Literature DB >> 31848600

Decreased biventricular function following thoracic endovascular aortic repair.

Maximilian Kreibich1, Julia Morlock1, Friedhelm Beyersdorf1, Tim Berger1, Stephan Allweier1, Stoyan Kondov1, Clarence Pingpoh1, Martin Czerny1, Matthias Siepe1, Bartosz Rylski1.   

Abstract

OBJECTIVES: Preclinical studies have suggested acute stiffening of the aorta following experimental thoracic endovascular aortic repair (TEVAR), resulting in acute elevated pulse pressure, hypertension and possibly heart failure. The aim of this study was to evaluate cardiac remodelling following TEVAR.
METHODS: From 2005 to 2018, 519 TEVAR procedures were performed at a single centre. Transthoracic echocardiography was performed pre- and post-TEVAR in 31 patients without previous replacement of the thoracic aorta. Patient characteristics, drug information, radiographic and follow-up data were evaluated. Aortic details were measured in multiplanar reconstruction.
RESULTS: Transthoracic echocardiography was performed 2 ± 2 years after TEVAR. At this time, patients received significantly more antihypertensive drugs compared to the pre-TEVAR intake (beta-blocker therapy: P = 0.037; calcium channel blocker: P = 0.022). Compared to pre-TEVAR, there was a significant reduction in the left ventricular ejection fraction (P = 0.008) and tricuspid annular plane systolic excursion (P = 0.013) post-TEVAR. A significant increase in the left ventricular mass was not detected in this study (P = 0.95). The mean distance of 163 ± 66 mm of the descending aorta was covered.
CONCLUSIONS: This study suggests negative cardiac remodelling with a decrease in the left and right ventricular function following TEVAR despite an increase in oral antihypertensive medication. The impact of stiffer endovascular grafts compared with the native aortic wall should be considered by endovascular specialists and manufacturers.
© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aorta; Cardiac function; Cardiac remodelling; Thoracic endovascular aortic repair

Mesh:

Year:  2020        PMID: 31848600     DOI: 10.1093/icvts/ivz298

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  3 in total

1.  Impact of ascending aortic prosthetic grafts on early postoperative descending aortic biomechanics on cardiac magnetic resonance imaging.

Authors:  Maria C Palumbo; Alberto Redaelli; Matthew Wingo; Katherine A Tak; Jeremy R Leonard; Jiwon Kim; Lisa Q Rong; Christine Park; Hannah W Mitlak; Richard B Devereux; Mary J Roman; Arindam RoyChoudury; Christopher Lau; Mario F L Gaudino; Leonard N Girardi; Jonathan W Weinsaft
Journal:  Eur J Cardiothorac Surg       Date:  2022-03-24       Impact factor: 4.191

2.  The effect of aortic arch replacement on pulse wave velocity after surgery.

Authors:  Daijiro Hori; Sho Kusadokoro; Makiko Naka Mieno; Tomonari Fujimori; Toshikazu Shimizu; Naoyuki Kimura; Atsushi Yamaguchi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-03-31

3.  The 3-step approach for the treatment of multisegmental thoraco-abdominal aortic pathologies.

Authors:  Tim Berger; Maximilian Kreibich; Bartosz Rylski; Stoyan Kondov; Albi Fagu; Friedhelm Beyersdorf; Matthias Siepe; Martin Czerny
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-07-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.