AMBER: a scanning multiple-beam equalization system for chest radiography.

H Vlasbloem1, L J Kool.   

Abstract

Conventional chest radiography is limited by the small useful exposure range of radiographic film. The wide variation in absorption thickness of different parts of the chest results in areas of under- and over-exposure. An advanced multiple-beam equalization system, AMBER, controls local exposure delivered to the film. The system has a row of 20 modulators in front of the x-ray tube, each able to change the height of the local slit beam during scanning. Changes are made in response to measurements from a linear detector array in front of the film cassette. This array consists of 20 individually functioning detectors coupled through electronic feedback loops to the 20 modulators. A scan is obtained in 0.8 second with a local exposure time of approximately 50 msec. AMBER results in radiographs with significantly improved exposure of the mediastinum without overexposure of the lungs.

Mesh:

Year:  1988        PMID: 3420279     DOI: 10.1148/radiology.169.1.3420279

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

Authors:  Juergen Biederer; Tobias Gottwald; Hendrik Bolte; Christian Riedel; Sandra Freitag; Richard Van Metter; Martin Heller
Journal:  Eur Radiol       Date:  2006-09-09       Impact factor: 5.315

2.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

Review 3.  Medical imaging.

Authors:  L Kreel
Journal:  Postgrad Med J       Date:  1991-04       Impact factor: 2.401

4.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  Role of equalisation mammography of dense breasts.

Authors:  D B Plewes; J M Sabol; I Soutar; A Chevrier; R Shumak
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

6.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

7.  MR imaging of lung parenchyma at 0.2 T: evaluation of imaging techniques, comparative study with chest radiography and interobserver analysis.

Authors:  Nasreddin D Abolmaali; Jan Schmitt; Sabine Krauss; Frank Bretz; Michael Deimling; Volkmar Jacobi; Thomas J Vogl
Journal:  Eur Radiol       Date:  2004-02-10       Impact factor: 5.315

8.  A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy.

Authors:  Steve Burion; Michael A Speidel; Tobias Funk
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

9.  X-ray dose reduction through adaptive exposure in fluoroscopic imaging.

Authors:  Steve Burion; Tobias Funk
Journal:  J Vis Exp       Date:  2011-09-11       Impact factor: 1.355

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.