BACKGROUND: Diagnosing the biochemical recurrence (BCR) of prostate cancer (PCa) is a clinical challenge, and early detection of BCR can help patients receive optimal treatment. We conducted a meta-analysis to define the diagnostic accuracy of PET/CT using 18F-labeled choline, fluciclovine, and prostate-specific membrane antigen (PSMA) in patients with BCR. METHODS: Multiple databases were searched until March 30, 2021. We included studies investigating the diagnostic accuracy of 18F-choline, 18F-fluciclovine, and 18F-PSMA PET/CT in patients with BCR. The pooled sensitivity, specificity, and detection rate of 18F-labeled tracers were calculated with a random-effects model. RESULTS: A total of 46 studies met the included criteria; 17, 16, and 13 studies focused on 18F-choline, fluciclovine, and PSMA, respectively. The pooled sensitivities of 18F-choline and 18F-fluciclovine were 0.93 (95% CI, 0.85-0.98) and 0.80 (95% CI, 0.65-0.897), and the specificities were 0.91 (95% CI, 0.73-0.97) and 0.66 (95% CI, 0.50-0.79), respectively. The pooled detection rates of 18F-labeled choline, fluciclovine and PSMA were 66, 74, and 83%, respectively. Moreover, the detection rates of 18F-labeled choline, fluciclovine, and PSMA were 35, 23, and 58% for a PSA level less than 0.5 ng/ml; 41, 46, and 75% for a PSA level of 0.5-0.99 ng/ml; 62, 57, and 86% for a PSA level of 1.0-1.99 ng/ml; 80, 92, and 94% for a PSA level more than 2.0 ng/ml. CONCLUSION: These three 18F-labeled tracers are promising for detecting BCR in prostate cancer patients, with 18F-choline showing superior diagnostic accuracy. In addition, the much higher detection rates of 18F-PSMA showed its superiority over other tracers, particularly in low PSA levels. SYSTEMATIC REVIEW REGISTRATION: PROSPERO, identifier CRD42020212531.
BACKGROUND: Diagnosing the biochemical recurrence (BCR) of prostate cancer (PCa) is a clinical challenge, and early detection of BCR can help patients receive optimal treatment. We conducted a meta-analysis to define the diagnostic accuracy of PET/CT using 18F-labeled choline, fluciclovine, and prostate-specific membrane antigen (PSMA) in patients with BCR. METHODS: Multiple databases were searched until March 30, 2021. We included studies investigating the diagnostic accuracy of 18F-choline, 18F-fluciclovine, and 18F-PSMA PET/CT in patients with BCR. The pooled sensitivity, specificity, and detection rate of 18F-labeled tracers were calculated with a random-effects model. RESULTS: A total of 46 studies met the included criteria; 17, 16, and 13 studies focused on 18F-choline, fluciclovine, and PSMA, respectively. The pooled sensitivities of 18F-choline and 18F-fluciclovine were 0.93 (95% CI, 0.85-0.98) and 0.80 (95% CI, 0.65-0.897), and the specificities were 0.91 (95% CI, 0.73-0.97) and 0.66 (95% CI, 0.50-0.79), respectively. The pooled detection rates of 18F-labeled choline, fluciclovine and PSMA were 66, 74, and 83%, respectively. Moreover, the detection rates of 18F-labeled choline, fluciclovine, and PSMA were 35, 23, and 58% for a PSA level less than 0.5 ng/ml; 41, 46, and 75% for a PSA level of 0.5-0.99 ng/ml; 62, 57, and 86% for a PSA level of 1.0-1.99 ng/ml; 80, 92, and 94% for a PSA level more than 2.0 ng/ml. CONCLUSION: These three 18F-labeled tracers are promising for detecting BCR in prostate cancer patients, with 18F-choline showing superior diagnostic accuracy. In addition, the much higher detection rates of 18F-PSMA showed its superiority over other tracers, particularly in low PSA levels. SYSTEMATIC REVIEW REGISTRATION: PROSPERO, identifier CRD42020212531.
