BACKGROUND: Miniplates are commonly used for the fixation of maxillofacial fracture segments. Removal of the hardware is controversial. A retrospective study of medical records was performed to observe the reasons for plate removal.Entities:
Mesh:
Substances:
Year: 2021 PMID: 34257626 PMCID: PMC8245212 DOI: 10.1155/2021/9947350
Source DB: PubMed Journal: ScientificWorldJournal ISSN: 1537-744X
History and location of fractures.
| Variable | Categories |
| % |
|---|---|---|---|
| History of trauma | Road traffic accident (RTA) | 37 | 88 |
| Fall | 5 | 12 | |
|
| |||
| Location of fracture | Mandibular | 19 | 45.2 |
| Maxillary | 6 | 14.3 | |
| Maxillary and mandibular | 2 | 4.8 | |
| Zygomatic | 4 | 9.5 | |
| Maxillary and zygomatic | 2 | 4.8 | |
| Mandibular and zygomatic | 1 | 2.4 | |
| Panfacial | 7 | 16.7 | |
| Lefort 3 | 1 | 2.4 | |
|
| 42 | 100 | |
Chief complaint of study subjects.
| Variable | Categories |
| % |
|---|---|---|---|
| Chief complaint | Pain with inability to open mouth/chewing food/discomfort | 10 | 23.9 |
| Pain with pus discharge/swelling/sinus opening | 17 | 40.4 | |
| Exposed/palpable hardware | 7 | 16.6 | |
| Elective/prophylactic removal in growing patient | 4 | 9.5 | |
| Feeling of heaviness/feeling of mental in mouth | 2 | 4.8 | |
| Loss of sensation | 1 | 2.4 | |
| Mobility of fracture segment | 1 | 2.4 |
Time of hardware removal of study subjects.
| Variable | Categories |
| % |
|---|---|---|---|
| Time of hardware removal | 1 day–1 week | 2 | 4.8 |
| 1 month–6 months | 9 | 21.4 | |
| 7 months–1 year | 12 | 28.5 | |
| >1 year-2 years | 5 | 11.9 | |
| >2 years-3 years | 5 | 11.9 | |
| 4 years-5 years | 5 | 11.9 | |
| 7 years | 2 | 4.8 | |
| 11 years-12 years | 2 | 4.8 | |
|
| |||
| Total | 42 | 100 | |
Type and process of removal of hardware of the study subjects.
| Variable | Categories |
| % |
|---|---|---|---|
| Type of hardware removed | Stainless steel (SS) | 20 | 47.6 |
| Titanium (ti) | 22 | 52.4 | |
|
| |||
| Type of plate based on the plate thickness | 1 mm | 12 | 28.6 |
| 1.5 mm | 20 | 47.6 | |
| 2 mm | 8 | 19 | |
| 2.5 mm | 2 | 4.8 | |
|
| |||
| Anaesthesia | General anesthesia (GA) | 25 | 59.5 |
| Local anesthesia (LA) | 17 | 40.5 | |
|
| |||
| Approach | Intraoral | 34 | 81 |
| Extraoral | 7 | 16.6 | |
| Combined | 1 | 2.4 | |
|
| |||
| Tooth involved | Yes | 9 | 21.4 |
| No | 33 | 78.6 | |
|
| |||
| Tooth extracted | Yes | 9 | 21.4 |
| No | 33 | 78.6 | |
|
| 42 | 100 | |