Literature DB >> 20470904

Cardiac implantable electronic device infections: presentation, management, and patient outcomes.

Khaldoun G Tarakji1, Eric J Chan, Daniel J Cantillon, Aaron L Doonan, Tingfei Hu, Steven Schmitt, Thomas G Fraser, Alice Kim, Steven M Gordon, Bruce L Wilkoff.   

Abstract

BACKGROUND: Indications for cardiac implantable electronic devices (CIEDs) are increasing. Although CIED infections occur infrequently, the impact of this outcome is expected to be substantial.
OBJECTIVE: The purpose of this study was to the evaluate the outcome of patients undergoing removal of infected CIEDs.
METHODS: A retrospective study was conducted of all patients with proven or suspected infected CIEDs who were referred to the Cleveland Clinic for system removal from January 2002 through March 2007.
RESULTS: A total of 412 patients (age 68 +/- 15 years) were included in the study. The majority of patients (241 [59%]) presented with localized infection involving the device pocket. The remaining 171 patients (41%) presented with endovascular infection but no evidence of inflammation of the device pocket. Of the total 414 pathogens isolated, 366 (88%) were aerobic gram-positive organisms, of which 90% were Staphylococcus species, and almost half of these were methicillin resistant. In-hospital mortality was 4.6% (19 patients). Only 2 deaths were extraction related. One-year mortality was 17%. Among the total cohort, 8 (1.9%) patients had relapsing infection within the first year. Among patients who had device replacement during the same hospitalization, 6 (2.6%) had relapsing infections within 1 year of reimplantation; 5 of these patients had systemic symptoms and were bacteremic upon initial presentation.
CONCLUSION: CIED infections are most often caused by Staphylococcus species, half of which are methicillin resistant. Percutaneous lead and device removal along with antibiotic therapy are effective as primary interventions. The overall relapse rate is 1.9%, and the relapse rate among patients who had reimplantation during the same hospitalization is 2.6%. Copyright 2010 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20470904     DOI: 10.1016/j.hrthm.2010.05.016

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  64 in total

Review 1.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

2.  Risk of ventricular tachyarrhythmias following improvement of left ventricular ejection fraction in patients with implantable cardiac defibrillators implanted for primary prevention of sudden cardiac death.

Authors:  Jayasree Pillarisetti; Rakesh Gopinathannair; Matthew J Haney; Bassem Abazid; Wasiq Rawasia; Madhu Yeruva Reddy; Niveditha Adabala; Sudharani Bommana; Martin Emert; Dhanunjaya Lakkireddy
Journal:  J Interv Card Electrophysiol       Date:  2017-02-01       Impact factor: 1.900

Review 3.  Infections associated with cardiac implantable electronic devices are misunderstood.

Authors:  Bruce L Wilkoff
Journal:  Tex Heart Inst J       Date:  2011

Review 4.  Transvenous Lead Extractions: Current Approaches and Future Trends.

Authors:  Adryan A Perez; Frank W Woo; Darren C Tsang; Roger G Carrillo
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

5.  The Diagnosis and Treatment of Pacemaker-Associated Infection.

Authors:  Michael Döring; Sergio Richter; Gerhard Hindricks
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

6.  Cardiac Implantable Electronic Device Infection in Patients at Risk.

Authors:  Khaldoun G Tarakji; Christopher R Ellis; Pascal Defaye; Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

7.  Large vegetation in a 60-year-old man with Enterococcus faecalis cardiac implantable electronic device infection.

Authors:  Sandrine Loron; Arnaud Dulac; Olivier Jegaden; Tristan Ferry
Journal:  BMJ Case Rep       Date:  2014-10-07

8.  Creation of the sole regional laser lead extraction program serving Atlantic Canada: initial experience.

Authors:  Kenneth J Williams; Scott O'Keefe; Jean-Francois Légaré
Journal:  Can J Surg       Date:  2016-06       Impact factor: 2.089

9.  New Insights into Predictors of Cardiac Implantable Electronic Device Infection.

Authors:  Hossein Sadeghi; Abolfath Alizadehdiz; Amirfarjam Fazelifar; Zahra Emkanjoo; Majid Haghjoo
Journal:  Tex Heart Inst J       Date:  2018-06-01

10.  Implantable cardioverter defibrillator lead-related methicillin resistant Staphylococcus aureus endocarditis: Importance of heightened awareness.

Authors:  Obiora F Anusionwu; Cheri Smith; Alan Cheng
Journal:  World J Cardiol       Date:  2012-07-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.