Prostate cancer (PCa) is one of the most common malignancy in men worldwide and is also the fifth major cause of cancer-related death in men. It is estimated that over 300,000 PCa-related deaths occur in 2018 (1). In addition to its high morbidity and mortality, the recurrence and metastasis of prostate cancer are also troublesome in clinical practice (2, 3).It is challenging to detect initial recurrence and metastasis after prior treatment because of few obvious characteristics on early recurrent or metastatic lesions. PCa recurrence is usually considered when observing a rise in the serum prostate-specific antigen (PSA) level. This is regarded as biochemical recurrence (BCR) of PCa, and the definition of BCR is a serum PSA level over a threshold of 0.2 ng/ml twice after radical prostatectomy (RP) or an absolute increase in PSA level of 2 ng/ml over the lowest posttreatment PSA level after radiation therapy (RT) (4, 5).The key issue for patients with BCR is the early and correct identification of recurrent or metastatic disease, which is essential for further devising treatment strategies since treatment varies based on the presence of local recurrence, regional lymph node and distant viscera or bone metastasis (6). Conventional imaging modalities consisting of CT, bone scan, and MRI have been used for patients with advanced PCa, but their roles in detecting minimal or occult lesions are limited (7, 8). These conventional imaging modalities also have low sensitivity and specificity in detecting patients with BCR, especially those with a low PSA level. According to the 2020 American Society of Clinical Oncology (ASCO) guidelines, next-generation imaging (NGI) such as PET/CT, PET/MRI, and whole-body MRI is recommended for use in patients with rising PSA after prior treatment when conventional imaging findings are negative (9). Radioactive tracers such as choline and fluciclovine have been used for prostate cancer staging, restaging, and treatment response evaluation. Meanwhile, prostate-specific membrane antigen (PSMA), a new radiopharmaceutical that binds to prostate cancer-specific target, has demonstrated outstanding detection rate for recurrent or metastatic lesions among patients with BCR.Choline is an essential element of phospholipids in the cellular wall, and the increased uptake of choline means increased metabolism of the cell membrane components of malignant tumors (10). 11C-choline was approved by the Food and Drug Administration (FDA) in 2012, but its short half-life limits its widespread use in PET/CT centers without onsite cyclotrons. Later, 18F-labeled choline was developed, and its longer half-life has solidified 18F-choline PET/CT as a significant imaging modality in patients with suspected PCa recurrence (11, 12). 18F-Fluciclovine (anti-1-amino-3-18F-fluorocyclobutane-1-carboxylic acid, 18F-FACBC), as a synthetic amino acid that is upregulated in PCa, is an option for molecular imaging in patients with BCR, which was approved by the FDA in 2016 (13, 14). The main advantage of 18F-fluciclovine is its low urinary excretion, which allows for better detection and localization of PCa recurrence in patients with rising PSA level (15). PSMA is a type 2 transmembrane protein that is more highly expressed in the prostate cancer cell membrane than in normal tissues (16–18). Therefore, PSMA has become a promising target for imaging prostate cancer (19). 68Ga-PSMA PET/CT has been proven to improve the detection of metastatic disease and the monitoring of treatment effects in patients with PCa (20). Most recently, 68Ga-PSMA-11, as the first PSMA PET agent, has been approved by the FDA. 18F-labeled PSMA has also begun to be used in clinical practice, and its long half-life and high resolution in PET/CT images have further increased the detection rate of PSMA-targeted imaging in subtle or occult metastases (21, 22). Moreover, 18F-PSMA-1007 PET/CT can differentiate local recurrence from physical uptake in the urinary bladder or ureter due to non-urinary clearance (23, 24).Some previous studies have compared the diagnostic roles of 11C-choline, 18F-fluciclovine, and 68Ga-PSMA PET/CT in patients with BCR, showing that 68Ga-PSMA PET/CT has a superior detection rate (25). Even so, there have been some clinical challenges existing in 68Ga-PSMA PET/CT due to certain shortcomings including its short half-life, non-ideal energies and the limited availability of 68Ga. Compared with 68Ga and 11C, 18F, as a longer half-life nuclide, has many advantages such centralized production in a cyclotron facility and more favorable positron energies for imaging, thereby motivating the development of 18F-labeled analogs. Currently, growing clinical experience has revealed the high diagnostic accuracy of some 18F-labeled tracers in PCa patients with BCR. However, the effectiveness of 18F-labeled choline, fluciclovine, and PSMA remains unclear because of limited number of studies. Herein, we aimed to perform a meta-analysis to review and compare the diagnostic value of 18F-labeled choline, fluciclovine, and PSMA PET/CT imaging for detecting BCR in patients with PCa, in order to provide better creditability for clinical practice.
Methods
The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines was used for our study (26). Our review has registered on the international prospective register of systematic reviews (PROSPERO) (CRD 42020198861).
Search Strategy
A literature research was conducted with scientific databases, including PubMed, EMBASE, and Web of Science, until March 30, 2021. A search algorithm was developed based on a combination of keywords (“choline” OR “fluciclovine” OR “FACBC” OR “PSMA” OR “DCFPyL” OR “DCFBC” OR “1007”) AND (“prostate cancer” OR “prostate neoplasm”) AND (“biochemical recurrence” OR “biochemical failure”) AND (“PET/CT” OR “positron emission tomography/computed tomography”) AND (“18F” OR “fluorine”).Two authors independently screened and evaluated these studies. The reference lists of all relevant studies were further checked to find more suitable studies. A third author was responsible for disagreement and solved the controversy between two authors through discussion.
