Literature DB >> 34849679

Impact of ascending aortic prosthetic grafts on early postoperative descending aortic biomechanics on cardiac magnetic resonance imaging.

Maria C Palumbo1,2, Alberto Redaelli2, Matthew Wingo1, Katherine A Tak3, Jeremy R Leonard1, Jiwon Kim3, Lisa Q Rong4, Christine Park3, Hannah W Mitlak3, Richard B Devereux3, Mary J Roman3, Arindam RoyChoudury5, Christopher Lau1, Mario F L Gaudino1, Leonard N Girardi1, Jonathan W Weinsaft3.   

Abstract

OBJECTIVES: Among patients with ascending thoracic aortic aneurysms, prosthetic graft replacement yields major benefits but risk for recurrent aortic events persists for which mechanism is poorly understood. This pilot study employed cardiac magnetic resonance to test the impact of proximal prosthetic grafts on downstream aortic flow and vascular biomechanics.
METHODS: Cardiac magnetic resonance imaging was prospectively performed in patients with thoracic aortic aneurysms undergoing surgical (Dacron) prosthetic graft implantation. Imaging included time resolved (4-dimensional) phase velocity encoded cardiac magnetic resonance for flow quantification and cine-cardiac magnetic resonance for aortic wall distensibility/strain.
RESULTS: Twenty-nine patients with thoracic aortic aneurysms undergoing proximal aortic graft replacement were studied; cardiac magnetic resonance was performed pre- [12 (4, 21) days] and postoperatively [6.4 (6.2, 7.2) months]. Postoperatively, flow velocity and wall shear stress increased in the arch and descending aorta (P < 0.05); increases were greatest in hereditary aneurysm patients. Global circumferential strain correlated with wall shear stress (r = 0.60-0.72, P < 0.001); strain increased postoperatively in the native descending and thoraco-abdominal aorta (P < 0.001). Graft-induced changes in biomechanical properties of the distal native ascending aorta were associated with post-surgical changes in descending aortic wall shear stress, as evidenced by correlations (r = -0.39-0.52; P ≤ 0.05) between graft-induced reduction of ascending aortic distensibility and increased distal native aortic wall shear stress following grafting.
CONCLUSIONS: Prosthetic graft replacement of the ascending aorta increases downstream aortic wall shear stress and strain. Postoperative increments in descending aortic wall shear stress correlate with reduced ascending aortic distensibility, suggesting that grafts provide a nidus for high energy flow and adverse distal aortic remodelling.
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic remodelling; Prosthetic graft; Thoracic aortic aneurysm

Mesh:

Year:  2022        PMID: 34849679      PMCID: PMC8947796          DOI: 10.1093/ejcts/ezab501

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  20 in total

1.  In vitro investigation of a novel elastic vascular prosthesis for valve-sparing aortic root and ascending aorta replacement.

Authors:  Michael Scharfschwerdt; Moritz Leonhard; Judith Lehmann; Doreen Richardt; Helmut Goldmann; Hans-Hinrich Sievers
Journal:  Eur J Cardiothorac Surg       Date:  2015-11-24       Impact factor: 4.191

2.  Prosthetic replacement of the ascending aorta increases wall tension in the residual aorta.

Authors:  Michael Scharfschwerdt; Hans-H Sievers; Johanna Greggersen; Thorsten Hanke; Martin Misfeld
Journal:  Ann Thorac Surg       Date:  2007-03       Impact factor: 4.330

3.  Impact of aortic grafts on arterial pressure: a computational fluid dynamics study.

Authors:  O Vardoulis; E Coppens; B Martin; P Reymond; P Tozzi; N Stergiopulos
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-09-01       Impact factor: 7.069

4.  Immediate Impact of Prosthetic Graft Replacement of the Ascending Aorta on Circumferential Strain in the Descending Aorta.

Authors:  Lisa Q Rong; Maria C Palumbo; Mohamed Rahouma; Massimiliano Meineri; Gabriel R Arguelles; Jiwon Kim; Christopher Lau; Richard B Devereux; Kane O Pryor; Leonard N Girardi; Alberto Redaelli; Mario F L Gaudino; Jonathan W Weinsaft
Journal:  Eur J Vasc Endovasc Surg       Date:  2019-08-21       Impact factor: 7.069

5.  Aortic flow after valve sparing root replacement with or without neosinuses reconstruction.

Authors:  Mario Gaudino; Filippo Piatti; Christopher Lau; Francesco Sturla; Jonathan W Weinsaft; Luca Weltert; Emiliano Votta; Nicola Galea; Ilaria Chirichilli; Antonino Di Franco; Marco Francone; Carlo Catalano; Alberto Redaelli; Leonard N Girardi; Ruggero De Paulis
Journal:  J Thorac Cardiovasc Surg       Date:  2018-07-27       Impact factor: 5.209

6.  Descending aortic strain quantification by intra-operative transesophageal echocardiography: Multimodality validation via cardiovascular magnetic resonance.

Authors:  Lisa Q Rong; Maria C Palumbo; Mohammed Rahouma; Alexandra J Lopes; Richard B Devereux; Jiwon Kim; Leonard N Girardi; Mario Gaudino; Jonathan W Weinsaft
Journal:  Echocardiography       Date:  2020-09-10       Impact factor: 1.724

7.  Decreased biventricular function following thoracic endovascular aortic repair.

Authors:  Maximilian Kreibich; Julia Morlock; Friedhelm Beyersdorf; Tim Berger; Stephan Allweier; Stoyan Kondov; Clarence Pingpoh; Martin Czerny; Matthias Siepe; Bartosz Rylski
Journal:  Interact Cardiovasc Thorac Surg       Date:  2020-04-01

8.  Associations of Age and Sex With Marfan Phenotype: The National Heart, Lung, and Blood Institute GenTAC (Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions) Registry.

Authors:  Mary J Roman; Richard B Devereux; Liliana R Preiss; Federico M Asch; Kim A Eagle; Kathryn W Holmes; Scott A LeMaire; Cheryl L Maslen; Dianna M Milewicz; Shaine A Morris; Siddharth K Prakash; Reed E Pyeritz; William J Ravekes; Ralph V Shohet; Howard K Song; Jonathan W Weinsaft
Journal:  Circ Cardiovasc Genet       Date:  2017-06

9.  Rationale and design of the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC).

Authors:  Kim A Eagle
Journal:  Am Heart J       Date:  2008-12-17       Impact factor: 4.749

10.  Aortic stiffness and diameter predict progressive aortic dilatation in patients with Marfan syndrome.

Authors:  Gijs J Nollen; Maarten Groenink; Jan G P Tijssen; Ernst E Van Der Wall; Barbara J M Mulder
Journal:  Eur Heart J       Date:  2004-07       Impact factor: 29.983

View more