

1.  Whole-body single-photon emission computed tomography using dual, large-field-of-view scintillation cameras.

Authors:  R J Jaszczak; L T Chang; N A Stein; F E Moore
Journal:  Phys Med Biol       Date:  1979-11       Impact factor: 3.609

2.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; D R Gilland; J R Perry; W H McCartney
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

3.  Principles of scintillation camera image magnification with multichannel convergent collimators.

Authors:  J E Dowdey; F J Bonte
Journal:  Radiology       Date:  1972-07       Impact factor: 11.105

4.  Use of magnifying multihole colimators in the gamma-ray camera system.

Authors:  S Rudin; P A Bardfeld; H Hart
Journal:  J Nucl Med       Date:  1971-12       Impact factor: 10.057

5.  [SPECT images using a multislice fan beam collimator].

Authors:  Y Akiyama; S Sakata; N Yui
Journal:  Radioisotopes       Date:  1986-10

6.  SPECT resolution and uniformity improvements by noncircular orbit.

Authors:  S C Gottschalk; D Salem; C B Lim; R H Wake
Journal:  J Nucl Med       Date:  1983-09       Impact factor: 10.057

7.  Oblique-angle tomography: a restructuring algorithm for transaxial tomographic data.

Authors:  J A Borrello; N H Clinthorne; W L Rogers; J H Thrall; J W Keyes
Journal:  J Nucl Med       Date:  1981-05       Impact factor: 10.057

8.  Physical attributes of single-photon tomography.

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1980-06       Impact factor: 10.057

9.  A comparison of brain imaging with gamma camera, single-photon emission computed tomography, and transmission computed tomography: concise communication.

Authors:  N E Watson; R J Cowan; M R Ball; D M Moody; D W Laster; C D Maynard
Journal:  J Nucl Med       Date:  1980-06       Impact factor: 10.057

10.  [Single photon radioisotope emission computed tomography image using gamma camera (author's transl)].

Authors:  Y Akiyama; F Kinoshita; M Koakutsu; S Sakata; N Yui
Journal:  Radioisotopes       Date:  1979-08
View more
  1 in total

1.  Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT.

Authors:  Franziska Mathies; Ivayla Apostolova; Lena Dierck; Janin Jacobi; Katja Kuen; Markus Sauer; Michael Schenk; Susanne Klutmann; Attila Forgács; Ralph Buchert
Journal:  EJNMMI Res       Date:  2022-08-17       Impact factor: 3.434

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.