The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.

S Boyraz1, I Güngör.   

Abstract

OBJECTIVES: To investigate the effects of the modulus of the lens material on the intraocular pressure measurement using the Tono-Pen XL applanation tonometer through soft contact lenses.
METHOD: Thirty eyes of 15 patients with myopia were evaluated. Intraocular pressure (IOP) measurements were performed using Tono-Pen XL directly over cornea, and subsequently through three soft contact lenses made up of different lens materials. All were -3.00 diopter soft contact lenses: lotrafilcon A with a low water content (24%) and high modulus (1.4 MPa) (CL-I), balafilcon A with a moderate water content (36%) and moderate modulus (1.1 MPa) (CL-II), and vifilcon A with a moderate water content (55%) and low modulus (0.79 MPa) (CL-III). IOP measurements through contact lenses were compared with each other, and with direct corneal measurements.
RESULTS: The mean age of the patients (11 males and 4 females) was 26.86±5.62 years. All measurements obtained through CLs were significantly higher than the direct corneal measurements. The measurements through CLs differed by 4.61±0.54 mmHg (P=0,001), 2.9±0.46 mmHg (P=0.001), and 1.94±0.51 mmHg (P=0,003) for CL-I, CL-II and CL-III, respectively. In the paired comparisons of measurements through CLs, all comparisons were significant except the comparison of measurements through CL-II and CL-III (P=0.128).
CONCLUSION: IOP measurements through silicone-hydrogel contact lenses with a high modulus and low water content were higher compared to the other contact lenses. While measuring IOP through CLs, the clinicians should consider the effect of the lens material and the features of the device used.

Entities:  

Mesh:

Year:  2012        PMID: 23207914     DOI: 10.1007/s11845-012-0881-y

Source DB:  PubMed          Journal:  Ir J Med Sci        ISSN: 0021-1265            Impact factor:   1.568


  20 in total

1.  Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.

Authors:  Archana Bhan; Andrew C Browning; Sunil Shah; Robin Hamilton; Dinesh Dave; Harminder S Dua
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-05       Impact factor: 4.799

2.  Effect of corneal thickness on the accuracy of intraocular pressure measurement in rabbits after excimer laser photoablation.

Authors:  J Stahl; S Vold
Journal:  J Cataract Refract Surg       Date:  2000-05       Impact factor: 3.351

3.  Accuracy of intraocular pressure measurements with two different tonometers through bandage contact lenses.

Authors:  L K Mark; P A Asbell; M A Torres; S J Failla
Journal:  Cornea       Date:  1992-07       Impact factor: 2.651

4.  Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer.

Authors:  M Bafa; I Lambrinakis; M Dayan; M Birch
Journal:  Acta Ophthalmol Scand       Date:  2001-02

5.  Intraocular pressure measurement with the Tono-Pen through soft contact lenses.

Authors:  W C Panek; W A Boothe; D A Lee; E Zemplenyi; T H Pettit
Journal:  Am J Ophthalmol       Date:  1990-01-15       Impact factor: 5.258

6.  Tensile properties of soft contact lens materials.

Authors:  Ioannis Tranoudis; Nathan Efron
Journal:  Cont Lens Anterior Eye       Date:  2004-12       Impact factor: 3.077

7.  The effects of therapeutic contact lenses on intraocular pressure measurement.

Authors:  G D Scibilia; W H Ehlers; P C Donshik
Journal:  CLAO J       Date:  1996-10

8.  Intraocular pressure by noncontact tonometry with and without soft contact lenses.

Authors:  M S Insler; R G Robbins
Journal:  Arch Ophthalmol       Date:  1987-10

9.  Tono-Pen, a new tonometer.

Authors:  V Hessemer; R Rössler; K W Jacobi
Journal:  Int Ophthalmol       Date:  1989-01       Impact factor: 2.031

10.  Influence of lens material and intra-ocular pressure on the outcome of non-contact tonometry over soft contact lenses.

Authors:  Sudi Patel; Graeme Stevenson
Journal:  Cont Lens Anterior Eye       Date:  2009-02-04       Impact factor: 3.077

View more
  1 in total

1.  Rebound Tonometry over Soft Contact Lenses.

Authors:  Iva Krolo; Boze Mihaljevic; Aida Kasumovic; Freja Bagatin; Maja Malenica Ravlic; Jelena Skunca Herman
Journal:  Acta Inform Med       Date:  2020-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.