| Literature DB >> 34287314 |
Jonas Hörnsten1, Louise Axelsson2, Katarina Westling2,3.
Abstract
BACKGROUND: The aim of the study was to examine the treatment outcome for patients with cardiovascular implantable electronic device (CIED) infections after extraction.Entities:
Keywords: CIED-infections; endocarditis; extractions; long-term survival; septicemia
Year: 2021 PMID: 34287314 PMCID: PMC8293088 DOI: 10.3390/idr13030059
Source DB: PubMed Journal: Infect Dis Rep ISSN: 2036-7430
Baseline data for 165 patients who underwent removal for CIED infection in 2006–2015 at Karolinska University Hospital.
| Pocket Infection | Systemic Infection | All Infections | ||
|---|---|---|---|---|
|
| 104 | 61 | 165 | |
| Mean age (y) ± SD | 66.9 ± 15.0 | 69.8 (±12.4) | 67.0 ± 14.1 | |
| Sex female n (%) | 33 (31.7%) | 17 (27.9%) | 50 (30.3%) | 0.601 |
| Heart failure n (%) | 36 (34.6%) | 27 (44.3%) | 63 (38.1%) | 0.219 |
| Coronary artery disease n (%) | 26 (25.0%) | 19 (31.1%) | 45 (27.2%) | 0.394 |
| Valvular heart disease n (%) | 21 (20.2%) | 13 (21.3%) | 34 (20.6%) | 0.864 |
| Hypertension n (%) | 20 (19.2%) | 8 (13.1%) | 28 (17.0%) | 0.310 |
| CABG n (%) | 16 (15.4%) | 12 (19.7%) | 28 (16.9%) | 0.47 |
| Diabetes mellitus n (%) | 11 (10.6%) | 12 (19.6%) | 23 (13.9%) | 0.11 |
Abbreviations: CIED = cardiovascular implantable electronic devices, CABG = Coronary artery bypass graft surgery
Type of device and previous procedures in 165 patients who performed extraction due to CIED infection.
| Pocket Infection | Systemic Infection | All Infections | ||
|---|---|---|---|---|
|
| 104 | 61 | 165 | |
| Type of device | ||||
| PM | 53 (50.9%) | 36 (59.1%) | 89 (53.9%) | 0.615 |
| CRT-D | 21 (20.2%) | 13 (21.3%) | 34 (20.6%) | 0.86 |
| ICD | 19 (18.3%) | 8 (13.1%) | 27 (16.4%) | 0.39 |
| CRT-P | 11 (10.6%) | 4 (6.6%) | 15 (9.1%) | 0.38 |
| De novo implantation | 20 (19.2%) | 30 (49.2%) | 40 (30.3%) | 0.004 |
| Reimplantation | 84 (80.8%) | 31 (50.8%) | 115 (69.7%) | 0.004 |
| More than 2 CIED procedures | 29 (27.8%) | 12 (19.7%) | 41 (24.8%) | 0.23 |
Abbreviations: CIED = cardiovascular implantable electronic devices, PM = pacemaker, ICD = implantable cardioverter defibrillator, CRT-D = cardiac resynchronization therapy with defibrillator, CRT-P = cardiac resynchronization therapy with pacemaker.
Length of hospitalization, days of antibiotics treatment, and days until re-implantation in 165 patients with CIED infection.
| Pocket Infection (n = 104) | Systemic Infection (n = 61) | All Infections (n = 165) | ||
|---|---|---|---|---|
| Length of hospitalization | 5.7 (±5.9) | 38.6 (±15.7) | 17.9 (±19) | <0.001 |
| Days to reimplantation | 6.9 (±14.6) | 17.8 (±17.9) | 9.5 (±16) | 0.006 |
| Days on antibiotic treatment | 22.7 (±22.6) | 39.7(±16.02) | 29.9 (±21.9) | <0.001 |
Days in mean ± SD. Abbreviations: CIED = cardiovascular implantable electronic devices.
Microbiological findings in 165 patients with CIED removal due to infection.
| Pocket Infection (n = 104) | Systemic Infection (n = 61) | All Infections (n = 165) | ||
|---|---|---|---|---|
|
| 14 (13.5%) | 27 (44.2%) | 41 (24.8%) | <0.001 |
| Coagulase-negative staphylococci | 23 (22.1%) | 15 (24.5%) | 38 (23.0%) | 0.7 |
|
| 18 (17.3%) | 4 (6.5%) | 22 (13.3%) | 0.028 |
| 0 | 6 (9.8%) | 6 (3.6%) | - | |
| Other | 7 (6.7%) | 6 (9.8%) | 13 (7.9%) | 0.47 |
| Negative culture or PCR | 35 (33.5%) | 3 (4.9%) | 38 (23.0%) | 0.0023 |
| Not performed | 7 (6.7%) | 0 | 7 (4.2%) | - |
Data expressed in number (%). Abbreviations: CIED = cardiovascular implantable electronic devices, S. aureus = Staphylococcus aureus, CoNS = coagulase-negative staphylococci, C. acnes (Cutibacterium acnes), Other = identified microbe other than above mentioned, Negative = no findings in cultures or 16 S rRNA/PCR, None = no bacterial cultures or PCR testing performed.
Long-term mortality for patients who underwent an extraction due to CIED infection.
| Pocket Infection | Systemic Infection | All Infections | ||
|---|---|---|---|---|
| Number of patients | 104 | 61 | 165 | |
| 30—day mortality | 0 | 3 (17%) | 3 (1.8%) | - |
| 1—year mortality | 8 (7.7%) | 14 (22.3%) | 22 (13.3%) | 0.006 |
| 4—year mortality | 21 (20.1%) | 26 (42.6%) | 47 (28.4%) | 0.002 |
Data expressed in number (%). Abbreviations: CIED = cardiovascular implantable electronic devices.
Figure 1Long-term survival for patients with local and systemic CIED infection.
Figure 2Long-term survival for CIED infections caused by S. aureus and non-S aureus.
Figure 3Long-term survival for patients with >2 CIED procedures performed (Yes) and ≤2 procedures (No).