Reliability of a new modified tear breakup time method: dry tear breakup time.

Kyung Tae Kim1, Jae-Hyung Kim, Young Tae Kong, Ju Byung Chae, Sungmin Hyung.   

Abstract

BACKGROUND: Tear breakup time (TBUT) is a useful technique for diagnosing dry eye disease (DED). The conventional method of measuring TBUT using fluorescein strips adds supplemental normal saline (NS) to the tear film (wet tear breakup time, WBUT) but does not represent the actual state of the tear film. We introduced a new TBUT method-dry tear breakup time (DBUT)-and investigated its reliability.
METHODS: We included DED patients with mild symptoms and a Schirmer test of 6 mm or more. Patients using tear substitutes and/or suffering from Sjogren's syndrome were excluded. For measuring DBUT, 1 μl of 5 % fluorescein solution was instilled on the end of an applicator using a micropipette. Once the fluorescein solution was dry, the applicator was sterilized using ethylene oxide gas, and the dried fluorescein was applied to the lower palpebral conjunctiva without supplemental NS. Agreement between the two tests and their sensitivity and specificity were analyzed.
RESULTS: The average age of the patients was 32.1 ± 9.7 years (n = 124). The DBUT was lower than the WBUT, with a mean difference of -0.63 s. Both tests had a low statistically significant correlation with the Ocular Surface Disease Index. When the basis of definite diagnosis for DED was over grade 1 on the Oxford schema of staining, the cutoff value for the WBUT was 4.48 s and the sensitivity and specificity were 0.790 and 0.548 respectively. The area under the receiver operating characteristic (AUROC) curve was 0.609 (95 % confidence interval (CI): 0.517-0.695). When the cutoff value was 3.5 s for the DBUT, the sensitivity and specificity were 0.726 and 0.694 respectively, and the AUROC curve was 0.724 (95 % CI: 0.637-0.801).
CONCLUSIONS: DBUT had a higher correlation with symptoms than the conventional WBUT. When DED was diagnosed with corneal or conjunctival staining based on the Oxford schema of staining, DBUT had a better accuracy than the conventional WBUT. DBUT may replace WBUT after confirming studies, especially when surface damage is to be detected as opposed to tear flow or symptoms.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26092632     DOI: 10.1007/s00417-015-3080-5

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  17 in total

1.  Survey of preferred tests for diagnosis of the tear film and dry eye.

Authors:  D R Korb
Journal:  Cornea       Date:  2000-07       Impact factor: 2.651

2.  Optical and visual impact of tear break-up in human eyes.

Authors:  R Tutt; A Bradley; C Begley; L N Thibos
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-12       Impact factor: 4.799

3.  Comparison of fluorescein break-up time measurement reproducibility using standard fluorescein strips versus the Dry Eye Test (DET) method.

Authors:  D R Korb; J V Greiner; J Herman
Journal:  Cornea       Date:  2001-11       Impact factor: 2.651

4.  Importance of the lipid layer in human tear film stability and evaporation.

Authors:  J P Craig; A Tomlinson
Journal:  Optom Vis Sci       Date:  1997-01       Impact factor: 1.973

Review 5.  Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes.

Authors:  M A Lemp
Journal:  CLAO J       Date:  1995-10

6.  Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear-film disorders known to cause ocular irritation.

Authors:  S C Pflugfelder; S C Tseng; O Sanabria; H Kell; C G Garcia; C Felix; W Feuer; B L Reis
Journal:  Cornea       Date:  1998-01       Impact factor: 2.651

7.  Tear film osmolarity: determination of a referent for dry eye diagnosis.

Authors:  Alan Tomlinson; Santosh Khanal; Kanna Ramaesh; Charles Diaper; Angus McFadyen
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-10       Impact factor: 4.799

8.  The European Community Study Group on diagnostic criteria for Sjögren's syndrome. Sensitivity and specificity of tests for ocular and oral involvement in Sjögren's syndrome.

Authors:  C Vitali; H M Moutsopoulos; S Bombardieri
Journal:  Ann Rheum Dis       Date:  1994-10       Impact factor: 19.103

9.  Prevalence of dry eye among an elderly Chinese population in Taiwan: the Shihpai Eye Study.

Authors:  Pei-Yu Lin; Su-Ying Tsai; Ching-Yu Cheng; Jorn-Hon Liu; Pesus Chou; Wen-Ming Hsu
Journal:  Ophthalmology       Date:  2003-06       Impact factor: 12.079

Review 10.  Methodologies to diagnose and monitor dry eye disease: report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007).

Authors: 
Journal:  Ocul Surf       Date:  2007-04       Impact factor: 5.033

View more
  4 in total

1.  Reliability of a new modified tear breakup time method: introduction of dry tear breakup time.

Authors:  Kyung Tae Kim; Jae-Hyung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-27       Impact factor: 3.117

2.  Reliability of a new modified tear breakup time method: methodological and statistical issues.

Authors:  Siamak Sabour
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-28       Impact factor: 3.117

3.  Reliability and efficacy of maximum fluorescein tear break-up time in diagnosing dry eye disease.

Authors:  Yujie Mou; Huan Xiang; Lin Lin; Kelan Yuan; Xin Wang; Yaying Wu; Jinjin Min; Xiuming Jin
Journal:  Sci Rep       Date:  2021-06-01       Impact factor: 4.379

4.  Meibomian gland features in a Norwegian cohort of patients with primary Sjögren´s syndrome.

Authors:  Xiangjun Chen; Øygunn Aass Utheim; Jiaxin Xiao; Muhammed Yasin Adil; Aleksandar Stojanovic; Behzod Tashbayev; Janicke Liaaen Jensen; Tor Paaske Utheim
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.