Literature DB >> 34122759

Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation.

Tarun Goyal1, Siddharth S Sethy2, Sajid Ansari2, Lakshmana Das2, Souvik Paul2.   

Abstract

PURPOSE: Acetate templates were commonly used for templating for total hip arthroplasty. With digital radiographs having replaced conventional analogue radiographs, newer techniques are required. We describe a method for templating images of digital radiographs using conventional acetate templates, which is independent of a magnification marker or PACS system.
METHODS: Fifty-one patients (64 hips) who were treated with primary THA were prospectively evaluated. Templating was done by keeping the acetate template directly over the digital image of the radiograph on a liquid crystal display (LCD) monitor, after calibrating the linear scale generated by the digital radiography machine. The size of prosthesis predicted on this templating technique was compared with the actual sizes used during the surgery. Inter-observer and intra-observer reliabilities were assessed. Our calibration method was further validated by comparing the size of the cup calculated on postoperative radiograph using digital templating software (mediCAD Hectec GmbH) and the actual size used during surgery.
RESULTS: Accurate size was predicted for 36.7% of the acetabular cup and 35.9% of femoral stems. The accuracy within ± one size was 89.9% for acetabular cups and 91.4% for femoral stems. Excellent inter-observer and intra-observer reliability were seen for both femoral and acetabular components.
CONCLUSION: The method described provides an accurate, reproducible, convenient and low-cost technique of preoperative templating. It combines the ease of using acetate templates with the convenience of being able to use digital images, without the need for expensive software. © Indian Orthopaedics Association 2020.

Entities:  

Keywords:  Digital radiograph; Templating; Total hip arthroplasty

Year:  2020        PMID: 34122759      PMCID: PMC8149513          DOI: 10.1007/s43465-020-00300-6

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


  23 in total

1.  Soft tissue balancing: the hip.

Authors:  Robert B Bourne; Cecil H Rorabeck
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

2.  Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty.

Authors:  Kuen Tak Suh; Sang Jin Cheon; Dae Woong Kim
Journal:  Acta Orthop Scand       Date:  2004-02

3.  Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

Authors:  Vignesh P Krishnamoorthy; Rajamani Perumal; Alfred J Daniel; Pradeep M Poonnoose
Journal:  J Clin Orthop Trauma       Date:  2015-05-11

4.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

5.  Accuracy of digital preoperative templating in 100 consecutive uncemented total hip arthroplasties: a single surgeon series.

Authors:  Shahril R Shaarani; Gavin McHugh; Denis A Collins
Journal:  J Arthroplasty       Date:  2012-07-31       Impact factor: 4.757

6.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

7.  The accuracy of digital templating in uncemented total hip arthroplasty.

Authors:  Patrick Gamble; Justin de Beer; Danielle Petruccelli; Mitchell Winemaker
Journal:  J Arthroplasty       Date:  2009-06-02       Impact factor: 4.757

8.  The accuracy of preoperative templating in cementless total hip arthroplasty.

Authors:  Aasis Unnanuntana; Dominic Wagner; Stuart B Goodman
Journal:  J Arthroplasty       Date:  2008-04-08       Impact factor: 4.757

9.  Accuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty.

Authors:  Jong Ki Shin; Seung Min Son; Tae Woo Kim; Won Chul Shin; Jung Sub Lee; Kuen Tak Suh
Journal:  Hip Pelvis       Date:  2016-12-28

10.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

View more