Selection of Studies
Studies using 18F-labeled tracers such as 18F-choline, 18F-fluciclovine, and 18F-PSMA were evaluated. Studies were included according to the following criteria: (a) sample size >10; (b) patients who had evidence of BCR underwent PET/CT; (c) studies evaluating the diagnostic accuracy of 18F-labeled tracers in prostate cancer patients with BCR; (d) histological results, imaging, or clinical follow-up as a reference standard. Studies on other tracers were not included. Abstracts, reviews, and case reports were also not included. If the studies included duplicate patients, we reviewed and included the study with the largest sample or the most recent study performed. The included studies were limited to those published in English.
Quality Assessment
The quality of included studies was critically assessed by two independent authors according to the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. This tool comprises four domains (patient selection, index test, reference standard, and flow and timing), and each domain was used to assess the risk of bias. Next, applicability was also considered according to patient selection, the index test, and the reference standard.
Data Extraction
Two authors collected various parameters and outcomes from each eligible study as follows: author, country, publication year, study design, number of patients, age, pre-PET PSA level, reference criteria, scanner model, ligands, and injection dose and the detection rate as well as true positive (TP), false positive (FP), false negative (FN), and true negative (TN) PET/CT with different tracers in patients with BCR. All discrepancies were resolved by consensus and ultimately based on the decision of the third author.
Statistical Analysis
For studies reporting the diagnostic performance of 18F-PSMA, 18F-choline, and 18F-fluciclovine PET/CT in patients with BCR, 2 × 2 table was used to calculate TP, FP, TN, and FN. The pooled sensitivity and specificity were calculated by a random-effects model. We developed a hierarchical summary receiver operating curve and calculated the area under the curve. We presented forest plots with 95% confidence intervals (CIs) for the sensitivity and specificity of each study. In addition, the detection rates of PET tracers were extracted and pooled using a random-effects model. If possible, subgroup analysis was considered based on different PSA serum values.Heterogeneity within studies was evaluated using Cochran’s Q test and the I² statistic (27). An I² value greater than 50% was indicative of substantial heterogeneity. The funnel plot test and Egger’s test were used to assess the publication bias. All statistical analyses were performed using Stata 15.0 and RevMan 5.3. P-value <0.05 was considered to be statistically significant (28).
Results
The flow chart demonstrates an overview of the search and selection process (
). The initial search yielded 480 studies, of which 95 were duplicates. Subsequently, after reviewing the titles and abstracts, we excluded 238 studies for the following reasons: 170 studies were case reports, reviews, and academic meeting abstracts, 11 were basic studies, five applications in other diseases, and 52 studies used different radiotracers and imaging modalities. Of the remaining studies, 75 studies were not relevant to our aims, and most of them investigated the impact of novel PET/CT tracers in treatment management for patients with PCa or focused on evaluating metastatic disease. In addition, 26 studies did not provide sufficient information and were excluded. Thus, only 46 studies were finally included. Of these, 17 studies focused on the role of 18F-choline PET/CT in prostate cancer patients with BCR (29–45). The numbers of included studies regarding 18F-fluciclovine and 18F-PSMA PET/CT were 16 and 13, respectively (46–74).
