Literature DB >> 12729774

Miniplate removal in trauma and orthognathic surgery--a retrospective study.

M R Mosbah1, D Oloyede, D A Koppel, K F Moos, D Stenhouse.   

Abstract

Records of patients undergoing the surgical removal of miniplates placed during the management of maxillofacial trauma (n=49) and orthognathic surgery (n=16) in a single unit, over a 2-year period have been analysed. Data concerning indications for plating, age and sex distribution, site of plating, time between insertion and removal, antibiotic prophylaxis, general medical factors and clinical indications for plate removal were evaluated for all patients. In addition, data for trauma patients included the site of fracture, and time delay between injury and plate insertion. Infection and/or wound dehiscence were the predominant causes for plate removal in both groups, in spite of the routine use of prophylactic antibiotics in a predominantly young, healthy cohort of patients.A removal rate of approximately 10% was found in the two groups of patients. This low rate would seem to imply that the routine removal of miniplates is not clinically indicated.

Entities:  

Mesh:

Year:  2003        PMID: 12729774     DOI: 10.1054/ijom.2002.0344

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  15 in total

1.  Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients.

Authors:  T A Turvey; W P Proffit; C Phillips
Journal:  Int J Oral Maxillofac Surg       Date:  2010-12-24       Impact factor: 2.789

2.  Review of Maxillofacial Hardware Complications and Indications for Salvage.

Authors:  Jonatan Hernandez Rosa; Nathaniel L Villanueva; Paymon Sanati-Mehrizy; Stephanie H Factor; Peter J Taub
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2015-12-22

3.  Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.

Authors:  Ahmed Salah Mazeed; Mohammed Abdel-Raheem Shoeib; Samia Mohammed Ahmed Saied; Ahmed Elsherbiny
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-12-23

4.  Titanium osteosynthesis hardware in maxillofacial trauma surgery: to remove or remain? A retrospective study.

Authors:  Z Pan; P M Patil
Journal:  Eur J Trauma Emerg Surg       Date:  2013-11-19       Impact factor: 3.693

5.  A 4-Year Multicentre Audit of Complications Following ORIF Treatment of Mandibular Fractures.

Authors:  Sathesh Balasundram; Ferdinand J Kovilpillai; Stephen J Royan; Bee Chai Ma; Dharmindra Rajah Gunarajah; Tassha Hilda Adnan
Journal:  J Maxillofac Oral Surg       Date:  2019-02-25

6.  Surgical treatment of zygomatic bone fracture using two points fixation versus three point fixation--a randomised prospective clinical trial.

Authors:  Majeed Rana; Riaz Warraich; Salman Tahir; Asifa Iqbal; Constantin von See; André M Eckardt; Nils-Claudius Gellrich
Journal:  Trials       Date:  2012-04-12       Impact factor: 2.279

7.  Use of a single 2.0-mm locking AO reconstruction titanium plate in linear, non-comminuted, mandible fractures.

Authors:  Babu S Parmar; Kalpesh G Makwana; Aditi M Patel; Ramanuj C Tandel; Jay Shah
Journal:  Ann Maxillofac Surg       Date:  2014-01

8.  Mini-plate removal in maxillofacial trauma patients during a five-year retrospective study.

Authors:  Hyun-Chun Park; Su-Gwan Kim; Ji-Su Oh; Jae-Seek You; Won-Gi Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-08-24

9.  Causes and incidence of miniplate removal following Le Fort I osteotomy.

Authors:  Afshin Haraji; Mohammad Hosein Kalantar Motamedi; Nima Moharamnejad
Journal:  Eplasty       Date:  2009-10-12

10.  Hardware Removal in Maxillofacial Trauma: A Retrospective Study.

Authors:  Chithra Aramanadka; Abhay T Kamath; G Srikanth; Deepika Pai; Nishu Singla; Shriya Daundiyal; Avani Desai
Journal:  ScientificWorldJournal       Date:  2021-06-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.