Literature DB >> 26372255

Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments.

D Zhao1, Y Shen2,3, B Peng4, M Haapasalo2.   

Abstract

AIM: To compare the cyclic fatigue resistance of HyFlex CM, Twisted Files (TF), K3XF, Race, and K3, and evaluate the effect of autoclave sterilization on the cyclic fatigue resistance of these instruments both before and after the files were cycled.
METHODOLOGY: Five types of NiTi instruments with similar size 30, .06 taper were selected: HyFlex CM, TF, K3XF, Race and K3. Files were tested in a simulated canal with a curvature of 60° and a radius of 3 mm. The number of cycles to failure of each instrument was determined to evaluate cyclic fatigue resistance. Each type of instruments was randomly divided into four experimental groups: group 1 (n = 20), unsterilized instruments; group 2 (n = 20), pre-sterilized instruments subjected to 10 cycles of autoclave sterilization; group 3 (n = 20), instruments tested were sterilized at 25%, 50% and 75% of the mean cycles to failure as determined in group 1, and then cycled to failure; group 4 (n = 20), instruments cycled in the same manner as group 3 but without sterilization. The fracture surfaces of instruments were examined by scanning electron microscopy (SEM).
RESULTS: HyFlex CM, TF and K3XF had significantly higher cyclic fatigue resistance than Race and K3 in the unsterilized group 1 (P < 0.05). Autoclave sterilization significantly increased the MCF of HyFlex CM and K3XF (P < 0.05) both before and after the files were cycled. SEM examination revealed a typical pattern of cyclic fatigue fracture in all instruments.
CONCLUSIONS: HyFlex CM, TF and K3XF instruments composed of new thermal-treated alloy were more resistant to fatigue failure than Race and K3. Autoclaving extended the cyclic fatigue life of HyFlex CM and K3XF.
© 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  NiTi instrument; autoclave sterilization; cyclic fatigue; thermal treated

Mesh:

Substances:

Year:  2015        PMID: 26372255     DOI: 10.1111/iej.12550

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  11 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

3.  The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu
Journal:  Restor Dent Endod       Date:  2017-11-02

Review 4.  Rotary science and its impact on instrument separation: A focused review.

Authors:  Sandhya Anand Khasnis; Prem Prakash Kar; Apoorva Kamal; Jayaprakash D Patil
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

5.  The Effect of Multiple Autoclave Sterilization on the Cyclic Fatigue of Three Heat-Treated Nickel-Titanium Rotary Files: EdgeFile X7, Vortex Blue, and TRUShape.

Authors:  Reham Sharroufna; Mohammed Mashyakhy
Journal:  Biomed Res Int       Date:  2020-12-14       Impact factor: 3.411

6.  Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instruments.

Authors:  Victor de Ornelas Peraça; Samantha Rodrigues Xavier; Fabio de Almeida Gomes; Luciane Geanini Pena Dos Santos; Erick Miranda Souza; Fernanda Geraldo Pappen
Journal:  Restor Dent Endod       Date:  2021-04-29

7.  Cyclic Fatigue Resistance of Heat-Treated Nickel-Titanium Instruments.

Authors:  Mário Tanomaru-Filho; Camila Galletti Espir; Ana Carolina Venção; Nathaly Macedo-Serrano; Jader Camilo-Pinto; JulianeMaria Guerreiro-Tanomaru
Journal:  Iran Endod J       Date:  2018

8.  Comparison of cyclic fatigue resistance of XP-endo Shaper, HyFlex CM, FlexMaster and Race instruments.

Authors:  Mehmet Adiguzel; Ipek Isken; Ismail Ilker Pamukcu
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-09-18

9.  Effect of Sterilization on Cyclic Fatigue Resistance of Proflexendo Endodontic Rotary Files.

Authors:  Emad O Alshwaimi
Journal:  Saudi J Med Med Sci       Date:  2019-02-08

10.  Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review.

Authors:  Emmanuel João Nogueira Leal Silva; Mayara Zanon; Fernanda Hecksher; Felipe Gonçalves Belladonna; Rafaela Andrade de Vasconcelos; Tatiana Kelly da Silva Fidalgo
Journal:  Restor Dent Endod       Date:  2020-03-31