Literature DB >> 22523057

Long-term outcomes following infection of cardiac implantable electronic devices: a prospective matched cohort study.

Jean-Claude Deharo1, Amandine Quatre, Julien Mancini, Paul Khairy, Yvan Le Dolley, Jean-Paul Casalta, Eric Peyrouse, Sébastien Prévôt, Franck Thuny, Frédéric Collart, Didier Raoult, Gilbert Habib, Frédéric Franceschi.   

Abstract

OBJECTIVE: To assess long-term outcomes and predictors of mortality in patients treated according to current recommendations for cardiac implantable electronic device (CIED) infection.
DESIGN: Two-group matched cohort study.
SETTING: Tertiary-care institution. PATIENTS: Consecutive patients admitted for CIED infection between 2004 and 2008 were prospectively enrolled. Study subjects were matched to a cohort of uninfected CIED patients by age, sex and type of device.
INTERVENTIONS: In all infected patients, the therapeutic approach consisted of complete hardware removal whenever possible, antimicrobial therapy, and implantation of a new device, if indicated. Patients were systematically followed, with standardised outcomes assessment. MAIN OUTCOME MEASURES: All-cause mortality and predictors of long-term mortality.
RESULTS: 197 patients were included and matched 1:1 to controls. Pocket infections were present in 41.1% and definite or suspected infective endocarditis in 58.9%. Total or subtotal hardware removal was achieved in 98.5% of cases. Median follow up was 25 months (12-70). Mortality rates in the study group and controls were 14.3% vs 11.0% (NS) at 1 year and 35.4% vs 27.0% (p=NS) at 5 years. Independent predictors of long-term mortality were older age (HR=1.09, p<0.001), cardiac resynchronisation therapy (HR=3.70, p=0.001), thrombocytopenia (HR=5.10, p=0.003) and renal insufficiency (HR=2.66, p=0.006). In patients with reimplanted devices, epicardial right ventricular pacemakers were associated with higher mortality (HR=2.85, p=0.034).
CONCLUSION: In patients with CIED infection managed by recommended therapy, long-term mortality rates are similar to comparable controls. Independent predictors include patient and disease-related factors, in addition to implantation of right ventricular epicardial pacemakers.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22523057     DOI: 10.1136/heartjnl-2012-301627

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  26 in total

1.  Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study.

Authors:  Igor Diemberger; Rachele Bonfiglioli; Cristian Martignani; Maddalena Graziosi; Mauro Biffi; Stefano Lorenzetti; Matteo Ziacchi; Cristina Nanni; Stefano Fanti; Giuseppe Boriani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-08       Impact factor: 9.236

2.  Treatment of Infected Cardiac Implantable Electronic Devices.

Authors:  Abdulla Fakhro; Faryan Jalalabadi; Rodger H Brown; Shayan A Izaddoost
Journal:  Semin Plast Surg       Date:  2016-05       Impact factor: 2.314

3.  Role of 18F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis.

Authors:  Maryam Mahmood; Ayse Tuba Kendi; Saira Farid; Saira Ajmal; Geoffrey B Johnson; Larry M Baddour; Panithaya Chareonthaitawee; Paul A Friedman; M Rizwan Sohail
Journal:  J Nucl Cardiol       Date:  2017-09-14       Impact factor: 5.952

4.  Seasonal variations in cardiac implantable electronic device infections.

Authors:  Baptiste Maille; Linda Koutbi; Noémie Resseguier; Coralie Lemoine; Franck Thuny; Michael Peyrol; Jérôme Hourdain; Jean-Claude Deharo; Frédéric Franceschi
Journal:  Heart Vessels       Date:  2018-11-10       Impact factor: 2.037

5.  Association of selected factors with long-term prognosis and mortality after dual-chamber pacemaker implant.

Authors:  Maciej Dębski; Mateusz Ulman; Andrzej Ząbek; Krzysztof Boczar; Kazimierz Haberka; Marcin Kuniewicz; Jacek Lelakowski; Barbara Małecka
Journal:  Cardiol J       Date:  2018-08-29       Impact factor: 2.737

Review 6.  The causative agents in infective endocarditis: a systematic review comprising 33,214 cases.

Authors:  Christiana T Vogkou; Nikolaos I Vlachogiannis; Leonidas Palaiodimos; Antonis A Kousoulis
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-05-11       Impact factor: 3.267

7.  Management of Cardiac Electronic Device Infections: Challenges and Outcomes.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Jens Cosedis Nielsen
Journal:  Arrhythm Electrophysiol Rev       Date:  2016

8.  Snare sheath versus evolution sheath in transvenous lead extraction.

Authors:  Jihua Kong; Yilun Tian; Fei Guo; Feng Ze; Jiangbo Duan; Long Wang; Xuebin Li; Jihong Guo
Journal:  Int J Clin Exp Med       Date:  2015-11-15

9.  Management of Cardiac Implantable Electronic Device Infection.

Authors:  Cristian Podoleanu; Jean-Claude Deharo
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-11-29

10.  Chronic kidney disease in patients with cardiac rhythm disturbances or implantable electrical devices: clinical significance and implications for decision making-a position paper of the European Heart Rhythm Association endorsed by the Heart Rhythm Society and the Asia Pacific Heart Rhythm Society.

Authors:  Giuseppe Boriani; Irina Savelieva; Gheorghe-Andrei Dan; Jean Claude Deharo; Charles Ferro; Carsten W Israel; Deirdre A Lane; Gaetano La Manna; Joseph Morton; Angel Moya Mitjans; Marc A Vos; Mintu P Turakhia; Gregory Y H Lip
Journal:  Europace       Date:  2015-06-24       Impact factor: 5.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.