–
outline the characteristics of each eligible study.
Figure 1
Flow of study search.
Table 1
Study characteristics of 18F-choline PET/CT.
Author
Publication Year
Country
Design
Patients
Mean age/Range
PSA (ng/mL)
Scancer Modality
Ligand
Mean dose
Reference standard
Pelosi
2008
Italy
R
56
67.9 ± 7
4.59 ± 7.87
Discovery ST unit, GE
18F-choline
185–259 MBq
Multiple
Kwee
2012
US
P
50
69.0 ± 8.9
3.2 (0.2–18.2)
Philips Gemini TF-64
18F-fluorocholine
2.6 MBq/kg
Multiple
Panebianco
2012
Italy
P
84
56–72
1.63
Discovery ST, GE
18F-choline
185-259 MBq
Multiple
Schillaci
2012
Italy
P
49
70. 9 ± 7
4.13 ± 4.56
Discovery ST, GE
18F-choline
370 MBq
Biopsy
Detti
2013
Italy
R
170
——
3.5 ± 8.8
PET/CT Philips TOF
18F-fluorocholine
3.7 MBq/kg
Follow-up
Marzola
2013
Italy
R
233
69.4 ± 6.5
7.4 ± 13.6
Discovery STE
18F-fluorocholine
3 MBq/kg
Piccardo
2014
Italy
P
21
77.2 ± 5.1
5.8 ± 3.4
Discovery ST, GE
18F-choline
3MBq/kg
Multiple
Morigi
2015
Australia
P
38
68(54–81)
1.72 ± 2.54
Philips Ingenuity TF 64
18F-fluorocholine
3.5 MBq/kg
Biopsy
Rodado-Marina
2015
Spain
R
233
68 ± 7.1
5.3 ± 8.7
GE and Siemens equipments
18F-fluorocholine
4 MBq/kg
Multiple
Cimitan
2015
Italy
R
1,000
69.68 ± 7.67
3.30
GE Discovery LS; Siemens Biograph 16 HT or Biograph mCT; GE Discovery ST8,
18F-choline
3.0–3.5 MBq/kg
Multiple
Simone
2015
Italy
P
146
68
0.6 (0.43–0.76)
Siemens Biograph Hi-Rez 16;
18F-choline
4 MBq/kg
Multiple
Emmett
2018
Australia
P
91
64 (59–69)
0.42 (0.29–0.93)
——
18F-choline
3.6 MBq/kg
Multiple
Giovacchini
2019
Italy
R
192
73.2 ± 6.6
9.53 ± 16.70
GE Discovery 710
18F-fluorocholine
3.7 MBq/kg
Multiple
Witkowska-Patena
2019
Poland
P
40
68.6 ± 6.5
0.75 ± 0.6
GE Discovery 710
18F-fluorocholine
248 ± 35 MBq
Multiple
Sánchez
2020
Spain
P
108
69 ± 6.7
4.9 ± 5.2
Siemens Biograph mCT
18F-choline
370 MBq
Multiple
Zattoni
2020
Italy
R
2,798
72 (66.29–77.0)
2.0 (0.1–3.0)
——
18F-choline
2.5-3.7 MBq/kg
de Leiris
2020
France
R
115
73.2 (56–89)
9.4 (7.1–18.4)
GE Discovery 690
18F-choline
3.7 MBq/kg
Multiple
A multiple reference standards including biopsy, other imaging modalities and follow-up.
Table 3
Study characteristics of 18F-PSMA PET/CT.
Author
Publication Year
Country
Design
Patients
Mean age/year
PSA (ng/ml)
Scancer Modality
Tracer
Mean dose
Reference standard
Rahbar
2018
Germany
R
100
68.75 ± 7.6
3.3 6 ± 6.11
Siemens Healthcare
18F-PSMA-1007
4 MBq/kg
——
Eiber
2018
Germany
R
261
72 (49–88)
0.961 (0.01–400.0)
Siemens Biograph mCT
18F‐rhPSMA‐7
333 ± 44 MBq
——
Giesel
2018
Germany
R
251
70 (48–86)
1.2 (0.2–228)
Siemens Biograph mCT
18F-PSMA-1007
301 ± 46 MBq
——
Rousseau
2018
Canada
P
130
69.1 ± 6.5
5.20 ± 6.50
GE Discovery PET/CT 600 or 690
18F-DCFPyL
369.2 ± 47.2 MBq
——
Wondergem
2019
Netherlands
R
248
71 (67–75)
Philips Ingenuity TF, Siemens Biograph 16
18F-DCFPyL
311 MBq
——
Mena
2019
USA
P
90
66 (50–81)
2.5 ± 5.9
GE Discovery MI
18F-DCFPyL
299.9 ± 15.5 MBq
——
Song
2019
USA
P
72
71.5 ± 7.2
3.0 (0.23-698.4)
GE Discovery MI
18F-DCFPyL
338.8 ± 25.3 MBq
——
Witkowska-Patena
2019
Poland
P
40
68.6 ± 6.5
0.75 ± 0.6
GE Discovery 710,
18F-PSMA-1007
295.5 ± 14.1 MBq
——
Rowe
2020
USA
P
31
63 (45–74)
0.4 (0.2–28.3)
GE Discovery RX 64 or Biograph mCT 128
18F-DCFPyL
<333 MBq
——
Chaussé
2020
Canada
R
93
70.4(51-87)
2.27 (0.07–51.09)
GE Discovery ST
18F-DCFPyL
333 ± 37 MBq
Multiple
Dietlein
2021
Germany
R
70
70.1 ± 5.5
18F-JK-PSMA-7
348 ± 55 MBq
——
Koschel
2021
Australia
P
98
68.0 (66.0–71.0)
0.32 (0.28–0.36)
GE Discovery 710
18F-DCFPyL
250 ± 50 MBq
Imaging
Perry
2021
New Zealand
R
222
71 (49–89)
0.51 (0.08–58.9)
GE Discovery 690, 710
18F-DCFPyL
250 ± 50 MBq
——
A multiple reference standards including biopsy, other imaging modalities and follow-up.
