Marc M Van Hulle1,2,3, Richard Bowtell4, Matthew J Brookes4, Benjamin Wittevrongel5,6,7, Niall Holmes4, Elena Boto4, Ryan Hill4, Molly Rea4, Arno Libert1,3, Elvira Khachatryan1,3.
Abstract
BACKGROUND: Brain-computer interfaces decode intentions directly from the human brain with the aim to restore lost functionality, control external devices or augment daily experiences. To combine optimal performance with wide applicability, high-quality brain signals should be captured non-invasively. Magnetoencephalography (MEG) is a potent candidate but currently requires costly and confining recording hardware. The recently developed optically pumped magnetometers (OPMs) promise to overcome this limitation, but are currently untested in the context of neural interfacing.Entities:
Keywords: Brain-computer interface (BCI); Electroencephalography (EEG); Event-related field (ERF); Event-related potential (ERP); Magnetoencephalography (MEG); Optically pumped magnetometers (OPM); Steady-state visual evoked potential (SSVEP)
Mesh:
Year: 2021 PMID: 34376215 PMCID: PMC8356471 DOI: 10.1186/s12915-021-01073-6
Source DB: PubMed Journal: BMC Biol ISSN: 1741-7007 Impact factor: 7.431
Fig. 1.Motion-onset visual evoked potential. a A schematic showing one trial of the experimental paradigm. b ERF (filtered between 0.5 and 15 Hz) at the OPM channel exhibiting the largest M200 amplitude. The embedded scalp plot shows the spatial activation pattern when the maximal M200 amplitude is reached. The full line indicates the average ERF and the shaded area the 95% confidence interval. c ERP (filtered between 0.5 and 15 Hz) at the scalp-EEG channel having the largest N200 amplitude. The embedded scalp plot shows the spatial activation pattern when the maximal N200 amplitude is reached. The full line indicates the average ERP and the shaded area the 95% confidence interval. d M300 ERF (similar conventions as in b). e P300 ERP (similar conventions as in c). f Accuracy of decoding the gazed target at the best OPM sensor, scalp-EEG electrode and OPM gradiometer for increasing stimulus repetitions. Embedded scalp plots show the average decoding accuracy across the scalp. g Multi-channel decoding accuracy for scalp-EEG and OPM for an increasing number of stimulus repetitions
Fig. 2.Steady-state visual evoked potential. a Visual rendition of one trial in the experiment. b,c Stereotypical oscillating response when gazing at a 12 Hz stimulus in the time-domain at the OPM channel b and EEG electrode c having the largest amplitude. The full line indicates the average activation and the shaded area the 95% confidence interval. The scalp plots show the activation across the scalp when the amplitude is maximal. d Spatial distribution of the average SNR across all stimulus frequencies for OPM (left) and scalp-EEG (right). e SNR in response to each gazed frequency for the OPM-magnetometer, OPM-gradiometer and scalp-EEG channel having the largest average SNR. The line segment in the boxplots indicates the median accuracy; the box stretches from the 1st to the 3rd quartile; the lines extending from the box indicate the minimum and maximum value within 1.5 times the interquartile range from the 1st and 3rd quartile, respectively, and the crosses represent outliers. f Phase responses are consistent across trials for all three modalities. Each dot represents one trial. Note that the negative trend in the phase response with increasing frequency is expected due to the latency of the visual system [31, 33]
Fig. 3.Real-time spelling. a Visual rendition of one trial in the training session. Note that the frequency-phase combinations shown in the first panel are for exposition purposes and were not shown during the actual experiment. b The interface for the spelling session showed the word to be spelled, as well as the current set of letters that had been sequentially selected by the subject in their attempt to spell out the word. Eight of the crosses have been replaced with the characters required to spell the word and one cross was replaced with a backspace icon which could be used to undo a previous selection. No cues are given and the stimulation length was reduced to 2 s. c Post hoc simulation of the decoding accuracies with shorter stimulation lengths. The table shows the performance of the subjects during the real-time mind-spelling session
Fig. 4.a Schematic diagram of the full OPM setup. Note that during the real-time spelling experiment, the stimulus and acquisition computer were the same device. b View inside the magnetically shielded room. c Example of the rigid helmet with OPM sensors at different scalp locations