| Literature DB >> 34841462 |
Ola Belfrage1, Erik Weber2, Martin Sundberg2, Gunnar Flivik2.
Abstract
INTRODUCTION: Previous bone density studies have generally shown bone resorption around both cemented and uncemented total hip arthroplasty (THA) stems. This is presumed to be due to stress shielding. Short stems have been introduced partly to preserve bone in the proximal femur by a more physiological loading of the bone. The purpose of this study was to evaluate bone remodeling around a short, fully hydroxyapatite-coated titanium stem that comes in a collared and collarless version. PATIENTS AND METHODS: A prospective cohort of 50 patients included in a study evaluating the Furlong Evolution stem has been followed for 5 years. Examination was done with dual energy X-ray absorptiometry (DXA) postoperatively, at 1, 2 and 5 years. Clinical outcome was followed with radiography and both general and hip specific outcome measures.Entities:
Keywords: Bone density; DXA; Short stem THA; THA
Mesh:
Substances:
Year: 2021 PMID: 34841462 PMCID: PMC9522768 DOI: 10.1007/s00402-021-04225-z
Source DB: PubMed Journal: Arch Orthop Trauma Surg ISSN: 0936-8051 Impact factor: 2.928
Fig. 1Stem design in lateral view, the collared and the collarless version with 133-degree neck shaft angle
Patient baseline characteristics
| Variables | Collar | Collarless | Total |
|---|---|---|---|
| No. of patients | 25 | 25 | 50 |
| Age (range) | 58.5 (36–75) | 60.2 (43–75) | 59.8 (36–75) |
| Gender (M = male; F = female) | 16 M; 9F | 18 M; 7F | 34 M; 16F |
| BMI (SD) | 26.7 (3.2) | 26.6 (3.3) | 26.6 (3.2) |
Fig. 2CONSORT flow diagram
Precision error of DXA measurement analyses in the seven Gruen zones expressed as the coefficient of variation in percentage, obtained from 49 double examinations [10]
| Gruen zones | Precision error (% CV) |
|---|---|
| 1 | 0.34 |
| 2 | 0.66 |
| 3 | 0.79 |
| 4 | 0.32 |
| 5 | 0.78 |
| 6 | 0.79 |
| 7 | 0.99 |
Change in bone mineral density (BMD) in the seven Gruen zones and combined net value. Numbers are % difference in mean versus post-operative examination with 95% confidence interval
| Gruen zone | Comparison vs. baseline | Change in BMD | 95% CI |
|---|---|---|---|
| Zone 1 | 1 year | − 1.5 | − 6.4 to 3.4 |
| 2 year | 5.4 | 0.8 to 10.0 | |
| 5 year | 3.9 | 0.1 to 7.7 | |
| Zone 2 | 1 year | − 10.1 | − 14.0 to − 6.2 |
| 2 year | − 1.8 | − 5.5 to 1.8 | |
| 5 year | − 5.3 | − 8.4 to − 2.2 | |
| Zone 3 | 1 year | 1.2 | − 1.3 to 3.7 |
| 2 year | 7.3 | 5.0 to 9.5 | |
| 5 year | 7.8 | 6.0 to 9.7 | |
| Zone 4 | 1 year | − 2.9 | − 4.4 to − 1.5 |
| 2 year | 0.8 | − 0.6 to 2.2 | |
| 5 year | 1.2 | 0.1 to 2.3 | |
| Zone 5 | 1 year | 2.0 | 0.0 to 4.0 |
| 2 year | 8.7 | 6.9 to 10.6 | |
| 5 year | 9.1 | 7.6 to 10.6 | |
| Zone 6 | 1 year | − 9.2 | − 11.6 to − 6.7 |
| 2 year | − 6.0 | − 8.4 to − 3.5 | |
| 5 year | − 8.7 | − 11.3 to − 6.1 | |
| Zone 7 | 1 year | − 15.2 | − 19.2 to − 11.2 |
| 2 year | − 10.4 | − 14.4 to − 6.4 | |
| 5 year | − 15.9 | − 20.3 to − 11.6 | |
| Net BMD | 1 year | − 2.9 | − 4.4 to − 1.5 |
| 2 year | 2.3 | 0.8 to 3.7 | |
| 5 year | 1.2 | − 0.4 to 2.8 |
Fig. 3Net BMD vs. time
Fig. 4Radiograph demonstrating the seven Gruen zones. Graphs represent the change in BMD in percentage (y-axis) over time in years (x-axis). Blue = collarless; red = collared