Flow of study search.Study characteristics of 18F-choline PET/CT.A multiple reference standards including biopsy, other imaging modalities and follow-up.Study characteristics of 18F-fluciclovine PET/CT.A multiple reference standards including biopsy, other imaging modalities and follow-up.Study characteristics of 18F-PSMA PET/CT.A multiple reference standards including biopsy, other imaging modalities and follow-up.show the results of the quality assessment of each eligible study for 18F-choline, 18F-fluciclovine, and 18F-PSMA, respectively. Patient selection was not considered the source of bias because all studies had qualified patient selection criteria. For the index test and reference standard, some studies did not adopt the blinding method when interpreting the positive scan of the PET/CT findings, and we rated these studies as high or unclear levels regarding the risk of bias and applicability concern. Similarly, unclear or high levels were displayed on the applicability concern of flow and timing because of the different follow-up times and multiple reference standards.
Figure 2
(A) Quality Assessment of Diagnostic Accuracy Studies-2 analysis of study bias in 18F-choline cohort. (B) Quality Assessment of Diagnostic Accuracy Studies-2 analysis of study bias in 18F-fluciclovine cohort. (C) Quality Assessment of Diagnostic Accuracy Studies-2 analysis of study bias in 18F prostate-specific membrane antigen (PSMA) cohort.
(A) Quality Assessment of Diagnostic Accuracy Studies-2 analysis of study bias in 18F-choline cohort. (B) Quality Assessment of Diagnostic Accuracy Studies-2 analysis of study bias in 18F-fluciclovine cohort. (C) Quality Assessment of Diagnostic Accuracy Studies-2 analysis of study bias in 18F prostate-specific membrane antigen (PSMA) cohort.
Diagnostic Performance of 18F-Choline and 18F-Fluciclovine PET/CT
Seventeen studies reported the diagnostic performance of 18F-choline, and the summary sensitivity and specificity of 18F-choline PET/CT in patients with BCR were 0.93 (95% CI, 0.85–0.96) and 0.91 (95% CI, 0.73–0.97), respectively (
). The summary sensitivity and specificity drawn from studies on 18F-fluciclovine were 0.80 (95% CI, 0.65–0.89) and 0.66 (95% CI, 0.50–0.79), respectively (
). However, the summary sensitivity and specificity were not constructed for 18F-PSMA PET/CT imaging because these studies mostly focused on the detection rate in patients with BCR. Summary receiver operating characteristic (SROC) curves of 18F-choline and 18F-fluciclovine were demonstrated in
.
Figure 3
Forest plot of the proportion of 18F-choline positron emission tomography/computed tomography (PET/CT) sensitivity and specificity in prostate cancer patients with biochemical recurrence.
Figure 4
Forest plot of the proportion of 18F-fluciclovine PETCT sensitivity and specificity in prostate cancer patients with biochemical recurrence.
Figure 5
(A) SROC curve for the diagnostic accuracy of 18F-choline PET/CT in prostate cancer patients with biochemical recurrence. (B) SROC curve for the diagnostic accuracy of 18F-fluciclovine PET/CT in prostate cancer patients with biochemical recurrence. SROC, summary receiver operating characteristic.
Forest plot of the proportion of 18F-choline positron emission tomography/computed tomography (PET/CT) sensitivity and specificity in prostate cancer patients with biochemical recurrence.Forest plot of the proportion of 18F-fluciclovine PETCT sensitivity and specificity in prostate cancer patients with biochemical recurrence.(A) SROC curve for the diagnostic accuracy of 18F-choline PET/CT in prostate cancer patients with biochemical recurrence. (B) SROC curve for the diagnostic accuracy of 18F-fluciclovine PET/CT in prostate cancer patients with biochemical recurrence. SROC, summary receiver operating characteristic.
Detection Rate of 18F-Choline, 18F-Fluciclovine, and 18F-PSMA PET/CT
The pooled detection rate of 18F-choline PET/CT was 66%, lower than 74% of 18F-fluciclovine PET/CT. In addition, the pooled detection rate of 18F-PSMA PET/CT was 83% (
). Meanwhile, the detection rates of 18F-labeled choline, fluciclovine, and PSMA were 35, 23, and 58% for a PSA level less than 0.5 ng/ml (
); 41, 46, and 75% for a PSA level of 0.5–0.99 ng/ml (
); 62, 57, and 86% for a PSA level of 1.0–1.99 ng/ml (
); 80, 92, and 94% for a PSA level more than 2.0 ng/ml (
).
Figure 6
Forest plot of the proportion of 18F-labeled choline (A), fluciclovine (B) and PSMA (C) PET/CT positivity of prostate cancer patients with biochemical recurrence.
Figure 7
Forest plot of the proportion of 18F-labeled choline, fluciclovine and PSMA positivity of prostate cancer patients with BCR for PSA less than 0.5 ng/ml.
Figure 8
Forest plot of the proportion of 18F-labeled choline, fluciclovine, and PSMA positivity of prostate cancer patients with BCR for PSA 0.5–0.99 ng/ml.
Figure 9
Forest plot of the proportion of 18F-labeled choline, fluciclovine, and PSMA positivity of prostate cancer patients with BCR for PSA 1.0–1.99 ng/ml.
