| Literature DB >> 34075199 |
Yujie Mou1, Huan Xiang1,2, Lin Lin1, Kelan Yuan1, Xin Wang1, Yaying Wu1, Jinjin Min1, Xiuming Jin3.
Abstract
This study aims to investigate the reliability and efficacy of maximum fluorescein tear break-up time (FTBUTmax) in diagnosing dry eye disease (DED). 147 participants were enrolled in this study. Ocular symptoms were assessed by Ocular Surface Disease Index (OSDI). The fluorescein tear break-up time (FTBUT) examination, corneal fluorescein staining (CFS), and Schirmer I test were performed on both eyes. Each participant underwent 3 consecutive FTBUT tests, and five types of FTBUT values including FTBUTmax, the minimum FTBUT (FTBUTmin), the first FTBUT (FTBUT1), the average of three FTBUTs (FTBUT123) and the average of the first and second FTBUT (FTBUT12) were recorded. FTBUTmax was larger than the other FTBUT values, but no differences were found among the values of FTBUT1, FTBUT123, FTBUT12 and FTBUTmin. In the ROC analysis, FTBUTmax had the largest or the second largest area under the ROC (AUROC) in all three DED diagnostic criteria, while FTBUTmin had the least AUROC of them. ROC efficacy of FTBUTmax was significantly higher than that of FTBUT123, FTBUT12, FTBUT1 and FTBUTmin in the OSDI criteria and higher than that of FTBUT1 and FTBUTmin in Schirmer I test and CFS tests. FTBUTmax has a close correlation with OSDI, Schirmer I test and CFS, and is an effective tool for the DED diagnosis.Entities:
Year: 2021 PMID: 34075199 PMCID: PMC8169885 DOI: 10.1038/s41598-021-91110-9
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Demographics of all participants: descriptive statistics.
| Parameters | Subjects (n = 147) |
|---|---|
| Age (year) | 37.69 ± 8.73 |
| Gender (male : female) | 51: 96 |
| FTBUTmax (second) | 6.78 ± 4.48 |
| FTBUTmin (second) | 5.73 ± 3.79 |
| FTBUT1 (second) | 5.82 ± 4.02 |
| FBUT12 (second) | 5.84 ± 4.06 |
| FTBUT123 (second) | 5.91 ± 4.33 |
| Corneal fluorescein staining | 0.48 ± 0.82 |
| Shirmer I test (mm) | 13.26 ± 10.55 |
| OSDI scores | 16.84 ± 12.28 |
Subjects were shown as mean ± standard deviation.
Figure 1Boxplots of median (95% CI) for the comparison of logarithm transformed FTBUT1, FTBUTmax, FTBUT123, FTBUT12 and FTBUT23 values using one-way ANOVA test. Significant difference was found between FTBUTmax and FTBUT1, FTBUT123, FTBUT12, FTBUT23 respectively (p = 0.034, 0.038, 0.040 and 0.025, respectively) while no difference was found among other four FTBUT values. *p < 0.05.
Figure 2ROC parameters of FTBUTmax, FTBUTmin, FTBUT1, FTBUT12 and FTBUT123 dividing by Schirmer I test (A), OSDI scores (B) or CFS (C) respectively.
ROC analysis including cutoff point, sensitivity and specificity of different FTBUT values in diagnosing DED.
