| Literature DB >> 34642159 |
Tom Biersteker1, Alexander Hilt1, Enno van der Velde1, Martin Jan Schalij1, Roderick Willem Treskes1.
Abstract
BACKGROUND: Mobile health (mHealth) is an emerging field of scientific interest worldwide. Potential benefits include increased patient engagement, improved clinical outcomes, and reduced health care costs. However, mHealth is often studied in projects or trials, and structural implantation in clinical practice is less common.Entities:
Keywords: cardiology; eHealth; mHealth; mobile phone; patient empowerment; patient satisfaction; remote patient monitoring
Year: 2021 PMID: 34642159 PMCID: PMC8726018 DOI: 10.2196/26072
Source DB: PubMed Journal: JMIR Cardio ISSN: 2561-1011
Figure 1Protocols for follow-up with the Box. AF: atrial fibrillation; GP: general practitioner.
Figure 2The Box with all mobile health devices.
The measuring frequency and devices provided per patient group (N=1140).
| Devices | Measuring frequency and follow-up duration | |||||
|
| Myocardial infarction (n=449); thrice per week; 12-month follow-up | Cardiac surgery (n=290); thrice per weeka; 3-month follow-up | Atrial fibrillation (n=260); once per week; 12-month follow-up | Device patients (n=71); thrice per week; follow-up differs per user | Heart failure (n=65); thrice per week; indefinite follow-up | Grown-ups with congenital heart (n=29); twice per week; indefinite follow-up |
| Blood pressure monitor | ✓b | ✓ | ✓ | ✓ | ✓ | ✓ |
| Weight scale | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Pedometer | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Thermometer |
| ✓ |
|
|
|
|
| AliveCor Kardia | ✓ | ✓ |
| ✓ | ✓ | ✓ |
| CardioSecurc |
| ✓ | ✓ |
|
|
|
| Pulse oximeter |
| ✓ |
|
|
|
|
aDaily measurements during the first 2 weeks after discharge.
bDevice used.
cCardioSecur measurements: once every week, plus an extra registration when there are complaints of palpitations, or when the AliveCor Kardia detects possible atrial fibrillation.
Group characteristics of Box patients (N=1140).
| Group characteristics | Total (n=1140) | Myocardial infarction (n=449) | Cardiac surgery (n=290) | Atrial fibrillation (n=260) | Device patients (n=71) | Heart failure (n=65) | Grown-ups with congenital heart (n=29) |
| Sex (male), n (%) | 839 (73.6) | 336 (75.5) | 221 (76.2) | 185 (71.2) | 55 (77.5) | 40 (60.1) | 16 (55.2) |
| Age (years), median (IQR; range) | 60.8 (52.9-69.3; 21.2-83.0) | 59.9 (52.0-67.8; 32.7-83.0) | 61.2 (53.9-69.5; 21.6-80.9) | 62.0 (56.9-69.5; 34.8-78.9) | 66.3 (59.7-72.6; 44.3-79.1) | 67.4 (52.2-72.9; 32.8-80.0) | 46.4 (43.9-49.6; 21.2-57.7) |
| Number of measurements, median (IQR; range) | 260 (105-641; 1-3159) | 336 (133-790; 2-3159) | 295 (159-504; 2-2537) | 54 (16-128; 2-993) | 867 (503-1177; 1-2010) | 337 (145-492; 6-1882) | 169 (62-368; 11-1675) |
| Number of days of measurements taken, median (IQR; range) | 189 (98-372; 1-1216) | 296 (120-466; 1-1216) | 165 (87-338; 1-846) | 137 (43-232; 1-519) | 303 (230-376; 1-468) | 142 (99-177; 3-246) | 144 (104-179; 2-230) |
| Travel distance (kilometers), median (IQR; range) | 14.8 (7.0-24.3; 1.0-2075.0) | 10.5 (5.1-21.2; 1.0-571.0) | 14.8 (7.0-23.0; 1.0-2075.0) | 16.6 (10.1-28.7; 1.0-193.6) | 17.3 (7.0-28.0; 3.1-121.1) | 14.3 (7.0-20.9; 2.6-105.8) | 50.1 (22.9-119.6; 5.1-230.9) |
Figure 3The cumulative number of Box patients over time. The Box: randomized controlled trial randomizing 200 patients after myocardial infarction to either the Box or regular follow-up. The Box 2.0: trial including 350 post–cardiac surgery patients comparing them with 350 historic control patients. Device patients: patients with an implantable cardioverter-defibrillator or cardiac resynchronization therapy device (patients with AF: patients who underwent atrial fibrillation ablation). AF: atrial fibrillation; GUCH: grown-ups with congenital heart; HF: heart failure.
Figure 4Patient spread throughout the Netherlands and Europe. The red dots represent patient locations, and the green dot represents the location of the Leiden University Medical Center.
Figure 5The user interface of the electronic medical record as of 2020, with incorporation of device and electrocardiogram data from the Withings Move electrocardiogram. ECG: electrocardiogram.