Figure 10
Forest plot of the proportion of 18F-labeled choline, fluciclovine, and PSMA positivity of prostate cancer patients with BCR for PSA more than 2.0 ng/ml.
Forest plot of the proportion of 18F-labeled choline (A), fluciclovine (B) and PSMA (C) PET/CT positivity of prostate cancer patients with biochemical recurrence.Forest plot of the proportion of 18F-labeled choline, fluciclovine and PSMA positivity of prostate cancer patients with BCR for PSA less than 0.5 ng/ml.Forest plot of the proportion of 18F-labeled choline, fluciclovine, and PSMA positivity of prostate cancer patients with BCR for PSA 0.5–0.99 ng/ml.Forest plot of the proportion of 18F-labeled choline, fluciclovine, and PSMA positivity of prostate cancer patients with BCR for PSA 1.0–1.99 ng/ml.Forest plot of the proportion of 18F-labeled choline, fluciclovine, and PSMA positivity of prostate cancer patients with BCR for PSA more than 2.0 ng/ml.
Discussion
Our meta-analysis included studies investigating the diagnostic roles of three novel 18F-labeled tracers applied in prostate cancer patients with BCR. From our study, the summary sensitivity and specificity of 18F-choline and 18F-fluciclovine PET/CT were 0.93 and 0.91, and 0.80 and 0.66, respectively. For the detection rate, the pooled detection rates of 18F-labeled choline, fluciclovine, and PSMA were 66, 74, and 83%, respectively. Meanwhile, we observed a higher detection rate of biochemically recurrent PCa with 18F-PSMA compared with choline and fluciclovine PET/CT for the different PSA level subgroups.Multiple PET/CT radiotracers have been developed and experimented in recent years, motivating the wide use of PET/CT or PET/MRI in patients with PCa for staging, restaging, and response evaluation (75, 76). 18F-fluciclovine PET/CT showed a superior advantage over 11C-choline PET/CT in patients with BCR and further aid guiding decision-making in regard to patients’ treatment strategy (48, 77). In addition, PSMA PET/CT has shown superior diagnostic accuracy for recurrence and metastases of prostate cancer than fluciclovine and choline. A meta-analysis defined the diagnostic accuracy of PET/CT imaging using 11C-choline, 18F-fluciclovine, or 68Ga-PSMA, showing that 68Ga-PSMA PET/CT has a nearly equal sensitivity but the highest specificity among these tracers for PET/CT imaging in detecting biochemically recurrent PCa (25).In contrast, our meta-analysis focused on only long-half radionuclides as 18F-labeled tracers and summarized the diagnostic accuracy of 18F-labeled choline, fluciclovine, and PSMA in detecting patients with BCR. Our study revealed that 18F-PSMA had the highest detection rate at different PSA levels, and the detection rate was related to the PSA level. These results were consistent with another meta-analysis that compared the detection rate of biochemically recurrent PCa between PSMA-targeted radiotracers and 18F-fluciclovine, finding that PSMA-targeted radiotracers demonstrate a greater detection rate than 18F-fluciclovine (78). A study compared prospectively paired 18F-fluciclovine and PSMA PET/CT scans for localizing recurrence of PCa after prostatectomy in patients with a PSA level <2.0 ng/ml (55). They found that PSMA PET/CT showed higher detection rates and should be the tracer choice when PET/CT imaging is considered for patients with biochemical recurrence after radical prostatectomy with low PSA concentrations (≤2.0 ng/ml). The same conclusion was drawn from another prospective study paired that compared 18F-PSMA and 18F-fluorocholine PET/CT in patients with BCR (42). The advantage of PSMA-targeted PET/CT imaging could be attributed to the high expression of PSMA in PCa and its metastases.In late 2020, 68Ga-PSMA-11 became the first PSMA PET tracer to be approved by the FDA, which may facilitate widespread adaptation. Despite this, there also have been some limitations related to 68Ga-PSMA PET/CT because of the short half-life, non-ideal energies, and limited availability of 68Ga, limiting its clinical application in detecting occult or metastatic lesions in the prostate bed (62, 79). However, 18F-PSMA analogs seemed to be more favorable due to their longer half-life and a higher physical