OBJECTIVE: To assess long-term outcomes and predictors of mortality in patients treated according to current recommendations for cardiac implantable electronic device (CIED) infection. DESIGN: Two-group matched cohort study. SETTING: Tertiary-care institution. PATIENTS: Consecutive patients admitted for CIED infection between 2004 and 2008 were prospectively enrolled. Study subjects were matched to a cohort of uninfected CIED patients by age, sex and type of device. INTERVENTIONS: In all infected patients, the therapeutic approach consisted of complete hardware removal whenever possible, antimicrobial therapy, and implantation of a new device, if indicated. Patients were systematically followed, with standardised outcomes assessment. MAIN OUTCOME MEASURES: All-cause mortality and predictors of long-term mortality. RESULTS: 197 patients were included and matched 1:1 to controls. Pocket infections were present in 41.1% and definite or suspected infective endocarditis in 58.9%. Total or subtotal hardware removal was achieved in 98.5% of cases. Median follow up was 25 months (12-70). Mortality rates in the study group and controls were 14.3% vs 11.0% (NS) at 1 year and 35.4% vs 27.0% (p=NS) at 5 years. Independent predictors of long-term mortality were older age (HR=1.09, p<0.001), cardiac resynchronisation therapy (HR=3.70, p=0.001), thrombocytopenia (HR=5.10, p=0.003) and renal insufficiency (HR=2.66, p=0.006). In patients with reimplanted devices, epicardial right ventricular pacemakers were associated with higher mortality (HR=2.85, p=0.034). CONCLUSION: In patients with CIED infection managed by recommended therapy, long-term mortality rates are similar to comparable controls. Independent predictors include patient and disease-related factors, in addition to implantation of right ventricular epicardial pacemakers.
OBJECTIVE: To assess long-term outcomes and predictors of mortality in patients treated according to current recommendations for cardiac implantable electronic device (CIED) infection. DESIGN: Two-group matched cohort study. SETTING: Tertiary-care institution. PATIENTS: Consecutive patients admitted for CIED infection between 2004 and 2008 were prospectively enrolled. Study subjects were matched to a cohort of uninfected CIED patients by age, sex and type of device. INTERVENTIONS: In all infectedpatients, the therapeutic approach consisted of complete hardware removal whenever possible, antimicrobial therapy, and implantation of a new device, if indicated. Patients were systematically followed, with standardised outcomes assessment. MAIN OUTCOME MEASURES: All-cause mortality and predictors of long-term mortality. RESULTS: 197 patients were included and matched 1:1 to controls. Pocket infections were present in 41.1% and definite or suspected infective endocarditis in 58.9%. Total or subtotal hardware removal was achieved in 98.5% of cases. Median follow up was 25 months (12-70). Mortality rates in the study group and controls were 14.3% vs 11.0% (NS) at 1 year and 35.4% vs 27.0% (p=NS) at 5 years. Independent predictors of long-term mortality were older age (HR=1.09, p<0.001), cardiac resynchronisation therapy (HR=3.70, p=0.001), thrombocytopenia (HR=5.10, p=0.003) and renal insufficiency (HR=2.66, p=0.006). In patients with reimplanted devices, epicardial right ventricular pacemakers were associated with higher mortality (HR=2.85, p=0.034). CONCLUSION: In patients with CIED infection managed by recommended therapy, long-term mortality rates are similar to comparable controls. Independent predictors include patient and disease-related factors, in addition to implantation of right ventricular epicardial pacemakers.
Authors: Maciej Dębski; Mateusz Ulman; Andrzej Ząbek; Krzysztof Boczar; Kazimierz Haberka; Marcin Kuniewicz; Jacek Lelakowski; Barbara Małecka Journal: Cardiol J Date: 2018-08-29 Impact factor: 2.737
Authors: Giuseppe Boriani; Irina Savelieva; Gheorghe-Andrei Dan; Jean Claude Deharo; Charles Ferro; Carsten W Israel; Deirdre A Lane; Gaetano La Manna; Joseph Morton; Angel Moya Mitjans; Marc A Vos; Mintu P Turakhia; Gregory Y H Lip Journal: Europace Date: 2015-06-24 Impact factor: 5.214