Literature DB >> 1586576

Three- to five-year results with the cementless Harris-Galante acetabular component used in hybrid total hip arthroplasty.

H Kienapfel1, W Pitzer, P Griss.   

Abstract

In this paper we present our 3- to 5-year results after hybrid total hip replacement using the cementless porous coated Harris-Galante acetabular component and the cemented Griss femoral component in 39 patients with 40 implantations. Postoperatively, mild to moderate pain was experienced by 16.1% of patients, mostly following hard activity. A slight to moderate limp occurred in 24.2%. All patients were able to walk more than 1000 m. Full-time use of support was required by 2.8%. The postoperative range of motion was increased in 93.9%. Radiographically, none of the acetabular or femoral components had to be classified as unstable. Only one acetabular component displayed complete (i.e., along all interface zones) radiolucency and was therefore classified as possibly unstable.

Entities:  

Mesh:

Year:  1992        PMID: 1586576     DOI: 10.1007/bf00388088

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  17 in total

1.  [The alumina oxide ceramic-metal composite endoprosthesis. A new hip endoprosthesis for partially cement free implantation (author's transl)].

Authors:  P Griss; G Heimke; H F von Andrian-Werburg
Journal:  Arch Orthop Unfallchir       Date:  1975

2.  Anchorage of the femoral head prosthesis to the shaft of the femur.

Authors:  J CHARNLEY
Journal:  J Bone Joint Surg Br       Date:  1960-02

3.  The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities.

Authors:  J P Davies; D O O'Connor; D W Burke; M Jasty; W H Harris
Journal:  Clin Orthop Relat Res       Date:  1988-04       Impact factor: 4.176

4.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

5.  Sintered fiber metal composites as a basis for attachment of implants to bone.

Authors:  J Galante; W Rostoker; R Lueck; R D Ray
Journal:  J Bone Joint Surg Am       Date:  1971-01       Impact factor: 5.284

6.  [Histology of the implant-bone interface in cemented and uncemented endoprostheses].

Authors:  T Herren; W Remagen; R Schenk
Journal:  Orthopade       Date:  1987-06       Impact factor: 1.087

7.  Morphological and biomechanical aspects of Al2O3 ceramic joint replacement. Experimental results and design considerations for human endoprostheses.

Authors:  P Griss; G Heimke; H Von Andrian-Werburg; B Krempien; S Reipa; H J Lauterbach; H J Hartung
Journal:  J Biomed Mater Res       Date:  1975-07

8.  Radiographic comparison of cementing techniques in total hip arthroplasty.

Authors:  D W Roberts; R Poss; K Kelley
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

9.  Quantitative analysis of tissue growth into human porous total hip components.

Authors:  S D Cook; R L Barrack; K A Thomas; R J Haddad
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

10.  Metal/cement interface strength in cemented stem fixation.

Authors:  A M Ahmed; S Raab; J E Miller
Journal:  J Orthop Res       Date:  1984       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.