Literature DB >> 25650582

PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging.

Stefaan Vandenberghe1, Paul K Marsden.   

Abstract

The integration of positron emission tomography (PET) and magnetic resonance imaging (MRI) has been an ongoing research topic for the last 20 years. This paper gives an overview of the different developments and the technical problems associated with combining PET and MRI in one system. After explaining the different detector concepts for integrating PET-MRI and minimising interference the limitations and advantages of different solutions for the detector and system are described for preclinical and clinical imaging systems. The different integrated PET-MRI systems are described in detail. Besides detector concepts and system integration the challenges and proposed solutions for attenuation correction and the potential for motion correction and resolution recovery are also discussed in this topical review.

Mesh:

Year:  2015        PMID: 25650582     DOI: 10.1088/0031-9155/60/4/R115

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  48 in total

1.  Sensitivity estimation in time-of-flight list-mode positron emission tomography.

Authors:  J L Herraiz; A Sitek
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

2.  Innovative Physics and Engineering Research in Nuclear Medicine and Molecular Imaging: A Message from the Associate Editor.

Authors:  Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2015-10-26

3.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

Review 4.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

5.  Modularized compact positron emission tomography detector for rapid system development.

Authors:  Daoming Xi; Xiang Liu; Chen Zeng; Wei Liu; Yanzhao Li; Yuexuan Hua; Xiongze Mei; Heejong Kim; Peng Xiao; Chien-Min Kao; Qingguo Xie
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-20

Review 6.  From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies.

Authors:  Zhaolin Chen; Sharna D Jamadar; Shenpeng Li; Francesco Sforazzini; Jakub Baran; Nicholas Ferris; Nadim Jon Shah; Gary F Egan
Journal:  Hum Brain Mapp       Date:  2018-08-04       Impact factor: 5.038

7.  A novel alternative to classify tissues from T 1 and T 2 relaxation times for prostate MRI.

Authors:  Jorge Zavala Bojorquez; Stéphanie Bricq; François Brunotte; Paul M Walker; Alain Lalande
Journal:  MAGMA       Date:  2016-05-09       Impact factor: 2.310

Review 8.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

Review 9.  PET/MRI: Technical Challenges and Recent Advances.

Authors:  Jin Ho Jung; Yong Choi; Ki Chun Im
Journal:  Nucl Med Mol Imaging       Date:  2016-01-26

10.  Design, evaluation and initial imaging results of a PET insert based on strip-line readout for simultaneous PET/MRI.

Authors:  H Kim; Y Hua; H-T Chen; H-M Tsai; C-T Chen; G Karczmar; X Fan; D Xi; Q Xie; C-Y Chou; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2020-02-05       Impact factor: 1.455

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.