| FTBUT values | AUROC (95%CI) | Cutoff point(s) | Sensitivity | Specificity | Youden Index | |
|---|---|---|---|---|---|---|
| Less than 10 mm in Schirmer I test | FTBUTmax | 0.792 (0.717–0.854) | 0.6833 | 0.730 | 0.726 | 0.456 |
| FTBUTmin | 0.735 (0.656–0.804) | 0.7551 | 0.608 | 0.767 | 0.375 | |
| FTBUT1 | 0.775 (0.699–0.840) | 0.6459 | 0.743 | 0.699 | 0.442 | |
| FTBUT12 | 0.783 (0.708–0.847) | 0.7474 | 0.743 | 0.712 | 0.456 | |
| FTBUT123 | 0.810 (0.737–0.870) | 0.6911 | 0.716 | 0.781 | 0.497 | |
| More than 13 points in OSDI score | FTBUTmax | 0.747 (0.669–0.815) | 0.8404 | 0.856 | 0.594 | 0.449 |
| FTBUTmin | 0.695 (0.614–0.768) | 0.8274 | 0.879 | 0.531 | 0.411 | |
| FTBUT1 | 0.717 (0.637–0.788) | 0.8299 | 0.783 | 0.609 | 0.393 | |
| FTBUT12 | 0.725 (0.645–0.795) | 0.8357 | 0.645 | 0.795 | 0.426 | |
| FTBUT123 | 0.734 (0.626–0.780) | 0.8420 | 0.880 | 0.550 | 0.426 | |
| More than 0 point in corneal fluorescein staining | FTBUTmax | 0.756 (0.673–0.818) | 0.5453 | 0.588 | 0.802 | 0.390 |
| FTBUTmin | 0.700 (0.619–0.773) | 0.5575 | 0.529 | 0.792 | 0.321 | |
| FTBUT1 | 0.712 (0.632–0.784) | 0.5211 | 0.471 | 0.875 | 0.346 | |
| FTBUT12 | 0.740 (0.661–0.809) | 0.5557 | 0.588 | 0.792 | 0.380 | |
| FTBUT123 | 0.763 (0.690–0.832) | 0.4370 | 0.549 | 0.885 | 0.434 |
FTBUT values were all undertaken logarithmic transformation.
Comparison of p values of ROC analysis among FTBUT types.
| Less than 10 mm in Schirmer I test | More than 13 points in OSDI score | More than 1 point in corneal fluorescein staining | |
|---|---|---|---|
| FTBUT1-FTBUTmax | 0.011* | 0.018* | 0.004** |
| FTBUT1-FTBUT123 | 0.001** | 0.125 | 0.003** |
| FTBUT1-FTBUTmin | 0.002** | 0.139 | 0.350 |
| FTBUT1-FTBUT12 | 0.337 | 0.374 | < 0.001*** |
| FTBUTmax-FTBUT123 | 0.006** | 0.037* | 0.113 |
| FTBUTmax-FTBUTmin | < 0.001*** | 0.002** | < 0.001*** |
| FTBUTmax-FTBUT12 | 0.256 | 0.005** | 0.055 |
| FTBUT123-FTBUTmin | < 0.001*** | 0.006** | < 0.001*** |
| FTBUT123-FTBUT12 | 0.011* | 0.028* | 0.049* |
| FTBUTmin-FTBUT12 | 0.001** | 0.019* | < 0.001*** |
p values were calculated through Medcalc. *p < 0.05, ** p < 0.01, ***p < 0.001.
Correlations between FTBUT values and other dry eye examinations.
| FTBUT values | R | ||
|---|---|---|---|
| Schirmer I test | FTBUTmax-Schirmer I test | − 0.536 | < 0.001 |
| FTBUTmin-Schirmer I test | − 0.463 | < 0.001 | |
| FTBUT1-Schirmer I test | − 0.517 | < 0.001 | |
| FTBUT12-Schirmer I test | − 0.522 | < 0.001 | |
| FTBUT123-Schirmer I test | − 0.556 | < 0.001 | |
| More than 13 points in OSDI score | FTBUTmax-OSDI | − 0.533 | < 0.001 |
| FTBUTmin-OSDI | − 0.357 | < 0.001 | |
| FTBUT1-OSDI | − 0.440 | < 0.001 | |
| FTBUT12-OSDI | − 0.450 | < 0.001 | |
| FTBUT123-OSDI | − 0.483 | < 0.001 | |
| More than 0 point in corneal fluorescein staining | FTBUTmax-CFS | − 0.289 | < 0.001 |
| FTBUTmin-CFS | − 0.244 | < 0.001 | |
| FTBUT1-CFS | − 0.260 | < 0.001 | |
| FTBUT12-CFS | − 0.287 | < 0.001 | |
| FTBUT123-CFS | − 0.307 | < 0.001 |
Numbers and percentage of each FTBUT reading being the FTBUTmax value.
| FTBUT | First FTBUT | Second FTBUT | Third FTBUT |
|---|---|---|---|
| Second(s) | 5.73 ± 3.79 | 5.91 ± 4.43 | 5.86 ± 4.27 |
| Percentage of being FTBUTmax value (%) | 31 (21.1%) | 62 (42.2%) | 54 (36.7%) |
Parameters were presented as mean ± SD.