spatial resolution (23), and 18F-PSMA-1007, as a second-generation 18F-labeled PSMA tracer, demonstrated high labeling yields, better tumor uptake, and hepatobiliary excretion, making it an ideal PSMA-target tracer for diagnostic imaging in patients with BCR (21, 23). Our meta-analysis found the pooled detection rate with 18F-PSMA of 58% for a PSA level of less than 0.5 ng/ml, 75% for a PSA level of 0.5 to 0.99 ng/ml, and 86% for a PSA level of 1.0 to 1.99 ng/ml. These detection rates are equal or higher than those in recent studies involving 68Ga PSMA PET/CT (80, 81).Compared with FDA approval of 68Ga-PSMA-11 in late 2020, 11C-choline and 18F-fluciclovine PET/CT have one temporary advantage as they have been granted FDA approval early. They were more accessible and used in the US and Europe. Many studies compared the diagnostic utility of 18F-fluciclovine with 11C-choline PET/CT imaging, showing a better performance in terms of lesion detection rate (48, 82). A recent meta-analysis demonstrated that 18F-fluciclovine had the similar sensitivity and detection rate compared with 11C-choline, but lower specificity than 11C-choline (83). Unlike the short physical half-life of 11C-choline, the radiofluorine of 18F-choline provides a long physical half-life (109.8 min), allowing for centralized manufacture and distribution. These intrinsic advantages of 18F labeling has made 18F-choline PET/CT valuable in staging patients with PCa and detecting recurrently PCa metastases after initial treatment (33, 84). There were limited studies in comparing directly to determine which imaging modality has a better diagnostic efficiency between 18F-choline and 18F-fluciclovine. In our meta-analysis, 18F-choline had a higher sensitivity and specificity than 18F-fluciclovine through assessing the summary sensitivity and specificity. 18F-choline also has better detection rates than 18F-fluciclovine at PSA levels under 0.5 ng/ml and 1.0–1.99 ng/ml, but the pooled detection rate of 18F-fluciclovine was higher than that of 18F-choline in biochemically recurrent PCa. This difference could be interpreted by different biological processes between amino acid transport and choline expression.
Limitations
There were several limitations to this study that should be mentioned. First, we only evaluated the diagnostic accuracy of both 18F-choline and 18F-fluciclovine PET/CT in patients with BCR, and the pooled sensitivity and specificity for 18F-PSMA PET/CT were not feasible because of insufficient published data. Second, there were significant heterogeneities among institutions, PET/CT scanners, radiotracers, and prior treatment of patients, which increased the risk of bias and led to significant heterogeneity among 18F-choline, 18F-fluciclovine and 18F-PSMA PET/CT. Third, most of the included studies were retrospective analyses, had small sample sizes, had limited reference standards, and lacked prospective, large sample, and interagent comparison studies. Fourth, there was publication bias according to Egger’s test regarding the included studies of 18F-choline, 18F-flocilovine, and 18F-PSMA PET/CT, limiting the interpretation of the data to some degree.
Conclusion
PET/CT imaging with 18F-choline, 18F-fluciclovine, and 18F-PSMA is promising in detecting prostate cancer patients with BCR. 18F-PSMA PET/CT demonstrated a significantly higher detection rate over 18F-choline and 18F-fluciclovine for different PSA levels, particularly in PSA level less than 2.0 ng/ml.
Data Availability Statement
The original contributions presented in the study are included in the article/supplementary material. Further inquiries can be directed to the corresponding author.
Author Contributions
Conceived and designed the experiments: RW, GS, and RT. Performed the experiments: GS, RW, and MH. Analyzed the data: RW, GS, and RT. Analyzed tools: GS and MH. Wrote the paper: RW and RT. Provided critical input into the design and drafting of the manuscript: RW, GS, and RT. All authors contributed to the article and approved the submitted version.
Funding
This study was supported by the National Natural Science Foundation of China (81971653).
Conflict of Interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Table 2
