Literature DB >> 3416521

Cemented total hip arthroplasty with contemporary techniques. A five-year minimum follow-up study.

G M Russotti1, M B Coventry, R N Stauffer.   

Abstract

A retrospective clinical and roentgenographic review was performed on 251 consecutive cemented total hip arthroplasties (THA) performed from 1978 to 1980 that had been followed a minimum of five years (range, five to seven years). All arthroplasties involved the use of a Harris Design II femoral stem, an intramedullary plug, a cement gun, and pulsatile lavage of both the acetabulum and the femoral canal. At the final follow-up examination, 98% of the patients had excellent results. The average Harris hip score was 47 points preoperative and 97 points postoperative. There were three definitely loose femoral stems, one probably loose, and two possibly loose. There was one loose acetabular component, no revisions or operations were performed. When comparing this series with a similar study, there were statistically improved results in all parameters. Results from this study of cemented THAs using contemporary techniques and prosthetic stem design represent the standard for comparison when evaluating alternative THA systems.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3416521

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  8 in total

1.  Three- to five-year results with the cementless Harris-Galante acetabular component used in hybrid total hip arthroplasty.

Authors:  H Kienapfel; W Pitzer; P Griss
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

2.  [Effect of femoral cementing technique on results. Comparison between retrograde technique and vacuum application].

Authors:  S Ungethuem; B Lehner; T Reitzel; P J Buckley; H Mau; S J Breusch
Journal:  Orthopade       Date:  2005-07       Impact factor: 1.087

3.  Cementless total hip arthroplasty with AML, PCA and HGP prostheses.

Authors:  S K Hwang; J S Park
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

4.  An in vitro comparison of tibial tray cementation using gun pressurization or pulsed lavage.

Authors:  Ulf J Schlegel; Klaus Püschel; Michael M Morlock; Katrin Nagel
Journal:  Int Orthop       Date:  2014-03-12       Impact factor: 3.075

Review 5.  Total hip arthroplasty.

Authors:  J S Siopack; H E Jergesen
Journal:  West J Med       Date:  1995-03

6.  Cementless Gustilo-Kyle and BIAS total hip arthroplasty: 2- to 5-year results.

Authors:  H Kienapfel; J Martell; A Rosenberg; J Galante
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

7.  Early complications following cemented modular hip hemiarthroplasty.

Authors:  Niall P T Sullivan; Andrew W Hughes; Ruth L Halliday; Abigail L Ward; Tim J S Chesser
Journal:  Open Orthop J       Date:  2015-01-31

8.  Current trends of stem use in hemiarthroplasty for femoral neck fracture in South Korea.

Authors:  Young-Kyun Lee; Ki-Choul Kim; Byung-Ho Yoon; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  Clin Orthop Surg       Date:  2014-08-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.