Literature DB >> 17481444

Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections.

Muhammad R Sohail1, Daniel Z Uslan, Akbar H Khan, Paul A Friedman, David L Hayes, Walter R Wilson, James M Steckelberg, Sarah Stoner, Larry M Baddour.   

Abstract

OBJECTIVES: We describe the management and outcome of permanent pacemaker (PPM) and implantable cardioverter-defibrillator (ICD) infections in a large cohort of patients seen at a tertiary care facility with expertise in device lead extraction.
BACKGROUND: Infection is a serious complication of PPM and ICD implantation. Optimal care of patients with these cardiac device infections (CDI) is not well defined.
METHODS: A retrospective review of all patients with CDI admitted to Mayo Clinic Rochester between January 1, 1991, and December 31, 2003, was conducted. Demographic and clinical data were collected, and descriptive analysis was performed.
RESULTS: A total of 189 patients met the criteria for CDI (138 PPM, 51 ICD). The median age of the patients was 71.2 years. Generator pocket infection (69%) and device-related endocarditis (23%) were the most common clinical presentations. Coagulase-negative staphylococci and Staphylococcus aureus, in 42% and 29% of cases, respectively, were the leading pathogens for CDI. Most patients (98%) underwent complete device removal. Duration of antibiotic therapy after device removal was based on clinical presentation and causative organism (median duration of 18 days for pocket infection vs. 28 days for endocarditis; 28 days for S. aureus infection vs. 14 days for coagulase-negative staphylococci infection [p < 0.001]). Median follow-up after hospital discharge was 175 days. Ninety-six percent of patients were cured with both complete device removal and antibiotic administration.
CONCLUSIONS: Cure of CDI is achievable in the large majority of patients treated with an aggressive approach of combined antimicrobial treatment and complete device removal. Based on findings of our large retrospective institutional survey and previously published data, we submit proposed management guidelines of CDI.

Entities:  

Mesh:

Year:  2007        PMID: 17481444     DOI: 10.1016/j.jacc.2007.01.072

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  135 in total

1.  Evolution of nasal carriage of methicillin-resistant coagulase-negative staphylococci in a remote population.

Authors:  David Lebeaux; François Barbier; Cécile Angebault; Lahcene Benmahdi; Etienne Ruppé; Benjamin Felix; Kevin Gaillard; Félix Djossou; Loïc Epelboin; Claire Dupont; Magaly Renard; Gilles Peroz; François Vandenesch; Michel Wolff; Antoine Andremont; Raymond Ruimy
Journal:  Antimicrob Agents Chemother       Date:  2011-11-07       Impact factor: 5.191

Review 2.  Current trends in the management of cardiac implantable electronic device (CIED) infections.

Authors:  Emanuele Durante-Mangoni; Irene Mattucci; Federica Agrusta; Marie-Françoise Tripodi; Riccardo Utili
Journal:  Intern Emerg Med       Date:  2012-06-29       Impact factor: 3.397

3.  The prevalence of methicillin resistant organisms among pacemaker and defibrillator implant recipients.

Authors:  David J Rodriguez; Aisha Afzal; Rudolph Evonich; David E Haines
Journal:  Am J Cardiovasc Dis       Date:  2012-05-15

4.  Complete removal of infected devices and simultaneous implantation of new devices for infective endocarditis after pacemaker implantation.

Authors:  Takuya Miura; Kazushige Inoue; Takenori Yokota; Takashi Iwata; Masao Yoshitatsu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-07-31

Review 5.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

6.  Cardiac device infection due to Streptococcus pneumoniae.

Authors:  Theresa T Liu; Pablo B Nery; David Birnie; Peter Jessamine; Kathryn N Suh
Journal:  Can J Infect Dis Med Microbiol       Date:  2012       Impact factor: 2.471

7.  Microbial colonization of electrocardiographic telemetry systems before and after cleaning.

Authors:  Alice Reshamwala; Kathryn McBroom; Yong Il Choi; Linda LaTour; Antoinette Ramos-Embler; Rowena Steele; Virginia Lomugdang; Margaret Newman; Colleen Reid; Yanfang Zhao; Bradi B Granger
Journal:  Am J Crit Care       Date:  2013-09       Impact factor: 2.228

8.  Cardiovascular implantable electronic device infections in left ventricular assist device recipients.

Authors:  Talha Riaz; Juhsien J C Nienaber; Larry M Baddour; Randall C Walker; Soon J Park; Muhammad Rizwan Sohail
Journal:  Pacing Clin Electrophysiol       Date:  2013-09-02       Impact factor: 1.976

9.  Role of ¹⁸F-FDG PET/CT in the diagnosis of infective endocarditis in patients with an implanted cardiac device: a prospective study.

Authors:  Maddalena Graziosi; Cristina Nanni; Massimiliano Lorenzini; Igor Diemberger; Rachele Bonfiglioli; Ferdinando Pasquale; Matteo Ziacchi; Mauro Biffi; Cristian Martignani; Michele Bartoletti; Fabio Tumietto; Giuseppe Boriani; Pier Luigi Viale; Stefano Fanti; Claudio Rapezzi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05-07       Impact factor: 9.236

10.  New Insights into Predictors of Cardiac Implantable Electronic Device Infection.

Authors:  Hossein Sadeghi; Abolfath Alizadehdiz; Amirfarjam Fazelifar; Zahra Emkanjoo; Majid Haghjoo
Journal:  Tex Heart Inst J       Date:  2018-06-01
View more