Fracture Incidence of WaveOne and Reciproc Files during Root Canal Preparation of up to 3 Posterior Teeth: A Prospective Clinical Study.

Clóvis Stephano Pereira Bueno1, Daniel Pinto de Oliveira2, Rina Andrea Pelegrine1, Carlos Eduardo Fontana1, Daniel Guimarães Pedro Rocha1, Carlos Eduardo da Silveira Bueno3.   

Abstract

INTRODUCTION: Reciprocating instruments were developed to improve and simplify the preparation of the root canal system by allowing greater centralization of the canal and requiring a shorter learning curve. Despite the risk of instrument separation, using a reciprocating instrument in more than 1 case is a relatively common clinical practice. The aim of this study was to evaluate the fracture resistance of Reciproc (R25; VDW, Munich, Germany) and WaveOne (Primary; Dentsply Maillefer, Ballaigues, Switzerland) instruments according to the number of uses during the preparation of root canals in up to 3 posterior teeth.
METHODS: A prospective clinical study was conducted by 3 experienced specialists who performed treatment of 358 posterior teeth (1130 canals) over a period of 12 months using 120 reciprocating instruments, 60 of which were Reciproc R25 and 60 were WaveOne Primary. The motion used during instrumentation followed the recommendations of the respective manufacturers. After each use, the instruments were observed under a dental operating microscope at 8× magnification. In the case of fracture or deformation, the instrument was discarded.
RESULTS: None of the instruments showed any signs of deformation, but 3 instruments fractured (0.26% of the number of canals and 0.84% of the number of teeth). All fractures occurred in mandibular molars (1 WaveOne Primary file during the third use and 2 Reciproc R25 files, 1 during the first use and the other during the third use).
CONCLUSIONS: There was a low incidence of fracture when reciprocating files were used in up to 3 cases of endodontic treatment in posterior teeth.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Instrument fracture; Reciproc; WaveOne; posterior teeth; reciprocating movement

Mesh:

Year:  2017        PMID: 28343932     DOI: 10.1016/j.joen.2016.12.024

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?

Authors:  Emmanuel João Nogueira Leal Silva; Rafael Santos Attademo; Marcia Cristina Dutra da Silva; Karem Paula Pinto; Henrique Dos Santos Antunes; Victor Talarico Leal Vieira
Journal:  Clin Oral Investig       Date:  2020-11-21       Impact factor: 3.573

2.  The incidence of nickel-titanium endodontic hand file fractures: A 7-year retrospective study in a tertiary care hospital.

Authors:  Arun Kumar Patnana; Ankita Chugh; Vinay Kumar Chugh; Pravin Kumar
Journal:  J Conserv Dent       Date:  2020-10-10

3.  Ex-Vivo Comparison of Torsional Stress on Nickel-Titanium Instruments Activated by Continuous Rotation or Adaptive Motion.

Authors:  Joo Yeong Lee; Sang Won Kwak; Jung-Hong Ha; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

4.  Dynamic torque analysis of rotary and reciprocating instruments during root canal instrumentation in simulated canals by an endodontist or a general dentist.

Authors:  Marco Antonio Z Loureiro; Giampiero Rossi-Fedele; Octavio G Amezcua; Paulo O Carmo Souza; Julio A Silva; Carlos Estrela; Daniel A Decurcio
Journal:  J Conserv Dent       Date:  2020-11-05

5.  Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study.

Authors:  Liliana Machado Ruivo; Marcos de Azevedo Rios; Alexandre Mascarenhas Villela; Alexandre Sigrist de Martin; Augusto Shoji Kato; Rina Andrea Pelegrine; Ana Flávia Almeida Barbosa; Emmanuel João Nogueira Leal Silva; Carlos Eduardo da Silveira Bueno
Journal:  Restor Dent Endod       Date:  2021-09-09

6.  Fracture Incidence of Kedo-S Square Pediatric Rotary Files: A Prospective Clinical Study.

Authors:  Lakshimi Lakshmanan; Ganesh Jeevanandan; Prabhadevi C Maganur; Satish Vishwanathaiah
Journal:  Eur J Dent       Date:  2021-12-04

7.  Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instruments.

Authors:  Victor de Ornelas Peraça; Samantha Rodrigues Xavier; Fabio de Almeida Gomes; Luciane Geanini Pena Dos Santos; Erick Miranda Souza; Fernanda Geraldo Pappen
Journal:  Restor Dent Endod       Date:  2021-04-29

8.  Topographic Features of Five K-file Brands in Iranian Market: A Scanning Electron Microscopic Study.

Authors:  Arash Shahravan; Hedayat Gorjestani; Arash Izadi; Nazanin Mortazavi
Journal:  Iran Endod J       Date:  2018

Review 9.  Separation of Nickel-Titanium Rotary and Reciprocating Instruments: A Mini-Review of Clinical Studies.

Authors:  Marcelo Santos Coelho; Marcos de Azevêdo Rios; Carlos Eduardo da Silveira Bueno
Journal:  Open Dent J       Date:  2018-10-25
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.