The accuracy of preoperative templating in cementless total hip arthroplasty.

Aasis Unnanuntana1, Dominic Wagner, Stuart B Goodman.   

Abstract

We evaluated the accuracy and clinical usefulness of preoperative templating in 109 cementless total hip arthroplasties. The size of the prosthesis was exactly predicted in 46 (42.2%) acetabular and 75 (68.8%) femoral components. The accuracy increased to greater than 90% if the prosthesis size was within 1 or 2 sizes (above or below) for femoral component and acetabular components, respectively. Having a contralateral total hip arthroplasty as a guide for preoperative templating was associated with greater accuracy in predicting the femoral component size only. Eighty-eight percent of the acetabular components were oriented inside the presumed safe range for inclination; 42% of the acetabular components were in the presumed safe range of anteversion. The mean postoperative leg length discrepancy was 0.9 +/- 6.8 mm; 93.5% had a discrepancy within 10 mm.

Entities:  

Mesh:

Year:  2008        PMID: 18534455     DOI: 10.1016/j.arth.2007.10.032

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  21 in total

1.  Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

Authors:  Vignesh P Krishnamoorthy; Rajamani Perumal; Alfred J Daniel; Pradeep M Poonnoose
Journal:  J Clin Orthop Trauma       Date:  2015-05-11

2.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

3.  Radiographic templating of total hip arthroplasty for femoral neck fractures.

Authors:  Dror Lakstein; Ira Bachar; Ronen Debi; Omri Lubovsky; Ornit Cohen; Zachary Tan; Ehud Atoun
Journal:  Int Orthop       Date:  2016-06-07       Impact factor: 3.075

Review 4.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

5.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

6.  Are the left and right proximal femurs symmetric?

Authors:  Ernest Y Young; Jeremy Gebhart; Daniel Cooperman; Nicholas U Ahn
Journal:  Clin Orthop Relat Res       Date:  2012-11-21       Impact factor: 4.176

7.  Significance of proximal femoral computed tomography scanning in the prediction of femoral prosthesis before total hip arthroplasty.

Authors:  Yizhong Li; Jinkuang Lin; Jing Zhang; Jianlong Li; Xuedong Yao; Huafeng Zhuang; Yanjun Zeng
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-01-29

8.  Hip Offset and Leg Length Equalization in Direct Anterior Approach Total Hip Arthroplasty without Preoperative Templating.

Authors:  Ian Hasegawa; Anne R Wright; Samanth N Andrews; Emily Unebasami; Cass K Nakasone
Journal:  Hawaii J Health Soc Welf       Date:  2019-11

9.  How to best measure femoral length and lateralisation after total hip arthroplasty on antero-posterior pelvic radiographs.

Authors:  Nicolas Bonin; Laurent Jacquot; Laurent Boulard; Patrick Reynaud; Mo Saffarini; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-03-01       Impact factor: 3.075

10.  The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty.

Authors:  R Kearney; A H Shaikh; J M O'Byrne
Journal:  Ir J Med Sci       Date:  2013-01-25       Impact factor: 1.568