Study characteristics of 18F-fluciclovine PET/CT.
Author
Publication Year
Country
Design
Patients
Mean age/Range
PSA (ng/mL)
Scancer Modality
Ligand
Mean dose
Reference standard
Schuster
2011
US
P
50
68.3 ± 8.1
6.62 ± 7.63
Discovery DLS, GE
18F-fluciclovine
199.8–484.7 MBq
Multiple
Kairemo
2014
Finland
R
26
68.1 ± 5.8
7.9 ± 14.6
Siemens Biograph
18F-fluciclovine
328 ± 56.8 MBq
Multiple
Nanni
2016
Italy
P
89
69
6.99
Discovery STE, GE
18F-fluciclovine
370 MBq
Follow-up
Odewole
2016
USA
R
53
67.57± 8.03
7.2 ± 8.3
GE Discovery DLS or 690
18F-fluciclovine
358 ± 52.9MBq
Follow-up
Bach-Gansmo
2017
Norway, Italy, UK
R
143
67
5.43
——
18F-fluciclovine
310 MBq
Follow-up
Miller
2017
USA
R
110
67.4 ± 7.37
5.87 ± 7.65
GE Discovery DLS or 690
18F-fluciclovine
370 MBq
Multiple
Akin-Akintayo
2018
USA
P
24
70.8 ± 5.7
8.5 ± 6.1
GE Discovery 690
18F-fluciclovine
370 ± 13 MBq
Biopsy
Jambor
2018
Finland
P
32
65 (49–76)
12 (4.1–35)
GE Discovery 690
18F-fluciclovine
369 ± 10 MBq
Biopsy
Andriole
2019
US
P
213
66.4 ± 7.75
4.24 ± 10.22
——
18F-fluciclovine
370 ± 20% MBq
Multiple
Calais
2019
US
P
50
68 (64–74)
0·48 (0·38–0·83)
Siemens Biograph64 and GE Discovery
18F-fluciclovine
381 MBq
Multiple
England
2019
US
R
28
67.1 (53–77)
0.44(0.1–1)
Siemens Biograph
18F-fluciclovine
370 MBq
Follow-up
Savir-Baruch
2019
US
R
152
68.73 ± 7.92
2.06 (0.006–120)
Philips Ingenuity TF PET/CT
18F-fluciclovine
9.97 ± 1.18mci
——
Teyateeti
2020
US
R
94
65.7 (42.5–80.3)
GE Discovery 710, MI and Siemens Biograph 64
18F-fluciclovine
370 MBq
Multiple
Garza
2021
US
R
78
68.7 (48–87)
0.72(<0.05–1.99)
——
18F-fluciclovine
——
Imaging
Michael
2021
US
R
103
69.79 ± 7.88
5.77 ± 9.98
Siemens Biograph
18F-fluciclovine
10 mci
Imaging
Nakamoto
2021
US
R
165
71.1 ± 8.8
3.1 (1.0–9.6)
GE Discovery 600, 690, or MI
18F-fluciclovine
389 ± 59 MBq
Multiple
A multiple reference standards including biopsy, other imaging modalities and follow-up.
Authors: Oladunni O Akin-Akintayo; Ashesh B Jani; Oluwaseun Odewole; Funmilayo I Tade; Peter T Nieh; Viraj A Master; Leah M Bellamy; Raghuveer K Halkar; Chao Zhang; Zhengjia Chen; Mark M Goodman; David M Schuster Journal: Clin Nucl Med Date: 2017-01 Impact factor: 7.794
Authors: Gerald W Hull; Farhang Rabbani; Farhat Abbas; Thomas M Wheeler; Michael W Kattan; Peter T Scardino Journal: J Urol Date: 2002-02 Impact factor: 7.450
Authors: G L Wright; B M Grob; C Haley; K Grossman; K Newhall; D Petrylak; J Troyer; A Konchuba; P F Schellhammer; R Moriarty Journal: Urology Date: 1996-08 Impact factor: 2.649
Authors: Bital Savir-Baruch; Petra Lovrec; Abhishek A Solanki; William H Adams; Paul M Yonover; Gopal Gupta; David M Schuster Journal: AJR Am J Roentgenol Date: 2019-06-19 Impact factor: 3.959
Authors: Laura Evangelista; Fabio Zattoni; Andrea Guttilla; Giorgio Saladini; Filiberto Zattoni; Patrick M Colletti; Domenico Rubello Journal: Clin Nucl Med Date: 2013-05 Impact factor: 7.794
Authors: Matthias Eiber; Markus Kroenke; Alexander Wurzer; Lena Ulbrich; Lena Jooß; Tobias Maurer; Thomas Horn; Kilian Schiller; Thomas Langbein; Gabriel Buschner; Hans-Jürgen Wester; Wolfgang Weber Journal: J Nucl Med Date: 2019-12-13 Impact factor: 10.057
Authors: Edouard J Trabulsi; R Bryan Rumble; Hossein Jadvar; Thomas Hope; Martin Pomper; Baris Turkbey; Andrew B Rosenkrantz; Sadhna Verma; Daniel J Margolis; Adam Froemming; Aytekin Oto; Andrei Purysko; Matthew I Milowsky; Heinz-Peter Schlemmer; Matthias Eiber; Michael J Morris; Peter L Choyke; Anwar Padhani; Jorge Oldan; Stefano Fanti; Suneil Jain; Peter A Pinto; Kirk A Keegan; Christopher R Porter; Jonathan A Coleman; Glenn S Bauman; Ashesh B Jani; Jeffrey M Kamradt; Westley Sholes; H Alberto Vargas Journal: J Clin Oncol Date: 2020-01-15 Impact factor: 44.544
Authors: Divya Yadav; Hyunsoo Hwang; Wei Qiao; Rituraj Upadhyay; Brian F Chapin; Chad Tang; Ana Aparicio; Maria A Lopez-Olivo; Stella K Kang; Homer A Macapinlac; Tharakeswara K Bathala; Devaki Shilpa Surasi Journal: Radiol Imaging Cancer Date: 2022-03
Authors: Venkata Avinash Chikatamarla; Satomi Okano; Peter Jenvey; Alexander Ansaldo; Matthew J Roberts; Stuart C Ramsay; Paul A Thomas; David A Pattison Journal: EJNMMI Res Date: 2021-12-20 Impact factor: 3.138